Narayanan Ramakrishnan

Dr. Narayanan Ramakrishnan

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2023 in Microchemical Journal
Verified
Journal Article
Open access
YLYun Mun Lim
Yun Mun Lim
VSVarghese Swamy
Varghese Swamy
Narayanan RamakrishnanNarayanan Ramakrishnan
Narayanan Ramakrishnan
ECEng Seng Chan
Eng Seng Chan
HKHowgen Pratama Kesuma
Howgen Pratama Kesuma

2 November 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
WLWei Yin Lim
Wei Yin Lim
BLBoon Leong Lan
Boon Leong Lan
Narayanan RamakrishnanNarayanan Ramakrishnan
Narayanan Ramakrishnan
Coronavirus disease (COVID-19) is a global health crisis caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Real-time reverse transcriptase-polymerase chain reaction (RT-PCR) is the gold standard test for diagnosing COVID-19. Although it is highly accurate, this lab test requires highly-trained personnel and the turn-around time is long. Rapid and inexpensive immuno-diagnostic tests (antigen or antibody test) are available, but these point of care (POC) tests are not as accurate as the RT-PCR test. Biosensors are promising alternatives to these rapid POC tests. Here we review three types of recently developed biosensors for SARS-CoV-2 detection: surface plasmon resonance (SPR)-based, electrochemical and field-effect transistor (FET)-based biosensors. We explain the sensing principles and discuss the advantages and limitations of these sensors. The accuracies of these sensors need to be improved before they could be translated into POC devices for commercial use. We suggest potential biorecognition elements with highly selective target-analyte binding that could be explored to increase the true negative detection rate. To increase the true positive detection rate, we suggest two-dimensional materials and nanomaterials that could be used to modify the sensor surface to increase the sensitivity of the sensor.

30 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
WLWei Yin Lim
Wei Yin Lim
CGChoon-Hian Goh
Choon-Hian Goh
KYKeenan Zhihong Yap
Keenan Zhihong Yap
Narayanan RamakrishnanNarayanan Ramakrishnan
Narayanan Ramakrishnan
Irregularities in breathing patterns can be detected using breath monitor sensors, and this help clinicians to predict health disorders ranging from sleep disorders to heart failures. Variations in humidity during the inhalation and exhalation of breath have been utilized as a marker to detect breath patterns, and graphene-based devices are the favored sensing media for relative humidity (RH). In general, most graphene-based RH sensors have been used to explore resistance change as a measurement parameter to calibrate against the RH value, and they are prone to noise interference. Here, we fabricated RH sensors using graphene ink as a sensing medium and printed them in the shape of interdigital electrodes on glossy paper using an office inkjet printer. Further, we investigated the capacitance change in the sensor for the RH changes in the range of 10–70%. It exhibited excellent sensitivity with 0.03 pF/% RH, good stability, and high intraday and interday repeatability, with relative standard deviations of 1.2% and 2.2%, respectively. Finally, the sensor was embedded into a face mask and interfaced with a microcontroller, and capacitance change was measured under three different breathing situations: normal breathing, deep breathing, and coughing. The result show that the dominant frequency for normal breath is 0.22 Hz, for deep breath, it is 0.11 Hz, and there was no significant dominant cough frequency due to persistent coughing and inconsistent patterns. Moreover, the sensor exhibited a short response and recovery time (<5 s) during inhalation and exhalation. Thus, the proposed paper-based RH sensor is promising wearable and disposable healthcare technology for clinical and home care health applications.

16 April 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CKChi Kam Kent
Chi Kam Kent
Narayanan RamakrishnanNarayanan Ramakrishnan
Narayanan Ramakrishnan
HKHowgen Pratama Kesuma
Howgen Pratama Kesuma
Surface Acoustic Wave (SAW) devices have long been recognized as proficient sensors, capable of detecting an array of chemical and physical parameters. These range from the identification of gas type and concentration, the intensity of ultraviolet light, fluctuations in temperature, and changes in relative humidity. Historically, delay line model SAW devices have been the preferred choice for these sensor applications due to their proven reliability and broad versatility. However, recent advancements have paved the way for the development of one-port SAW resonators, which offer several compelling benefits. These devices are characterized by their relatively compact size and superior sensitivity compared to their delay line counterparts. Such attributes make them appealing for implementation in a variety of sensing applications. However, the transition to these novel devices has not been without challenges. One significant hurdle has been maintaining the original performance of these devices following their integration with a sensing film. In addition, the device is typically not suitable in high temperature condition which limits the implementation for environmental sensor. Researchers have been trying to address these issues and leveraging the inherent advantages of these devices. This comprehensive review serves to provide an in-depth analysis of the state of one-port SAW resonators. The paper delves into current trends and offers detailed insights into their design and fabrication methodologies. Additionally, it explores their implementation as sensors, discussing both the successes and ongoing challenges associated with their use. The paper also highlights the potential opportunities and advancements that one-port SAW resonators could bring to the field of sensor technology.

6 February 2013 in Sensors
Verified
Journal Article
Open access
PDF file
AMAjay Achath Mohanan
Ajay Achath Mohanan
SIShabiul Islam
Shabiul Islam
SASawal Hamid Md Ali
Sawal Hamid Md Ali
RPRajendran Parthiban
Rajendran Parthiban
Narayanan RamakrishnanNarayanan Ramakrishnan
Narayanan Ramakrishnan
In this work mass loading sensitivity of a Sezawa wave mode based surface acoustic wave (SAW) device is investigated through finite element method (FEM) simulation and the prospects of these devices to function as highly sensitive SAW sensors is reported. A ZnO/Si layered SAW resonator is considered for the simulation study. Initially the occurrence of Sezawa wave mode and displacement amplitude of the Rayleigh and Sezawa wave mode is studied for lower ZnO film thickness. Further, a thin film made of an arbitrary material is coated over the ZnO surface and the resonance frequency shift caused by mass loading of the film is estimated. It was observed that Sezawa wave mode shows significant sensitivity to change in mass loading and has higher sensitivity (eight times higher) than Rayleigh wave mode for the same device configuration. Further, the mass loading sensitivity was observed to be greater for a low ZnO film thickness to wavelength ratio. Accordingly, highly sensitive SAW sensors can be developed by coating a sensing medium over a layered SAW device and operating at Sezawa mode resonance frequency. The sensitivity can be increased by tuning the ZnO film thickness to wavelength ratio.

23 March 2012 in Sensors
Verified
Journal Article
Open access
PDF file
Narayanan RamakrishnanNarayanan Ramakrishnan
Narayanan Ramakrishnan
HNHarshal B. Nemade
Harshal B. Nemade
RPRoy Paily
Roy Paily
Recently we reported experimental and simulation results on an increase in resonance frequency of a SAW resonator caused by mass loading of micropillars made of SU-8, attached normal to the surface of the resonator. We concluded that SAW resonator and the SU-8 micropillars in unison form a system of coupled resonators. We have now extended this work and performed a finite element method simulation to study the resonance frequency characteristics of the SAW-based coupled resonator. In this paper we report the effect of the resonance frequency of the micropillars on the resonance frequency of the system of coupled resonators, and observe the coupling of micropillar resonance and the propagating SAW as described in the well known Dybwad system of coupled resonators.