Roeland De Meulenaere

Mr. Roeland De Meulenaere

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2022 in Applied Energy
Verified
Journal Article
Open access
JGJ. Garcet
J. Garcet
RMRoeland De Meulenaere
Roeland De Meulenaere
JBJulien Blondeau
Julien Blondeau

18 January 2025 in Journal of Energy Storage
Verified
Journal Article
Closed access
GWGuangxuan Wang
Guangxuan Wang
KVKevin Verleysen
Kevin Verleysen
RMRoeland De Meulenaere
Roeland De Meulenaere
JBJulien Blondeau
Julien Blondeau

27 September 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RMRoeland De Meulenaere
Roeland De Meulenaere
DCDiederik Coppitters
Diederik Coppitters
ASAle Sikkema
Ale Sikkema
TMTim Maertens
Tim Maertens
JBJulien Blondeau
Julien Blondeau
The assessment of the future thermodynamics performance of a retrofitted heat and power production unit is prone to many uncertainties due to the large number of parameters involved in the modeling of all its components. To carry out uncertainty quantification analysis, alternatives to the traditional Monte Carlo method must be used due to the large stochastic dimension of the problem. In this paper, sparse polynomial chaos expansion (SPCE) is applied to the retrofit of a large coal-fired power plant into a biomass-fired combined heat and power unit to quantify the main drivers and the overall uncertainty on the plant’s performance. The thermodynamic model encompasses over 180 components and 1500 parameters. A methodology combining the use of SPCE and expert judgment is proposed to narrow down the sources of uncertainty and deliver reliable probability distributions for the main key performance indicators (KPIs). The impact of the uncertainties on each input parameter vary with the considered KPI and its assessment through the computation of Sobol’ indices. For both coal and biomass operations, the most impactful input parameters are the composition of the fuel and its heating value. The uncertainty on the performance and steam quality parameters is not much affected by the retrofit. Key furnace parameters exhibit a skewed probability distribution with large uncertainties, which is a strong attention point in terms of boiler operation and maintenance.

30 August 2024 in Results in Engineering
Verified
Journal Article
Open access
RMRoeland De Meulenaere
Roeland De Meulenaere
KVKevin Verleysen
Kevin Verleysen
APAlessio Pappa
Alessio Pappa
KBKévin Bioche
Kévin Bioche
WPWard De Paepe
Ward De Paepe
JBJulien Blondeau
Julien Blondeau

8 December 2022 in Thermal Science and Engineering Progress
Verified
Journal Article
Closed access
RMRoeland De Meulenaere
Roeland De Meulenaere
DCDiederik Coppitters
Diederik Coppitters
TMTim Maertens
Tim Maertens
FCFrancesco Contino
Francesco Contino
JBJulien Blondeau
Julien Blondeau

18 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
RMRoeland De Meulenaere
Roeland De Meulenaere
TMTim Maertens
Tim Maertens
ASAle Sikkema
Ale Sikkema
RBRune Brusletto
Rune Brusletto
TBTanja Barth
Tanja Barth
JBJulien Blondeau
Julien Blondeau
This paper aims at assessing the impact of retrofitting an existing, 730 MWe, coal-fired power plant into a biomass-fired combined heat and power (CHP) plant on its energetic and exergetic performances. A comprehensive thermodynamic model of the power plant was developed and validated against field data, resulting in less than 1% deviation between the model and the measurements for the main process parameters. The validated model was then used to predict the behaviour of the biomass CHP after retrofitting. The modelled CHP unit is coupled to a steam-explosion biomass upgrading plant, a biorefinery process, and a high-temperature heat network. 13 scenarios were studied. At constant boiler load, delivering heat to the considered heat clients can increase the total energy efficiency of the plant from 44% (electricity only) to 64%, while the total exergy efficiency decreases from 39% to 35%. A total energy efficiency of 67% could be reached by lowering the network temperature from 120∘C to 70∘C. Identifying the needed heat clients could, however, represent a limiting factor to reach such high efficiencies. For a constant power demand, increasing the boiler load from 80 to 100% in order to provide additional heat makes the total energy efficiency increase from 43% to 55%, while the total exergy efficiency decreases from 39% to 36%.