Audrius Bagdanavicius

Dr. Audrius Bagdanavicius

School of Engineering, University of Leicester, University road, Leicester LE1 7RH, UK
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in Applied Energy
Verified
Journal Article
Open access
XLXuezhi Liu
Xuezhi Liu
JWJianzhong Wu
Jianzhong Wu
NJNick Jenkins
Nick Jenkins
ABAudrius Bagdanavicius
Audrius Bagdanavicius
Energy supply systems are usually considered as individual sub-systems with separate energy vectors. However, the use of Combined Heat and Power (CHP) units, heat pumps and electric boilers creates linkages between electricity and heat networks. Two combined analysis methods were developed to investigate the performance of electricity and heat networks as an integrated whole. These two methods were the decomposed and integrated electrical-hydraulic-thermal calculation techniques in the forms of power flow and simple optimal dispatch. Both methods were based on models of the electrical network, hydraulic and thermal circuits, and the coupling components, focusing on CHP units and circulation pumps. A case study of Barry Island electricity and district heating networks was conducted, showing how both electrical and heat demand in a self-sufficient system (no interconnection with external systems) were met using CHP units. The comparison showed that the integrated method requires less iteration than the decomposed method

1 August 2013 in Energy
Verified
Journal Article
Closed access
MPMarouf Pirouti
Marouf Pirouti
ABAudrius Bagdanavicius
Audrius Bagdanavicius
Janake EkanayakeJanake Ekanayake
Janake Ekanayake
JWJianzhong Wu
Jianzhong Wu
NJNick Jenkins
Nick Jenkins

1 January 2014 in Energy Conversion and Management
Verified
Journal Article
Open access
ABAudrius Bagdanavicius
Audrius Bagdanavicius
NJNick Jenkins
Nick Jenkins
The potential for using heat generated during the compression stage of a Compressed Air Energy Storage system was investigated using exergy and exergoeconomic analysis. Two Compressed Air Energy Storage systems were analysed: Compressed Air Energy Storage (CAES) and Compressed Air Energy Storage combined with Thermal Storage (CAES-TS) connected to a district heating network. The maximum output of the CAES was 100 MWe and the output of the CAES-TS was 100 MWe and 105 MWth. The study shows that 308 GW h/year of electricity and 466 GW h/year of fuel are used to generate 375 GW h/year of electricity. During the compression of air 289 GW h/year of heat is generated, which is wasted in the CAES and used for district heating in the CAES-TS system. Energy efficiency of the CAES system was around 48% and the efficiency of CAES-TS was 86%. Exergoeconomic analysis shows that the exergy cost of electricity generated in the CAES was 13.89 ¢/kW h, and the exergy cost of electricity generated in the CAES-TS was 11.20 ¢/kW h. The exergy cost of heat was 22.24 ¢/kW h in the CAES-TS system. The study shows that CAES-TS has the potential to be used both as energy storage and heat source and could be a useful tool for balancing overall energy demand and supply. © 2013 Elsevier Ltd. All rights reserved.Peer-reviewedPost-prin

1 January 2014 in Energy Procedia
Verified
Journal Article
Open access
XLXuezhi Liu
Xuezhi Liu
NJNick Jenkins
Nick Jenkins
JWJianzhong Wu
Jianzhong Wu
ABAudrius Bagdanavicius
Audrius Bagdanavicius
The use of Combined Heat and Power (CHP) units, heat pumps and electric boilers increases the linkages between electricity and heat networks. Two combined analysis methods were developed to investigate the performance of electricity and heat networks as an integrated whole. These methods were based on models of electrical power flow and hydraulic and thermal circuits together with their coupling components, focusing on CHP units and circulation pumps. These two methods were the decomposed and integrated electrical-hydraulic-thermal calculation techniques in the forms of power flow and simple optimal dispatch. The comparison showed that the integrated method requires fewer iterations than the decomposed method. A case study of Barry Island electricity and district heating networks was conducted, showing how both electrical and heat demand in a self-sufficient system (no interconnection with external systems) were met using CHP units

1 September 2012 in Energy
Verified
Journal Article
Closed access
ABAudrius Bagdanavicius
Audrius Bagdanavicius
NJNick Jenkins
Nick Jenkins
GHGeoffrey Paul Hammond
Geoffrey Paul Hammond

1 February 2013 in Applied Energy
Verified
Journal Article
Closed access
ABAudrius Bagdanavicius
Audrius Bagdanavicius
NJNick Jenkins
Nick Jenkins