Artificial intelligence (AI) has shown promising results in digestive endoscopy, especially in capsule endoscopy (CE). However, some physicians still have some difficulties and fear the advent of this technology. We aimed to evaluate the perceptions and current sentiments toward the use of AI in CE. An online survey questionnaire was sent to an audience of gastroenterologists. In addition, several European national leaders of the International CApsule endoscopy REsearch (I CARE) Group were asked to disseminate an online survey among their national communities of CE readers (CER). The survey included 32 questions regarding general information, perceptions of AI, and its use in daily life, medicine, endoscopy, and CE. Among 380 European gastroenterologists who answered this survey, 333 (88%) were CERs. The mean average time length of experience in CE reading was 9.9 years (0.5–22). A majority of CERs agreed that AI would positively impact CE, shorten CE reading time, and help standardize reporting in CE and characterize lesions seen in CE. Nevertheless, in the foreseeable future, a majority of CERs disagreed with the complete replacement all CE reading by AI. Most CERs believed in the high potential of AI for becoming a valuable tool for automated diagnosis and for shortening the reading time. Currently, the perception is that AI will not replace CE reading.
The development of new capsules now allows endoscopic diagnosis in all segments of the gastrointestinal tract and comes with new needs for differentiated preparation regimens. Although the literature is steadily increasing, the results of the conducted trials on preparation are sometimes conflicting. The ingestion of simethicone before gastric and small bowel capsule endoscopy for prevention of air bubbles is established. The value of a lavage before small bowel capsule endoscopy (SBCE) is recommended, although not supported by all studies. Ingestion in the morning before the procedure seems useful for the improvement of mucosa visualization. Lavage after swallowing of the capsule seems to improve image quality, and in some studies also diagnostic yield. Prokinetics has been used with first generation capsules to shorten gastric transit time and increase the rate of complete small bowel visualization. With the massively prolonged battery capacity of the new generation small bowel capsules, prokinetics are only necessary in significantly delayed gastric emptying as documented by a real-time viewer. Lavage is crucial for an effective colon capsule or pan-intestinal capsule endoscopy. Mainly high or low volume polyethylene glycol (PEG) is used. Apart from achieving optimal cleanliness, propulsion of the capsule by ingested boosts is required to obtain a complete passage through the colon within the battery lifetime. Boosts with low volume sodium picosulfate (NaP) or diatrizoate (gastrografin) seem most effective, but potentially have more side effects than PEG. Future research is needed for more patient friendly but effective preparations, especially for colon capsule and pan-intestinal capsule endoscopy.
(1) Background: Villous atrophy is an indication for small bowel capsule endoscopy (SBCE). However, SBCE findings are not described uniformly and atrophic features are sometimes not recognized; (2) Methods: The Delphi technique was employed to reach agreement among a panel of SBCE experts. The nomenclature and definitions of SBCE lesions suggesting the presence of atrophy were decided in a core group of 10 experts. Four images of each lesion were chosen from a large SBCE database and agreement on the correspondence between the picture and the definition was evaluated using the Delphi method in a broadened group of 36 experts. All images corresponded to histologically proven mucosal atrophy; (3) Results: Four types of atrophic lesions were identified: mosaicism, scalloping, folds reduction, and granular mucosa. The core group succeeded in reaching agreement on the nomenclature and the descriptions of these items. Consensus in matching the agreed definitions for the proposed set of images was met for mosaicism (88.9% in the first round), scalloping (97.2% in the first round), and folds reduction (94.4% in the first round), but granular mucosa failed to achieve consensus (75.0% in the third round); (4) Conclusions: Consensus among SBCE experts on atrophic lesions was met for the first time. Mosaicism, scalloping, and folds reduction are the most reliable signs, while the description of granular mucosa remains uncertain.