Heejoon Park

Dr. Heejoon Park

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2010 in Healthcare Informatics Research
Verified
Journal Article
Open access
PDF file
ASA Mi Shin
A Mi Shin
ILIn Hee Lee
In Hee Lee
GLGyeong Ho Lee
Gyeong Ho Lee
HPHeejoon Park
Heejoon Park
HPHyung Seop Park
Hyung Seop Park
YKYoon Nyun Kim
Yoon Nyun Kim
Shin AM, et al. Healthc Inform Res. 2010 Jun;16(2):77-81. http://dx.doi.org/10.4258/hir.2010.16.2.77

27 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
HPHeejoon Park
Heejoon Park
Qun WeiQun Wei
Qun Wei
Soomin LeeSoomin Lee
Soomin Lee
MLMiran Lee
Miran Lee
Heart sounds and heart rate (pulse) are the most common physiological signals used in the diagnosis of cardiovascular diseases. Measuring these signals using a device and analyzing their interrelationships simultaneously can improve the accuracy of existing methods and propose new approaches for the diagnosis of cardiovascular diseases. In this study, we have presented a novel smart stethoscope based on multimodal physiological signal measurement technology for personal cardiovascular health monitoring. The proposed device is designed in the shape of a compact personal computer mouse for easy grasping and attachment to the surface of the chest using only one hand. A digital microphone and photoplehysmogram sensor are installed on the bottom and top surfaces of the device, respectively, to measure heart sound and pulse from the user’s chest and finger simultaneously. In addition, a high-performance Bluetooth Low Energy System-on-Chip ARM microprocessor is used for pre-processing of measured data and communication with the smartphone. The prototype is assembled on a manufactured printed circuit board and 3D-printed shell to conduct an in vivo experiment to test the performance of physiological signal measurement and usability by observing users’ muscle fatigue variation.

20 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Soomin LeeSoomin Lee
Soomin Lee
Qun WeiQun Wei
Qun Wei
HPHeejoon Park
Heejoon Park
YNYuri Na
Yuri Na
DJDonghwa Jeong
Donghwa Jeong
HLHongjoon Lim
Hongjoon Lim
Cardiac auscultation is one of the most popular diagnosis approaches to determine cardiovascular status based on listening to heart sounds with a stethoscope. However, heart sounds can be masked by visceral sounds such as organ movement and breathing, and a doctor’s level of experience can more seriously affect the accuracy of auscultation results. To improve the accuracy of auscultation, and to allow nonmedical staff to conduct cardiac auscultation anywhere and anytime, a hybrid-type personal smart stethoscope with an automatic heart sound analysis function is presented in this paper. The device was designed with a folding finger-ring shape that can be worn on the finger and placed on the chest to measure photoplethysmogram (PPG) signals and acquire the heart sound simultaneously. The measured heart sounds are detected as phonocardiogram (PCG) signals, and the boundaries of the heart sound variation and the peaks of the PPG signal are detected in preprocessing by an advanced Shannon entropy envelope. According to the relationship between PCG and PPG signals, an automatic heart sound analysis algorithm based on calculating the time interval between the first and second heart sounds (S1, S2) and the peak of the PPG was developed and implemented via the manufactured prototype device. The prototype device underwent accuracy and usability testing with 20 young adults, and the experimental results showed that the proposed smart stethoscope could satisfactorily collect the heart sounds and PPG signals. In addition, within the developed algorithm, the device was as accurate in start-points of heart sound detection as professional physiological signal-acquisition systems. Furthermore, the experimental results demonstrated that the device was able to identify S1 and S2 heart sounds automatically with high accuracy.

16 March 2015 in Sensors
Verified
Journal Article
Open access
PDF file
Jong-Ha LeeJong-Ha Lee
Jong-Ha Lee
YKYoon Nyun Kim
Yoon Nyun Kim
HPHeejoon Park
Heejoon Park
The tissue inclusion parameter estimation method is proposed to measure the stiffness as well as geometric parameters. The estimation is performed based on the tactile data obtained at the surface of the tissue using an optical tactile sensation imaging system (TSIS). A forward algorithm is designed to comprehensively predict the tactile data based on the mechanical properties of tissue inclusion using finite element modeling (FEM). This forward information is used to develop an inversion algorithm that will be used to extract the size, depth, and Young's modulus of a tissue inclusion from the tactile data. We utilize the artificial neural network (ANN) for the inversion algorithm. The proposed estimation method was validated by a realistic tissue phantom with stiff inclusions. The experimental results showed that the proposed estimation method can measure the size, depth, and Young's modulus of a tissue inclusion with 0.58%, 3.82%, and 2.51% relative errors, respectively. The obtained results prove that the proposed method has potential to become a useful screening and diagnostic method for breast cancer.

1 January 2019 in Technology and Health Care
Verified
Journal Article
Open access
PDF file
QWQun Wei
Qun Wei
JLJyung Hyun Lee
Jyung Hyun Lee
HPHeejoon Park
Heejoon Park
BACKGROUND: Children struggle to fall asleep by themselves because of their physiological characteristics. Therefore, research has been carried on various devices (such as a smartphone) to assist in improving the sleep quality of children. However, all such devices need to be controlled by parents and do not have functions for monitoring the sleep environment. OBJECTIVE: In this paper, a smart sleep-lighting system that includes a sleep-lighting device and a smartphone dongle is developed to improve the sleep environment of children. METHODS: The temperature, humidity, and luminance of the sleep environment are monitored and analyzed by the sleep-lighting device to control multi-color light and audio components. The colored light emitted by the multi-color light can be adjusted to improve the sleep atmosphere. Also, the audio component can play white noise to induce sleep. In addition, parents can use a smartphone dongle with a multi-channel wireless communication method to monitor and control one or more lighting devices in different locations in real time. RESULTS: For environmental monitoring, average difference between proposed device and commercial sensor from chamber setting temperature 15[ ]C to 35[ ]C was 0.588[ ]C [ ] 0.10[ ]C, and average error value of the humidity measurement was 0.74% at 40% [ ] 60% RH. Also, the manufactured sleep-lighting device shows good performance in multi-color light emission, and playing of white noise. As result, the smartphone connected to the proposed smartphone dongle enables monitoring and control of the proposed lighting device in a wireless well. CONCLUSIONS: The manufactured sleep-lighting device has a high-precision temperature and humidity sensor and a luminance sensor that can accurately monitor the sleeping environment. The lighting device can play white noise to induce sleep in children. Also, a multi-color LED light is operated via a smartphone application to improve the sleep atmosphere. The measured data will be sent to the lighting device and processed together with sleep environment data in order to improve the sleep quality. Additionally, the final system will be tested for real end-users with clinical experiments by sleep research center of a university hospital.

Verified
Journal Article
Open access
PDF file
TNTahsin Nairuz
Tahsin Nairuz
JHJin-Chul Heo
Jin-Chul Heo
HPHeejoon Park
Heejoon Park
Jong-Ha LeeJong-Ha Lee
Jong-Ha Lee
Alzheimer’s disease (AD) is a progressive neurodegenerative disorder characterized by amyloid-β (Aβ) accumulation, synaptic dysfunction, and cognitive decline. Current pharmacological treatments provide only symptomatic relief without altering disease progression. Photobiomodulation therapy (PBMT), a light-based intervention, has shown neuroprotective potential, although its exact neurobiological mechanisms in AD pathogenesis remain obscure. In this study, we investigated the effects of PBMT using a 660 nm wavelength light-emitting diode (LED) in 5xFAD transgenic mouse, a well-established model of early-onset AD. Mice were subjected to once daily PBMT sessions over a defined treatment period and outcomes were assessed through immunohistochemical analysis of hippocampal regions (CA1, CA2, CA3, and dentate gyrus) alongside behavioral testing using the Y-maze spontaneous alternation task. PBMT significantly reduced Aβ plaque load across hippocampal regions, accompanied by improved preservation of neuronal morphology. Furthermore, PBMT significantly upregulated SIRT1 expression, a critical regulator of synaptic plasticity and memory processes. Behaviorally, PBMT-treated mice displayed enhanced spatial working memory compared with controls, indicating a functional benefit linked to the observed molecular and structural changes. These findings suggest that 660 nm PBMT attenuates hallmark AD pathology, promotes neuroprotective pathways, and improves cognition, highlighting its potential as a disease-modifying therapy that warrants further preclinical and clinical investigation.