Nicolas Haelewijn

Mr. Nicolas Haelewijn

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2023 in Heliyon
Verified
Journal Article
Open access
NHNicolas Haelewijn
Nicolas Haelewijn
JPJean-Louis Peters-Dickie
Jean-Louis Peters-Dickie
FSFilip Staes
Filip Staes
EVEvie Vereecke
Evie Vereecke
KDKevin Deschamps
Kevin Deschamps
Ultrasonography can discriminate between intrinsic and extrinsic foot muscle properties and has therefore gained considerable popularity as an indirect strength evaluation. However, an overview on the use of ultrasound for assessing intrinsic foot musculature (IFM) is currently lacking. What is the current evidence regarding (1) 2D ultrasonography protocols and its reliability? (2) Reference values for cross-sectional area and dorso-plantar thickness evaluation in asymptomatic and symptomatic persons? The PRISMA guidelines were used to conduct this systematic review. Eight databases (PubMed, Embase, Web of Science, Cochrane Library, Scopus, CINAHL, SPORTDiscus and EuropePMC) were searched up to November 1, 2021. Studies reporting quantitative 2D ultrasound findings of the intrinsic foot muscles with no limitation to sex, BMI, ethnicity or physical activity were included. Studies were assessed for methodological quality using the Downs and Black checklist. Fifty-three studies were retained. Protocols showed an overall good to great reliability, suggesting limits of agreement between 8 and 30% of relative muscle size with minimal detectable changes varying from 0.10 to 0.29 cm2 for cross-sectional area and 0.03–0.23 cm for thickness. Reference values are proposed for both cross-sectional area and thickness measurements of the abductor hallucis, flexor digitorum brevis, flexor hallucis brevis and quadratus plantae in asymptomatic persons. This could not be performed in the symptomatic studies due to a limited number of relevant studies addressing the symptomatic population, therefore a clinical overview is outlined. Clinically, IFM properties have been studied in ten distinct pathological conditions, predominantly pointing towards decreased muscle properties of the abductor hallucis. We provide a clear and comprehensive overview of the literature regarding 2D ultrasonography of the IFM, making the available evidence more accessible to decision makers and researchers.

1 January 2025 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
NHNicolas Haelewijn
Nicolas Haelewijn
JPJean-Louis Peters-Dickie
Jean-Louis Peters-Dickie
RRRoel de Ridder
Roel de Ridder
KDKevin Deschamps
Kevin Deschamps
DCDetrembleur Christine
Detrembleur Christine
VSValentien Spanhove
Valentien Spanhove
Background: Quantitative ultrasound imaging is a popular technique to assess the structural properties of the intrinsic and extrinsic foot muscles. Although several studies examined test-retest reliability, specific gaps remain in assessing inter-rater reliability, particularly distinguishing between image acquisition and muscle measurement. Additionally, these studies utilized equipment that may not be generalizable across both clinical and research settings and often involved small sample sizes without prior sample size calculations. This study aimed to investigate test-retest reliability as well as global and measurement-based inter-rater reliability (MIRR) using a low-end ultrasound device to measure intrinsic and extrinsic foot muscle sizes. Methods: This prospective reliability study included 21 active individuals. Five intrinsic muscles [abductor hallucis (AbH), flexor digitorum brevis (FDB), flexor hallucis brevis (FHB), quadratus plantae (QP), abductor digiti minimi (AbDM)], and three extrinsic muscles [peroneal (PER), flexor digitorum longus, tibialis anterior (TA)] were scanned. Three investigators independently acquired images on two occasions and measured cross-sectional area (CSA) and thickness in September and October 2023. Participants were assessed either at the Musculoskeletal Research Group laboratory (University of Leuven, Bruges) or in the Rehabilitation Sciences laboratory (Ghent University hospital). Test-retest (same investigator, one week in between), global inter-rater (each investigator measures own image set) and MIRR (three investigators measure one image set) was performed following intra-class correlation, standard error of the measurement (SEM) and coefficient of variation. Results: Test-retest reliability showed intraclass-correlation coefficients of 0.60–0.88 for the FDB and 0.38–0.73 for the TA. SEM ranged from 0.16 to 0.41 cm2 (CSA) and from 0.05 to 0.31 cm (thickness) for the intrinsic, while they ranged from 0.19 to 1.13 cm2 and from 0.12 to 0.44 cm for the extrinsic muscles. Global inter-rater correlation coefficients varied between 0.4 and 0.8 for the AbH and FDB. Measurement based inter-rater correlation coefficient varied between 0.50 and 0.96 for AbH, FDB, TA and PER muscles. SEM ranged from 0.14 to 0.89 cm2 (CSA) and from 0.07 to 0.24 cm (thickness) for the intrinsic, while they ranged from 0.29 to 0.85 cm2 (CSA) and from 0.12 to 0.51 cm (thickness) for the extrinsic muscles. Coefficients of variations were between 4% and 34%. For test-retest, they were consistently ≤10% for AbH thickness, FDB CSA, FHB and TA. FDB coefficients of variation were ≤10% across all inter-rater reliabilities. Conclusions: Most muscles demonstrated moderate to excellent test-retest reliability using a portable ultrasound device, supporting its generalizability. However, the greater variability in global inter-rater reliability suggests substantial variation during image acquisition. The same clinician should perform pre-intervention and follow-up assessments to minimize errors. If different clinicians are involved, caution is needed when comparing measurements.

17 November 2024 in Clinical Biomechanics
Verified
Journal Article
Closed access
NHNicolas Haelewijn
Nicolas Haelewijn
AGAlice Gelaude
Alice Gelaude
LALize Allemeersch
Lize Allemeersch
FSFilip Staes
Filip Staes
EVEvie Vereecke
Evie Vereecke
KDKevin Deschamps
Kevin Deschamps

NHNicolas Haelewijn
Nicolas Haelewijn
SLSébastien Lobet
Sébastien Lobet
ADAn Van Damme
An Van Damme
PDPierre-Louis Docquier
Pierre-Louis Docquier
MEMaarten Eerdekens
Maarten Eerdekens
KDKevin Deschamps
Kevin Deschamps
Ankle joint distraction (AJD) has been described to be a valuable joint-sparing alternative to arthrodesis or arthroplasty; however, clinical endpoints associated to this surgical intervention are lacking. The current case report describes clinical and biomechanical outcome measures of ankle joint distraction in a 14-year-old patient with severe haemophilia A. Because of persistent and incapacitating pain and the poor response to conservative and invasive treatment options, ankle joint distraction was performed in this 14-year-old patient using an external fixator encompassing two Ilizarov full rings in the tibia and a foot ring fixed to the foot by four K-wires. State-of-the-art medical imaging and non-invasive skin marker-based 3D multi-segment foot modelling were performed in a pre- and post-operative stage. From a structural viewpoint, this AJD was a success since it improved and stabilised the osteo-cartilaginous lesions of the ankle. Biomechanical outcome measures associated with the 18-month follow-up were found to be suboptimal, showing an early plantarflexion pattern at the ankle joint during midstance and a tendency towards increased power absorption at the midfoot with peak power absorption being almost two times higher when compared to boys of the same age. From a functional viewpoint, we observed a clear reduction in the patients’ physical activities until one year after AJD. Despite these functional and structural improvements, recurrent painful phenomena, including the development of a complex regional pain syndrome (CRPS) and a stress fracture of the third metatarsal bone, were observed which are probably related with the development of recurrent subchondral oedema.

16 April 2026 in Sensors
Verified
Journal Article
Open access
PDF file
NHNicolas Haelewijn
Nicolas Haelewijn
IDIris Deknudt
Iris Deknudt
MVMarie Vanhaelewyn
Marie Vanhaelewyn
FSFilip Staes
Filip Staes
EVEvie Vereecke
Evie Vereecke
KDKevin Deschamps
Kevin Deschamps
Flatfeet involve a collapse of the medial longitudinal arch, hindfoot valgus, and forefoot abduction. Flexible flatfoot is the most common type and can often be corrected with physiotherapy or orthotics. While some individuals remain asymptomatic, others develop symptoms for reasons that are not fully understood. This cross-sectional study compared plantar pressure distributions in 16 adults with asymptomatic and 16 with symptomatic flexible flatfeet (FPI-6 > 6; navicular drop > 5 mm), using a resistive-sensor-equipped pressure plate during walking and heel-strike running. During walking, symptomatic participants showed significantly higher total and peak forces at metatarsal 5 (p ≤ 0.003), and the midfoot (p ≤ 0.02146). The medial heel had significantly lower peak force (p = 0.00147), and metatarsal 4 showed higher peak force (p = 0.02539). Force ratios indicated a more lateralized pressure distribution in the symptomatic group. During heel-strike running, the symptomatic group exhibited higher total and peak forces at the fifth metatarsal, the midfoot, and the first metatarsal, with shorter time to peak force in the midfoot and the medial part of the heel. No significant ratio differences were found during running. Symptomatic individuals adopted a lateralized pressure distribution pattern, contrasting the traditional expectation of medial overload in flatfoot conditions.

25 April 2022 in European Journal of Sport Science
Verified
Journal Article
Closed access
KHKobe C. Houtmeyers
Kobe C. Houtmeyers
MBMichel S. Brink
Michel S. Brink
Werner F. HelsenWerner F. Helsen
Werner F. Helsen
NHNicolas Haelewijn
Nicolas Haelewijn
MHMichiel Hagen
Michiel Hagen
JVJos Vanrenterghem
Jos Vanrenterghem
The rating of perceived exertion method (RPE) allows to describe training intensity in a single value. To better understand the underlying components, the separate rating of perceived breathlessness (RPE‐B) and leg‐muscle exertion (RPE‐L) has been proposed. Here we hypothesised that the separation between the two components may (partly) be determined by the impacts on the lower extremities. In this study, we aimed to experimentally evaluate the differential effect of high versus low impact running and jumping on RPE‐B and RPE‐L in team sport activities by manipulating the movement strategy (heel strike and passive landing pattern versus forefoot strike and active landing pattern). Eighteen recreational team sport players participated in two submaximal tests consisting of a sequence of running and jumping bouts, whilst ground reaction forces (GRF) were collected. RPE‐B and RPE‐L data were collected after each bout using the CR100 scale. Paired‐samples t‐tests were used to analyse between‐session differences in these variables. GRF analysis showed that absorption mechanics differed considerably between the two sessions. RPE‐L was on average 6.50 AU higher in the low impact session (p = 0.006). However, RPE‐B was also increased by 4.96 AU with low impact (p = 0.009). We conclude that the extent to which the lower extremities are being exposed to high or low impacts does not explain a possible separation between the two RPE types.Highlights The separate rating of the different underlying components of RPE (e.g. variables related to the cardiorespiratory and the muscular system) may provide more insight in the relationship between training load and training outcomes, which likely differs between these components. The findings of this study do not support the idea that the separation in rating between perceived breathlessness (RPE‐B, cardiorespiratory) and leg‐muscle exertion (RPE‐L, muscular) is also rooted in the extent to which musculoskeletal structures in the lower extremities are being exposed to high or low impacts.