Juozas Bielskus

Dr. Juozas Bielskus

Department of Building Energetics
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016 in Energy Procedia
Verified
Journal Article
Open access
KJKarolis Januševičius
Karolis Januševičius
Giedrė StreckienėGiedrė Streckienė
Giedrė Streckienė
Juozas BielskusJuozas Bielskus
Juozas Bielskus
VMVytautas Martinaitis
Vytautas Martinaitis
Due to the rising demand for high comfort standards and efficient energy use, heat pumps and solar technologies have drawn a great deal of attention as means through which significant energy reductions can be achieved. During the last decade, a number of investigations have been conducted on the design and modelling of different heat pump systems. This paper examines the performance of a solar assisted air source heat pump (ASHP) system for cold climate. The study compares the operation of a stand-alone ASHP against the solar assisted ASHP. The experimental measurements are used to test the performance of the ASHP system in different operating conditions. In addition, using TRNSYS (Transient Systems Simulation) software, simulation models were developed. The simulations using TRNSYS are compared to experimental data. Validation results for system modes of operation are included which demonstrate good conformity between model and experimental performance

12 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
TKTomas Kropas
Tomas Kropas
Giedrė StreckienėGiedrė Streckienė
Giedrė Streckienė
Juozas BielskusJuozas Bielskus
Juozas Bielskus
The application of heat pumps in the heating systems of buildings in the cold or transitional season is becoming an increasingly common practice not only in Lithuania but in other countries as well. Due to the growing popularity of air-to-air or air-to-water heat pumps in the building sector, the problem of the evaporator heat exchanger freezing is also becoming more and more relevant. As the outdoor temperature drops, so does the heat pump’s coefficient of performance (COP) for heating. The freezing of the evaporator surface increases the energy consumption of the system, has a negative effect on heat exchange, distorts the normal operating cycle of the heat pump and the energy is wasted for defrosting processes. This article describes the experimental investigation of an air-to-water heat pump, presents the results obtained during the experiments and their interfaces. The experiments were carried out during the transitional/cold season. It was found that frost formation on the evaporator started when the outdoor temperature was <3.5 °C and the relative humidity reached 88%. The defrosting cycle took an average of 5 min. The impact of the evaporator freezing on the operation and COP of the heat pump was assessed.

1 October 2018 in Applied Thermal Engineering
Verified
Journal Article
Closed access
VMVytautas Martinaitis
Vytautas Martinaitis
Giedrė StreckienėGiedrė Streckienė
Giedrė Streckienė
ABAudrius Bagdanavicius
Audrius Bagdanavicius
Juozas BielskusJuozas Bielskus
Juozas Bielskus

8 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
RDRasa Dziugaite-Tumeniene
Rasa Dziugaite-Tumeniene
RMRūta Mikučionienė
Rūta Mikučionienė
Giedrė StreckienėGiedrė Streckienė
Giedrė Streckienė
Juozas BielskusJuozas Bielskus
Juozas Bielskus
Calibration of the energy model of a building is one of the essential tasks required to determine the efficiency of building management systems, and both their own and other systems’ improvement potential. In order to make the building energy model as accurate as possible, it is necessary to collect comprehensive data on its operation and sometimes to assess the missing information. This paper represents the process of developing an energy model for an administrative building and its calibration procedure, using detailed long-term measurement and building management system (BMS) data. Indoor air temperature, CO₂ concentration, and relative humidity were experimentally measured and evaluated separately. Such dual application of data reduces the inaccuracy of the assumptions made and assesses the model’s accuracy. The DesignBuilder software developed the building model. During the development of the model, it was observed that the actual energy consumption needs to be assessed, as the assumptions made during the design about the operation and management of HVAC systems often do not coincide with the actual situation. After integrating BMS information on HVAC management into the building model, the resulting discrepancy between the model results and the actual heat consumption was 6.5%. Such a model can be further used to optimize management decisions and assess energy savings potential.

3 April 2019 in Entropy
Verified
Journal Article
Open access
PDF file
Giedrė StreckienėGiedrė Streckienė
Giedrė Streckienė
VMVytautas Martinaitis
Vytautas Martinaitis
Juozas BielskusJuozas Bielskus
Juozas Bielskus
The continuous energy transformation processes in heating, ventilation, and air conditioning systems of buildings are responsible for 36% of global final energy consumption. Tighter thermal insulation requirements for buildings have significantly reduced heat transfer losses. Unfortunately, this has little effect on energy demand for ventilation. On the basis of the First and the Second Law of Thermodynamics, the concepts of entropy and exergy are applied to the analysis of ventilation air handling unit (AHU) with a heat pump, in this paper. This study aims to develop a consistent approach for this purpose, taking into account the variations of reference temperature and temperatures of working fluids. An analytical investigation on entropy generation and exergy analysis are used, when exergy is determined by calculating coenthalpies and evaluating exergy flows and their directions. The results show that each component of the AHU has its individual character of generated entropy, destroyed exergy, and exergy efficiency variation. However, the evaporator of the heat pump and fans have unabated quantities of exergy destruction. The exergy efficiency of AHU decreases from 45–55% to 12–15% when outdoor air temperature is within the range of −30 to +10 °C, respectively. This helps to determine the conditions and components of improving the exergy efficiency of the AHU at variable real-world local climate conditions. The presented methodological approach could be used in the dynamic modelling software and contribute to a wider application of the Second Law of Thermodynamics in practice.

5 May 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AFAnton Frik
Anton Frik
Juozas BielskusJuozas Bielskus
Juozas Bielskus
RDRasa Dziugaite-Tumeniene
Rasa Dziugaite-Tumeniene
VMVioleta Motuziene
Violeta Motuziene
Air-to-air heat pumps are used in today’s ventilation systems increasingly often as they provide heating and cooling for buildings. The energy transformation modes of these units are subject to constant change due to the varying outdoor air state, including temperature and humidity. When choosing how to operate and control energy transformers, it is important to be able to adapt effectively to the changing outside air conditions. Nowadays, modern commercial heat pumps offer two levels of control flexibility: a compressor with a variable speed and an electronic expansion valve. This combination of control elements has boosted the seasonal energy efficiency of heat pumps. For a long time, cycle control possibilities have been dominated by electronic controls. The authors of this paper aim to present an additional element to the traditional heat pump controls, which provides a third level of control over the cycle. To achieve the objective, experimental investigations of a heat pump integrated into a ventilation unit have been carried out under real-life conditions. The experiments involved varying the operating modes of the unit by adjusting the compressor speed, the position of the expansion valve, and the volume of the system loop. The study examined the performance characteristics of the heat pump and found that the performance of a variable-volume heat pump is comparable to that of a conventionally operated typical constant-volume heat pump system. In addition, the study found that by adding a third level of volume control to the active heating circuit, in combination with conventional controls, the heat pump’s heat output range could be extended by 69.62%. The study determined the variation of the heat pump cycle in the p-h diagram with the variation of the loop volume. The benefits and drawbacks of a heat pump with a variable-volume loop are discussed in this study.