Musaddaq Azeem

Dr. Musaddaq Azeem

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2022 in Polymers
Verified
Journal Article
Open access
PDF file
AAAzam Ali
Azam Ali
Fiaz HussainFiaz Hussain
Fiaz Hussain
MTMuhammad Farrukh Tahir
Muhammad Farrukh Tahir
MAMajid Ali
Majid Ali
Muhammad Zaman KhanMuhammad Zaman Khan
Muhammad Zaman Khan
MAMusaddaq Azeem
Musaddaq Azeem
Conventional conductive homopolymers such as polypyrrole and poly-3,4-ethylenedioxythiophene (PEDOT) have poor mechanical properties, for the solution to this problem, we tried to construct hybrid composites with higher electrical properties coupled with high mechanical strength. For this purpose, Kevlar fibrous waste, conductive carbon particles, and epoxy were used to make the conductive composites. Kevlar waste was used to accomplish the need for economics and to enhance the mechanical properties. At first, Kevlar fibrous waste was converted into a nonwoven web and subjected to different pretreatments (chemical, plasma) to enhance the bonding between fiber-matrix interfaces. Similarly, conductive carbon particles were converted into nanofillers by the action of ball milling to make them homogeneous in size and structure. The size and morphological structures of ball-milled particles were analyzed by Malvern zetasizer and scanning electron microscopy. In the second phase of the study, the conductive paste was made by adding the different concentrations of ball-milled carbon particles into green epoxy. Subsequently, composite samples were fabricated via a combination of prepared conductive pastes and a pretreated Kevlar fibers web. The influence of different concentrations of carbon particles into green epoxy resin for electrical conductivity was studied. Additionally, the electrical conductivity and electromagnetic shielding ability of conductive composites were analyzed. The waveguide method at high frequency (i.e., at 2.45 GHz) was used to investigate the EMI shielding. Furthermore, the joule heating response was studied by measuring the change in temperature at the surface of the conductive composite samples, while applying a different range of voltages. The maximum temperature of 55 °C was observed when the applied voltage was 10 V. Moreover, to estimate the durability and activity in service the ageing performance (mechanical strength and moisture regain) of developed composite samples were also analyzed.

17 December 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
MAMusaddaq Azeem
Musaddaq Azeem
Nesrine AmorNesrine Amor
Nesrine Amor
MKMuhammad Kashif
Muhammad Kashif
WTWaqas Ali Tabassum
Waqas Ali Tabassum
Muhammad Tayyab NomanMuhammad Tayyab Noman
Muhammad Tayyab Noman
The United Kingdom’s (UK) retrofit revolution is at a crossroads and the efficacy of retrofit interventions is not solely a function of insulation thickness. To truly slash emissions and lift households out of fuel poverty, we must solve the persistent problem of thermal bridging (TB), i.e., the hidden flaws that cause heat to escape, dampness to form, and well-intentioned retrofits to fail. This review moves beyond basic principles to spotlight the emerging tools and transformative strategies to make a difference. We explore the role of advanced modelling techniques, including finite element analysis (FEA), in pinpointing thermal and moisture-related risks, and how emerging materials like vacuum-insulated panels (VIPs) offer high-performance solutions in tight spaces. Crucially, we demonstrate how an integrated fabric-first approach, guided by standards like PAS 2035, is essential to manage moisture, ensure durability, and deliver the comfortable, low-energy homes the UK desperately needs. Therefore, achieving net-zero targets is critically dependent on the systematic upgrade of the building envelope, with the mitigation of TB representing a fundamental prerequisite. The EnerPHit approach applies a rigorous fabric-first methodology to eliminate TB and significantly reduce the building’s overall heat demand. This reduction enables the use of a compact heating system that can be efficiently powered by renewable energy sources, such as solar photovoltaic (PV). Moreover, this review employs a systematic literature synthesis to critically evaluate the integration of TB mitigation within the PAS 2035 framework, identifying key technical interdependencies and research gaps in whole-house retrofit methodology. This article provides a comprehensive review of established FEA modelling methodologies, rather than presenting results from original simulations.

28 July 2026 in Polymers
Verified
Journal Article
Open access
PDF file
Muhammad Tayyab NomanMuhammad Tayyab Noman
Muhammad Tayyab Noman
Nesrine AmorNesrine Amor
Nesrine Amor
MAMusaddaq Azeem
Musaddaq Azeem
Fiaz HussainFiaz Hussain
Fiaz Hussain
Fiber–matrix interface engineering plays a decisive role in determining the mechanical performance of fiber-reinforced polymer composites (FRPCs). Despite extensive research on surface modification strategies, translating improvements in interfacial properties into reliable structural performance remains a major challenge. This review critically examines how surface chemistry, interphase architecture, nanomodification, and processing conditions collectively govern load transfer, interfacial shear strength, damage evolution, and overall mechanical behavior. Unlike conventional reviews that primarily summarize modification techniques, this work emphasizes the coupled relationship between interface design and manufacturing, demonstrating that interfacial performance is strongly process-dependent rather than an intrinsic material property. Reported improvements in interfacial metrics are critically evaluated against macroscopic structural performance, revealing persistent limitations arising from dispersion quality, resin rheology, processing defects, and scalability. A multiscale framework is proposed to connect physicochemical modifications with laminate-level failure mechanisms, including delamination, fiber pull-out, and fatigue degradation. The review identifies major research gaps in interphase characterization, standardized evaluation methods, and scalable interface engineering, and outlines future directions based on process-integrated design, predictive modeling, and multifunctional interphases for next-generation composite structures.

17 March 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
MKMuhammad Kashif
Muhammad Kashif
SHSaif Ul Haq
Saif Ul Haq
MAMusaddaq Azeem
Musaddaq Azeem
Hafiz Muhammad Asad AliHafiz Muhammad Asad Ali
Hafiz Muhammad Asad Ali
The high energy consumption in the building sector and the increasing impacts of climate change have necessitated the transition to net-zero-energy buildings (NZEBs), in which energy retrofit strategies play a key role. However, neglecting moisture transport and climatic design while improving energy efficiency often leads to reduced building performance, material deterioration, worse occupant health, and indoor environmental problems. This review examines in detail the basic mechanisms of moisture transport, including diffusion, capillary action, and airborne moisture transport, and illustrates how poor moisture control affects thermal performance and resident health. Additionally, a comparative analysis of the impact of retrofit strategies implemented in different climatic regions on energy efficiency, carbon emission reduction, moisture-related failures and net-zero goals is conducted. At the same time, the need exists to incorporate awareness regarding the adverse effects on the health of occupants. This systematic review analyzed 120 peer-reviewed studies published from 1994 to 2026, covering different climatic regions (e.g., cold, temperate, warm–humid, etc.). The analysis found that the energy savings rates were reported to range from 18% to 45%, while the moisture-related failures in inappropriately retrofitted buildings were observed to increase by up to 32% in some cold regions. This research review provides a comprehensive advisory framework for domestic residents to take remedial steps until retrofit experts gain access in order to prevent health risks from mold and moisture ingress, which can contribute to a healthy lifestyle and a net-zero-energy building.

Verified
Journal Article
Open access
PDF file
Muhammad Tayyab NomanMuhammad Tayyab Noman
Muhammad Tayyab Noman
MAMusaddaq Azeem
Musaddaq Azeem
Nesrine AmorNesrine Amor
Nesrine Amor
Ahmad FrazAhmad Fraz
Ahmad Fraz
MKMuhammad Kashif
Muhammad Kashif
Retrofitting existing buildings has become a critical strategy for reducing energy consumption, improving thermal comfort, and achieving carbon reduction targets in the built environment. Among retrofit measures, wall insulation plays a pivotal role in minimizing heat loss and enhancing building energy efficiency. Conventional insulation materials, although effective, are often associated with high embodied energy, limited recyclability, and environmental concerns. Consequently, bio-based composite materials derived from natural fibers, agricultural residues, and renewable binders have emerged as promising sustainable alternatives. However, the moisture sensitivity of lignocellulosic materials remains a major challenge that can compromise thermal performance, durability, and long-term service life. This review provides a comprehensive and critical assessment of bio-based hydrophobic composite panels for wall insulation in retrofit applications. Unlike previous reviews that have primarily examined bio-based insulation materials, natural-fiber composites, or hydrophobic modifications separately, this study integrates these interconnected research domains within a unified framework. The review systematically examines raw material selection, composite panel manufacturing processes, hydrophobic surface-engineering strategies, thermal and moisture-related performance, durability characteristics, retrofit implementation approaches, and sustainability considerations. The analysis demonstrates that hydrophobic modification significantly reduces moisture uptake, enhances dimensional stability, and preserves thermal-insulation performance under varying environmental conditions. Natural-fiber-based composites, including hemp, flax, jute, bamboo, coconut fiber, and agricultural residues, exhibit competitive thermal conductivity (λ) values while offering reduced environmental impacts compared with conventional insulation materials. Furthermore, the integration of advanced hydrophobic treatments improves resistance to water penetration, biological degradation, and freeze–thaw damage, thereby increasing the long-term reliability of retrofit insulation systems.

4 June 2026 in Polymers
Verified
Journal Article
Open access
PDF file
MAMusaddaq Azeem
Musaddaq Azeem
Nesrine AmorNesrine Amor
Nesrine Amor
MKMuhammad Kashif
Muhammad Kashif
Muhammad Tayyab NomanMuhammad Tayyab Noman
Muhammad Tayyab Noman
Buildings account for a significant share of global energy consumption and carbon emissions, creating an urgent need for advanced energy retrofit technologies. This review critically examines the role of plasma-modified textile polymer materials in improving the energy efficiency and durability of building retrofit systems. Various textile polymers, including polyester (polyethylene terephthalate, PET), polypropylene (PP), polytetrafluoroethylene (PTFE), polyamide (PA), and fiber-reinforced composites, are evaluated in relation to plasma surface engineering approaches, including atmospheric plasma, dielectric barrier discharge (DBD), and plasma jet treatment. Reported studies demonstrate that plasma treatment significantly alters surface morphology and chemistry, resulting in increased surface roughness, enhanced wettability, improved coating adhesion, and superior hydrophobic behavior. Water contact angles increased from approximately 70° to 145° depending on polymer type and plasma conditions, while reflective coating performance improved with solar reflectance enhancements of approximately 10–15%. Plasma-treated reflective roofing and shading textiles also showed reductions in building cooling energy demand of approximately 18–25% and roof temperature decreases of 10–15 °C. Furthermore, plasma-induced surface activation improved durability, ultraviolet (UV) resistance, and weather stability of textile membranes used in facade and roofing applications. The review also discusses industrial challenges related to scalability, plasma aging effects, energy consumption, and long-term performance. Plasma-modified systems demonstrate strong potential for multifunctional, lightweight, and sustainable building envelope technologies for future energy-efficient construction.