Qun Wei

Prof. Qun Wei

Keimyung University, Daegu, Republic of Korea

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ARAbdur Rauf
Abdur Rauf
MAMuhammad Adil
Muhammad Adil
SMShabeer Ahmad Mian
Shabeer Ahmad Mian
GRGul Rahman
Gul Rahman
EAEjaz Ahmed
Ejaz Ahmed
Qun WeiQun Wei
Qun Wei
Hematite (Fe2O3) is one of the best candidates for photoelectrochemical water splitting due to its abundance and suitable bandgap. However, its efficiency is mostly impeded due to the intrinsically low conductivity and poor light absorption. In this study, we targeted this intrinsic behavior to investigate the thermodynamic stability, photoconductivity and optical properties of rhodium doped hematite using density functional theory. The calculated formation energy of pristine and rhodium doped hematite was − 4.47 eV and − 5.34 eV respectively, suggesting that the doped material is thermodynamically more stable. The DFT results established that the bandgap of doped hematite narrowed down to the lower edge (1.61 eV) in the visible region which enhanced the optical absorption and photoconductivity of the material. Moreover, doped hematite has the ability to absorb a broad spectrum (250–800) nm. The enhanced optical absorption boosted the photocurrent and incident photon to current efficiency. The calculated results also showed that the incorporation of rhodium in hematite induced a redshift in optical properties.

17 February 2019 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
Qun WeiQun Wei
Qun Wei
HPHee-Joon Park
Hee-Joon Park
JLJyunghyun Lee
Jyunghyun Lee
In this paper, a user-friendly and low-cost wireless health monitoring system that measures skin temperature from the back of the body for monitoring the core body temperature is proposed. To measure skin temperature accurately, a semiconductor-based microtemperature sensor with a maximum accuracy of ±0.3°C was chosen and controlled by a high-performance/low-power consumption Acorn-Reduced Instruction Set Computing Machine (ARM) architecture microcontroller to build the temperature measuring device. Relying on a 2.4 GHz multichannel Gaussian frequency shift keying (GFSK) RF communication technology, up to 100 proposed temperature measuring devices can transmit the data to one receiver at the same time. The shell of the proposed wireless temperature-measuring device was manufactured via a 3D printer, and the device was assembled to conduct the performance tests and in vivo experiments. The performance test was conducted with a K-type temperature sensor in a temperature chamber to observe temperature measurement performance. The results showed an error value between two devices was less than 0.1°C from 25 to 40°C. For the in vivo experiments, the device was attached on the back of 10 younger male subjects to measure skin temperature to investigate the relationship with ear temperature. According to the experimental results, an algorithm based on the curve-fitting method was implemented in the proposed device to estimate the core body temperature by the measured skin temperature value. The algorithm was established as a linear model and set as a quadratic formula with an interpolant and with each coefficient for the equation set with 95% confidence bounds. For evaluating the goodness of fit, the sum of squares due to error (SSE), R-square, adjusted R-square, and root mean square error (RMSE) values were 33.0874, 0.0212, 0.0117, and 0.3998, respectively. As the experimental results have shown, the mean value for an error between ear temperature and estimated core body temperature is about ±0.19°C, and the mean bias is 0.05 ± 0.14°C when the subjects are in steady status.

27 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
HPHeejoon Park
Heejoon Park
Qun WeiQun Wei
Qun Wei
Soomin LeeSoomin Lee
Soomin Lee
MLMiran Lee
Miran Lee
Heart sounds and heart rate (pulse) are the most common physiological signals used in the diagnosis of cardiovascular diseases. Measuring these signals using a device and analyzing their interrelationships simultaneously can improve the accuracy of existing methods and propose new approaches for the diagnosis of cardiovascular diseases. In this study, we have presented a novel smart stethoscope based on multimodal physiological signal measurement technology for personal cardiovascular health monitoring. The proposed device is designed in the shape of a compact personal computer mouse for easy grasping and attachment to the surface of the chest using only one hand. A digital microphone and photoplehysmogram sensor are installed on the bottom and top surfaces of the device, respectively, to measure heart sound and pulse from the user’s chest and finger simultaneously. In addition, a high-performance Bluetooth Low Energy System-on-Chip ARM microprocessor is used for pre-processing of measured data and communication with the smartphone. The prototype is assembled on a manufactured printed circuit board and 3D-printed shell to conduct an in vivo experiment to test the performance of physiological signal measurement and usability by observing users’ muscle fatigue variation.

1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
KYKiwook Yang
Kiwook Yang
Hyunsu LeeHyunsu Lee
Hyunsu Lee
ICIn-Jang Choi
In-Jang Choi
WJWoonhyeok Jeong
Woonhyeok Jeong
HKHongtae Kim
Hongtae Kim
JLJae-Ho Lee
Jae-Ho Lee
Knowledge of anatomical variations of the limb’s main arteries is significant for the clinicians. Thus, this study is aimed at examining the branching pattern and anatomical variations of the axillary artery. We conducted research on 59 upper limbs of adult human donated cadavers. All axillary artery branches’ origins were assessed, and the correlations between points of origins and variations of specific branches were evaluated. The average length of the axillary artery was found to be 11.22 cm, and this length was defined as reference line. Based on this reference line, the first, second, and third parts were 37.56%, 39%, and 30.05%, respectively. The STA was originated from 25.11%. The TAA and LTA were 42.67% and 54.82%, respectively. The SSA, ACHA, and PCHA were 64.72%, 83.89%, and 84.53%, respectively. The origin of LTA was correlated with that of SSA (R = 0.473, P < 0.05) and AHCA (R = 0.307, P < 0.05), respectively. And there was a positive correlation between AHCA and PHCA (R = 0.705, P < 0.05). The number of branches ranged from 3~6, and 9 types were shown. The most frequent branching pattern was common origin of the LTA and SSA (22/59). And AHCA and PHCA were originated together in 19 cases, and both patterns were combined in 12 cases. TTA and LTA branched together in 9 cases, and common trunk for the SSA, PHCA, and AHCA was found in 2 cases. According to this pattern, the origin of LTA and PCHA was significantly different. This information is particularly useful for surgeons and clinicians.

20 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Soomin LeeSoomin Lee
Soomin Lee
Qun WeiQun Wei
Qun Wei
HPHeejoon Park
Heejoon Park
YNYuri Na
Yuri Na
DJDonghwa Jeong
Donghwa Jeong
HLHongjoon Lim
Hongjoon Lim
Cardiac auscultation is one of the most popular diagnosis approaches to determine cardiovascular status based on listening to heart sounds with a stethoscope. However, heart sounds can be masked by visceral sounds such as organ movement and breathing, and a doctor’s level of experience can more seriously affect the accuracy of auscultation results. To improve the accuracy of auscultation, and to allow nonmedical staff to conduct cardiac auscultation anywhere and anytime, a hybrid-type personal smart stethoscope with an automatic heart sound analysis function is presented in this paper. The device was designed with a folding finger-ring shape that can be worn on the finger and placed on the chest to measure photoplethysmogram (PPG) signals and acquire the heart sound simultaneously. The measured heart sounds are detected as phonocardiogram (PCG) signals, and the boundaries of the heart sound variation and the peaks of the PPG signal are detected in preprocessing by an advanced Shannon entropy envelope. According to the relationship between PCG and PPG signals, an automatic heart sound analysis algorithm based on calculating the time interval between the first and second heart sounds (S1, S2) and the peak of the PPG was developed and implemented via the manufactured prototype device. The prototype device underwent accuracy and usability testing with 20 young adults, and the experimental results showed that the proposed smart stethoscope could satisfactorily collect the heart sounds and PPG signals. In addition, within the developed algorithm, the device was as accurate in start-points of heart sound detection as professional physiological signal-acquisition systems. Furthermore, the experimental results demonstrated that the device was able to identify S1 and S2 heart sounds automatically with high accuracy.

1 January 2020 in Technology and Health Care
Verified
Journal Article
Open access
PDF file
YKYoung-Kyu Kim
Young-Kyu Kim
YJYoung-Jong Jang
Young-Jong Jang
DKDoung-Sun Kim
Doung-Sun Kim
Qun WeiQun Wei
Qun Wei
BACKGROUND: Biomedical engineers in particular require fast and powerful data processing systems to process computerized tomography and magnetic resonance imaging scans and other medical imaging technologies. However, current computer data processing technologies are unable to satisfy such requirements. A promising approach to addressing these limitations is processing in memory (PIM). Unfortunately, several issues, such as the compatibility and interconnection of PIM with legacy systems, still remain. OBJECTIVE: This paper proposes a standard memory bus-based PIM interface for medical image processing and a PIM platform. The proposed PIM interface can overcome problems of compatibility with legacy systems. METHODS: We will adapt an embedded system based on a commercial application processor (AP) to a medical image system to verify the functions and the performance of the proposed PIM interface. Using the PIM platform, we apply the proposed PIM interface and the AP to execute an image processing program, measure the image processing times, and compare the results of the measurements. RESULTS: Experimental results show that while the functions of the proposed PIM interface are normal, the processing time of PIM is more than 81% faster than that of the AP. CONCLUSION: The experimental results prove that the proposed PIM interface is able to solve problems of compatibility with legacy systems. We foresee that not only the medical image processing field but also a number of academic fields and professional sectors will use PIM in their data-intensive applications.