Hossein Bassir

Dr. Hossein Bassir


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 November 2018 in Journal of Periodontology
Verified
Journal Article
Closed access
PDF file
HBHossein Bassir
Hossein Bassir
KKKarim El Kholy
Karim El Kholy
CCChia‐Yu Chen
Chia‐Yu Chen
KLKyu Ha Lee
Kyu Ha Lee
GIGiuseppe Intini
Giuseppe Intini

3 October 2018 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
JRJustin Ranaan
Justin Ranaan
HBHossein Bassir
Hossein Bassir
LALuciano Andrada
Luciano Andrada
ASAhmad Reza Shamshiri
Ahmad Reza Shamshiri
MMMohamed Maksoud
Mohamed Maksoud
KGKevin Guze
Kevin Guze

12 November 2021 in Materials
Verified
Journal Article
Open access
PDF file
Mahnaz ArshadMahnaz Arshad
Mahnaz Arshad
SZSina Khayat Zadeh
Sina Khayat Zadeh
MAMohammad Atai
Mohammad Atai
GSGholamreza Shirani
Gholamreza Shirani
Georgios RomanosGeorgios Romanos
Georgios Romanos
HBHossein Bassir
Hossein Bassir
The aim of this study was to assess the effect of application of a recently developed bio-adhesive (Impladhesive) to abutment screw threads on the removal torque value and rotational misfit at the implant–abutment junction. This in vitro study evaluated 20 implant fixtures and 20 straight abutments. Specimens were randomly divided into two groups (n = 10) with/without adhesive application. In the adhesive group, the abutment was dipped in Impladhesive before torquing. In the control group, the abutment was torqued conventionally without adhesive application. The removal torque value was recorded after completion of the cyclic loading of 500,000 cycles with 2 Hz frequency and 75 N load. Rotational misfit was recorded using a video measuring machine. After applying the torque, the change in the bisector angle on the abutment hex was recorded for each implant. The biocompatibility of Impladhesive was evaluated using a MTT cell vitality assay. Normal distribution of data was assessed using the Kolmogorov–Smirnov test. Data were analyzed using a t-test and Pearson’s correlation coefficient The application of Impladhesive at the implant–abutment interface resulted in significantly greater mean removal torque value compared to the control group (p = 0.008). In addition, the mean rotational misfit at the implant–abutment interface was significantly lower in the use of Impladhesive compared to the control group (p = 0.001). In addition, the cell vitality was found to be greater than 80% at all evaluated time points. It can be concluded that the application of Impladhesive on the abutment screw significantly decreased rotational misfit and increased the removal torque value. Future studies are needed to evaluate the efficacy of this bio-adhesive an in vivo setting.