Boon Leong Lan

Prof. Boon Leong Lan


Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
WLWei Yin Lim
Wei Yin Lim
BLBoon Leong Lan
Boon Leong Lan
Narayanan RamakrishnanNarayanan Ramakrishnan
Narayanan Ramakrishnan
Coronavirus disease (COVID-19) is a global health crisis caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Real-time reverse transcriptase-polymerase chain reaction (RT-PCR) is the gold standard test for diagnosing COVID-19. Although it is highly accurate, this lab test requires highly-trained personnel and the turn-around time is long. Rapid and inexpensive immuno-diagnostic tests (antigen or antibody test) are available, but these point of care (POC) tests are not as accurate as the RT-PCR test. Biosensors are promising alternatives to these rapid POC tests. Here we review three types of recently developed biosensors for SARS-CoV-2 detection: surface plasmon resonance (SPR)-based, electrochemical and field-effect transistor (FET)-based biosensors. We explain the sensing principles and discuss the advantages and limitations of these sensors. The accuracies of these sensors need to be improved before they could be translated into POC devices for commercial use. We suggest potential biorecognition elements with highly selective target-analyte binding that could be explored to increase the true negative detection rate. To increase the true positive detection rate, we suggest two-dimensional materials and nanomaterials that could be used to modify the sensor surface to increase the sensitivity of the sensor.

27 June 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
BLBoon Leong Lan
Boon Leong Lan
JYJacob Hsiao Wen Yeo
Jacob Hsiao Wen Yeo
Giancardo et al. recently introduced the neuroQWERTY index (nQi), which is a novel motor index derived from computer-key-hold-time data using an ensemble regression algorithm, to detect early-stage Parkinson’s disease. Here, we derive a much simpler motor index from their hold-time data, which is the standard deviation (SD) of the hold-time fluctuations, where fluctuation is defined as the difference between successive natural-log of hold time. Our results show the performance of the SD and nQi tests in discriminating early-stage subjects from controls do not differ, although the SD index is much simpler. There is also no difference in performance between the SD and alternating-finger-tapping tests.

1 May 2020 in Chaos: An Interdisciplinary Journal of Nonlinear Science
Verified
Journal Article
Open access
PDF file
BLBoon Leong Lan
Boon Leong Lan
YLYew Wai Liew
Yew Wai Liew
MTMikito Toda
Mikito Toda
SKSuraya Hani Kamsani
Suraya Hani Kamsani
Complex dynamical systems can shift abruptly from a stable state to an alternative stable state at a tipping point. Before the critical transition, the system either slows down in its recovery rate or flickers between the basins of attraction of the alternative stable states. Whether the heart critically slows down or flickers before it transitions into and out of paroxysmal atrial fibrillation (PAF) is still an open question. To address this issue, we propose a novel definition of cardiac states based on beat-to-beat (RR) interval fluctuations derived from electrocardiogram data. Our results show the cardiac state flickers before PAF onset and termination. Prior to onset, flickering is due to a “tug-of-war” between the sinus node (the natural pacemaker) and atrial ectopic focus/foci (abnormal pacemakers), or the pacing by the latter interspersed among the pacing by the former. It may also be due to an abnormal autonomic modulation of the sinus node. This abnormal modulation may be the sole cause of flickering prior to termination since atrial ectopic beats are absent. Flickering of the cardiac state could potentially be used as part of an early warning or screening system for PAF and guide the development of new methods to prevent or terminate PAF. The method we have developed to define system states and use them to detect flickering can be adapted to study critical transition in other complex systems.

16 October 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
HKHowgen Pratama Kesuma
Howgen Pratama Kesuma
Narayanan RamakrishnanNarayanan Ramakrishnan
Narayanan Ramakrishnan
BLBoon Leong Lan
Boon Leong Lan
ADAmardeep Singh Dhillon
Amardeep Singh Dhillon
AMAjay Achath Mohanan
Ajay Achath Mohanan
It has been recently demonstrated that one-port surface acoustic wave (SAW) resonators known for their high Q value and relatively small device footprint could be utilized for in-liquid mass loading sensing applications where only the reflectors of the device are coated with the sensing film, while the interdigital transducer (IDT) is isolated from the sensing environment. The sensor relies on changes induced in reflectivity and phase velocity of SAW in the region of the reflectors upon detection of the measurand and is particularly advantageous for SAW resonator-type sensors as any contact of the sensing film with the IDT could change its static capacitance during sensing and thereby introduce serious instability in the sensor response. Accordingly, in the present work, the existing scattering matrix approach to the design of one-port SAW resonator filters, which does not cater to the integration of sensing film on the resonator surface, is adapted to develop a method to design one-port SAW resonator sensors utilizing reflectors as sensing element. The reflector block of the one-port SAW resonator is readily split into sensing-active and sensing-inactive parts using the SAW grating transmission matrix in order to study the changes introduced in input admittance of the device for varying level of coverage of the sensing film. The theoretical design approach presented in this work could be used to fabricate high-performance one-port SAW resonator sensors operating at its point of highest sensitivity while utilizing one of the device reflectors as sensing element, without the use of additional impedance matching circuit elements.

11 May 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SLShiuan-Ni Liang
Shiuan-Ni Liang
BLBoon Leong Lan
Boon Leong Lan
The Newtonian and special-relativistic statistical predictions for the mean, standard deviation and probability density function of the position and momentum are compared for the periodically-delta-kicked particle at low speed. Contrary to expectation, we find that the statistical predictions, which are calculated from the same parameters and initial Gaussian ensemble of trajectories, do not always agree if the initial ensemble is sufficiently well-localized in phase space. Moreover, the breakdown of agreement is very fast if the trajectories in the ensemble are chaotic, but very slow if the trajectories in the ensemble are non-chaotic. The breakdown of agreement implies that special-relativistic mechanics must be used, instead of the standard practice of using Newtonian mechanics, to correctly calculate the statistical predictions for the dynamics of a low-speed system.

19 April 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SLShiuan-Ni Liang
Shiuan-Ni Liang
BLBoon Leong Lan
Boon Leong Lan
We show, contrary to expectation, that the trajectory predicted by general-relativistic mechanics for a low-speed weak-gravity system is not always well-approximated by the trajectories predicted by special-relativistic and Newtonian mechanics for the same parameters and initial conditions. If the system is dissipative, the breakdown of agreement occurs for chaotic trajectories only. If the system is non-dissipative, the breakdown of agreement occurs for chaotic trajectories and non-chaotic trajectories. The agreement breaks down slowly for non-chaotic trajectories but rapidly for chaotic trajectories. When the predictions are different, general-relativistic mechanics must therefore be used, instead of special-relativistic mechanics (Newtonian mechanics), to correctly study the dynamics of a weak-gravity system (a low-speed weak-gravity system).