Arne Küderle

Mr. Arne Küderle

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2023 in The Lancet Digital Health
Verified
Journal Article
Open access
RRRené Raab
René Raab
AKArne Küderle
Arne Küderle
AZAnastasiya Zakreuskaya
Anastasiya Zakreuskaya
ASAriel D Stern
Ariel D Stern
JKJochen Klucken
Jochen Klucken
Bjoern EskofierBjoern Eskofier
Bjoern Eskofier
The European Commission's draft for the European Health Data Space (EHDS) aims to empower citizens to access their personal health data and share it with physicians and other health-care providers. It further defines procedures for the secondary use of electronic health data for research and development. Although this planned legislation is undoubtedly a step in the right direction, implementation approaches could potentially result in centralised data silos that pose data privacy and security risks for individuals. To address this concern, we propose federated personal health data spaces, a novel architecture for storing, managing, and sharing personal electronic health records that puts citizens at the centre-both conceptually and technologically. The proposed architecture puts citizens in control by storing personal health data on a combination of personal devices rather than in centralised data silos. We describe how this federated architecture fits within the EHDS and can enable the same features as centralised systems while protecting the privacy of citizens. We further argue that increased privacy and control do not contradict the use of electronic health data for research and development. Instead, data sovereignty and transparency encourage active participation in studies and data sharing. This combination of privacy-by-design and transparent, privacy-preserving data sharing can enable health-care leaders to break the privacy-exploitation barrier, which currently limits the secondary use of health data in many cases.

18 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
VJVerena Jakob
Verena Jakob
AKArne Küderle
Arne Küderle
Felix KlugeFelix Kluge
Felix Kluge
JKJochen Klucken
Jochen Klucken
Bjoern EskofierBjoern Eskofier
Bjoern Eskofier
Heiko GassnerHeiko Gassner
Heiko Gassner
Digital technologies provide the opportunity to analyze gait patterns in patients with Parkinson’s Disease using wearable sensors in clinical settings and a home environment. Confirming the technical validity of inertial sensors with a 3D motion capture system is a necessary step for the clinical application of sensor-based gait analysis. Therefore, the objective of this study was to compare gait parameters measured by a mobile sensor-based gait analysis system and a motion capture system as the gold standard. Gait parameters of 37 patients were compared between both systems after performing a standardized 5 × 10 m walking test by reliability analysis using intra-class correlation and Bland–Altman plots. Additionally, gait parameters of an age-matched healthy control group (n = 14) were compared to the Parkinson cohort. Gait parameters representing bradykinesia and short steps showed excellent reliability (ICC > 0.96). Shuffling gait parameters reached ICC > 0.82. In a stridewise synchronization, no differences were observed for gait speed, stride length, stride time, relative stance and swing time (p > 0.05). In contrast, heel strike, toe off and toe clearance significantly differed between both systems (p < 0.01). Both gait analysis systems distinguish Parkinson patients from controls. Our results indicate that wearable sensors generate valid gait parameters compared to the motion capture system and can consequently be used for clinically relevant gait recordings in flexible environments.

19 October 2022 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
MUMartin Ullrich
Martin Ullrich
NRNils Roth
Nils Roth
AKArne Küderle
Arne Küderle
RRRobert Richer
Robert Richer
TGTill Gladow
Till Gladow
Felix KlugeFelix Kluge
Felix Kluge
Falls are an eminent risk for older adults and especially patients with neurodegenerative disorders, such as Parkinson's disease (PD). Recent advancements in wearable sensor technology and machine learning may provide a possibility for an individualized prediction of fall risk based on gait recordings from standardized gait tests or from unconstrained real-world scenarios. However, the most effective aggregation of continuous real-world data as well as the potential of unsupervised gait tests recorded over multiple days for fall risk prediction still need to be investigated. Therefore, we present a data set containing real-world gait and unsupervised 4x10-Meter-Walking-Tests of 40 PD patients, continuously recorded with foot-worn inertial sensors over a period of two weeks. In this prospective study, falls were self-reported during a three-month follow-up phase, serving as ground truth for fall risk prediction. The purpose of this study was to compare different data aggregation approaches and machine learning models for the prospective prediction of fall risk using gait parameters derived either from continuous real-world recordings or from unsupervised gait tests. The highest balanced accuracy of 74.0% (sensitivity: 60.0%, specificity: 88.0%) was achieved with a Random Forest Classifier applied to the real-world gait data when aggregating all walking bouts and days of each participant. Our findings suggest that fall risk can be predicted best by merging the entire two-week real-world gait data of a patient, outperforming the prediction using unsupervised gait tests (68.0% balanced accuracy) and contribute to an improved understanding of fall risk prediction.

7 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MZMarkus Zrenner
Markus Zrenner
AKArne Küderle
Arne Küderle
NRNils Roth
Nils Roth
UJUlf Jensen
Ulf Jensen
BDBurkhard Dümler
Burkhard Dümler
Bjoern EskofierBjoern Eskofier
Bjoern Eskofier
Wearable sensor technology already has a great impact on the endurance running community. Smartwatches and heart rate monitors are heavily used to evaluate runners’ performance and monitor their training progress. Additionally, foot-mounted inertial measurement units (IMUs) have drawn the attention of sport scientists due to the possibility to monitor biomechanically relevant spatio-temporal parameters outside the lab in real-world environments. Researchers developed and investigated algorithms to extract various features using IMU data of different sensor positions on the foot. In this work, we evaluate whether the sensor position of IMUs mounted to running shoes has an impact on the accuracy of different spatio-temporal parameters. We compare both the raw data of the IMUs at different sensor positions as well as the accuracy of six endurance running-related parameters. We contribute a study with 29 subjects wearing running shoes equipped with four IMUs on both the left and the right shoes and a motion capture system as ground truth. The results show that the IMUs measure different raw data depending on their position on the foot and that the accuracy of the spatio-temporal parameters depends on the sensor position. We recommend to integrate IMU sensors in a cavity in the sole of a running shoe under the foot’s arch, because the raw data of this sensor position is best suitable for the reconstruction of the foot trajectory during a stride.

11 October 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
MUMartin Ullrich
Martin Ullrich
AMAnnika Mucke
Annika Mucke
AKArne Küderle
Arne Küderle
NRNils Roth
Nils Roth
TGTill Gladow
Till Gladow
Felix KlugeFelix Kluge
Felix Kluge
Gait tests as part of home monitoring study protocols for patients with movement disorders may provide valuable standardized anchor-points for real-world gait analysis using inertial measurement units (IMUs). However, analyzing unsupervised gait tests relies on reliable test annotations by the patients requiring a potentially error-prone interaction with the recording system. To overcome this limitation, this work presents a novel algorithmic pipeline for the automated detection of unsupervised standardized gait tests from continuous real-world IMU data. In a study with twelve Parkinson’s disease patients, we recorded real-world gait data over two weeks using foot-worn IMUs. During continuous daily recordings, the participants performed series of three consecutive ${4}\times {10}$ -Meters-Walking-Tests ( ${4}\times {10}$ MWTs) at different walking speeds, besides their usual daily-living activities. The algorithm first detected these gait test series using a gait sequence detection algorithm, a peak enhancement pipeline, and subsequence Dynamic Time Warping and then decomposed them into single ${4}\times {10}$ MWTs based on the walking speed. In the evaluation with 419 available gait test series, the detection reached an F1-score of 88.9% and the decomposition an F1-score of 94.0%. A concurrent validity evaluation revealed very good agreement between spatio-temporal gait parameters derived from manually labelled and automatically detected ${4}\times {10}$ MWTs. Our algorithm allows to remove the burden of system interaction from the patients and reduces the time for manual data annotation for researchers. The study contributes to an improved automated processing of real-world IMU gait data and enables a simple integration of standardized tests into continuous long-term recordings. This will help to bridge the gap between supervised and unsupervised gait assessment.

9 June 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AKArne Küderle
Arne Küderle
NRNils Roth
Nils Roth
JZJovana Zlatanovic
Jovana Zlatanovic
MZMarkus Zrenner
Markus Zrenner
BEBjoern Eskofier
Bjoern Eskofier
FKFelix Kluge
Felix Kluge
Gait analysis using foot-worn inertial measurement units has proven to be a reliable tool to diagnose and monitor many neurological and musculoskeletal indications. However, only few studies have investigated the robustness of such systems to changes in the sensor attachment and no consensus for suitable sensor positions exists in the research community. Specifically for unsupervised real-world measurements, understanding how the reliability of the monitoring system changes when the sensor is attached differently is from high importance. In these scenarios, placement variations are expected because of user error or personal preferences. In this manuscript, we present the largest study to date comparing different sensor positions and attachments. We recorded 9000 strides with motion-capture reference from 14 healthy participants with six synchronized sensors attached at each foot. Spatial gait parameters were calculated using a double-integration method and compared to the reference system. The results indicate that relevant differences in the accuracy of the stride length exists between the sensor positions. While the average error over multiple strides is comparable, single stride errors and variability parameters differ greatly. We further present a physics model and an analysis of the raw sensor data to understand the origin of the observed differences. This analysis indicates that a variety of attachment parameters can influence the systems’ performance. While this is only the starting point to understand and mitigate these types of errors, we conclude that sensor systems and algorithms must be reevaluated when the sensor position or attachment changes.