Nils Roth

Mr. Nils Roth

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2022 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
MUMartin Ullrich
Martin Ullrich
NRNils Roth
Nils Roth
AKArne Küderle
Arne Küderle
RRRobert Richer
Robert Richer
TGTill Gladow
Till Gladow
Felix KlugeFelix Kluge
Felix Kluge
Falls are an eminent risk for older adults and especially patients with neurodegenerative disorders, such as Parkinson's disease (PD). Recent advancements in wearable sensor technology and machine learning may provide a possibility for an individualized prediction of fall risk based on gait recordings from standardized gait tests or from unconstrained real-world scenarios. However, the most effective aggregation of continuous real-world data as well as the potential of unsupervised gait tests recorded over multiple days for fall risk prediction still need to be investigated. Therefore, we present a data set containing real-world gait and unsupervised 4x10-Meter-Walking-Tests of 40 PD patients, continuously recorded with foot-worn inertial sensors over a period of two weeks. In this prospective study, falls were self-reported during a three-month follow-up phase, serving as ground truth for fall risk prediction. The purpose of this study was to compare different data aggregation approaches and machine learning models for the prospective prediction of fall risk using gait parameters derived either from continuous real-world recordings or from unsupervised gait tests. The highest balanced accuracy of 74.0% (sensitivity: 60.0%, specificity: 88.0%) was achieved with a Random Forest Classifier applied to the real-world gait data when aggregating all walking bouts and days of each participant. Our findings suggest that fall risk can be predicted best by merging the entire two-week real-world gait data of a patient, outperforming the prediction using unsupervised gait tests (68.0% balanced accuracy) and contribute to an improved understanding of fall risk prediction.

7 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MZMarkus Zrenner
Markus Zrenner
AKArne Küderle
Arne Küderle
NRNils Roth
Nils Roth
UJUlf Jensen
Ulf Jensen
BDBurkhard Dümler
Burkhard Dümler
Bjoern EskofierBjoern Eskofier
Bjoern Eskofier
Wearable sensor technology already has a great impact on the endurance running community. Smartwatches and heart rate monitors are heavily used to evaluate runners’ performance and monitor their training progress. Additionally, foot-mounted inertial measurement units (IMUs) have drawn the attention of sport scientists due to the possibility to monitor biomechanically relevant spatio-temporal parameters outside the lab in real-world environments. Researchers developed and investigated algorithms to extract various features using IMU data of different sensor positions on the foot. In this work, we evaluate whether the sensor position of IMUs mounted to running shoes has an impact on the accuracy of different spatio-temporal parameters. We compare both the raw data of the IMUs at different sensor positions as well as the accuracy of six endurance running-related parameters. We contribute a study with 29 subjects wearing running shoes equipped with four IMUs on both the left and the right shoes and a motion capture system as ground truth. The results show that the IMUs measure different raw data depending on their position on the foot and that the accuracy of the spatio-temporal parameters depends on the sensor position. We recommend to integrate IMU sensors in a cavity in the sole of a running shoe under the foot’s arch, because the raw data of this sensor position is best suitable for the reconstruction of the foot trajectory during a stride.

11 October 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
MUMartin Ullrich
Martin Ullrich
AMAnnika Mucke
Annika Mucke
AKArne Küderle
Arne Küderle
NRNils Roth
Nils Roth
TGTill Gladow
Till Gladow
Felix KlugeFelix Kluge
Felix Kluge
Gait tests as part of home monitoring study protocols for patients with movement disorders may provide valuable standardized anchor-points for real-world gait analysis using inertial measurement units (IMUs). However, analyzing unsupervised gait tests relies on reliable test annotations by the patients requiring a potentially error-prone interaction with the recording system. To overcome this limitation, this work presents a novel algorithmic pipeline for the automated detection of unsupervised standardized gait tests from continuous real-world IMU data. In a study with twelve Parkinson’s disease patients, we recorded real-world gait data over two weeks using foot-worn IMUs. During continuous daily recordings, the participants performed series of three consecutive ${4}\times {10}$ -Meters-Walking-Tests ( ${4}\times {10}$ MWTs) at different walking speeds, besides their usual daily-living activities. The algorithm first detected these gait test series using a gait sequence detection algorithm, a peak enhancement pipeline, and subsequence Dynamic Time Warping and then decomposed them into single ${4}\times {10}$ MWTs based on the walking speed. In the evaluation with 419 available gait test series, the detection reached an F1-score of 88.9% and the decomposition an F1-score of 94.0%. A concurrent validity evaluation revealed very good agreement between spatio-temporal gait parameters derived from manually labelled and automatically detected ${4}\times {10}$ MWTs. Our algorithm allows to remove the burden of system interaction from the patients and reduces the time for manual data annotation for researchers. The study contributes to an improved automated processing of real-world IMU gait data and enables a simple integration of standardized tests into continuous long-term recordings. This will help to bridge the gap between supervised and unsupervised gait assessment.

3 June 2021 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
NRNils Roth
Nils Roth
AKArne Küderle
Arne Küderle
MUMartin Ullrich
Martin Ullrich
TGTill Gladow
Till Gladow
FMFranz Marxreiter
Franz Marxreiter
Felix KlugeFelix Kluge
Felix Kluge
Background: To objectively assess a patient’s gait, a robust identification of stride borders is one of the first steps in inertial sensor-based mobile gait analysis pipelines. While many different methods for stride segmentation have been presented in the literature, an out-of-lab evaluation of respective algorithms on free-living gait is still missing. Method: To address this issue, we present a comprehensive free-living evaluation dataset, including 146.574 semi-automatic labeled strides of 28 Parkinson’s Disease patients. This dataset was used to evaluate the segmentation performance of a new Hidden Markov Model (HMM) based stride segmentation approach compared to an available dynamic time warping (DTW) based method. Results: The proposed HMM achieved a mean F1-score of 92.1% and outperformed the DTW approach significantly. Further analysis revealed a dependency of segmentation performance to the number of strides within respective walking bouts. Shorter bouts ( $$< 30$$ < 30 strides) resulted in worse performance, which could be related to more heterogeneous gait and an increased diversity of different stride types in short free-living walking bouts. In contrast, the HMM reached F1-scores of more than 96.2% for longer bouts ( $$> 50$$ > 50 strides). Furthermore, we showed that an HMM, which was trained on at-lab data only, could be transferred to a free-living context with a negligible decrease in performance. Conclusion: The generalizability of the proposed HMM is a promising feature, as fully labeled free-living training data might not be available for many applications. To the best of our knowledge, this is the first evaluation of stride segmentation performance on a large scale free-living dataset. Our proposed HMM-based approach was able to address the increased complexity of free-living gait data, and thus will help to enable a robust assessment of stride parameters in future free-living gait analysis applications.

23 August 2017 in Sensors
Verified
Journal Article
Open access
PDF file
JHJulius Hannink
Julius Hannink
Malte OllenschlägerMalte Ollenschläger
Malte Ollenschläger
Felix KlugeFelix Kluge
Felix Kluge
NRNils Roth
Nils Roth
JKJochen Klucken
Jochen Klucken
Bjoern EskofierBjoern Eskofier
Bjoern Eskofier
Mobile gait analysis systems based on inertial sensing on the shoe are applied in a wide range of applications. Especially for medical applications, they can give new insights into motor impairment in, e.g., neurodegenerative disease and help objectify patient assessment. One key component in these systems is the reconstruction of the foot trajectories from inertial data. In literature, various methods for this task have been proposed. However, performance is evaluated on a variety of datasets due to the lack of large, generally accepted benchmark datasets. This hinders a fair comparison of methods. In this work, we implement three orientation estimation and three double integration schemes for use in a foot trajectory estimation pipeline. All methods are drawn from literature and evaluated against a marker-based motion capture reference. We provide a fair comparison on the same dataset consisting of 735 strides from 16 healthy subjects. As a result, the implemented methods are ranked and we identify the most suitable processing pipeline for foot trajectory estimation in the context of mobile gait analysis.

1 September 2018 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
NRNils Roth
Nils Roth
CMChristine Martindale
Christine Martindale
BEBjoern M. Eskofier
Bjoern M. Eskofier
HGHeiko Gaßner
Heiko Gaßner
ZKZacharias Kohl
Zacharias Kohl
JKJochen Klucken
Jochen Klucken
Wearable sensor systems are of increasing interest in clinical gait analysis. However, little information about gait dynamics of patients under free living conditions is available, due to the challenges of integrating such systems unobtrusively into a patient’s everyday live. To address this limitation, new, fully integrated low power sensor insoles are proposed, to target applications particularly in home-monitoring scenarios. The insoles combine inertial as well as pressure sensors and feature wireless synchronization to acquire biomechanical data of both feet with a mean timing offset of 15.0 μs. The proposed system was evaluated on 15 patients with mild to severe gait disorders against the GAITRite® system as reference. Gait events based on the insoles’ pressure sensors were manually extracted to calculate temporal gait features such as double support time and double support. Compared to the reference system a mean error of 0.06 s ±0.06 s and 3.89 % ±2.61 % was achieved, respectively. The proposed insoles proved their ability to acquire synchronized gait parameters and address the requirements for home-monitoring scenarios, pushing the boundaries of clinical gait analysis.