Avinash Kumar Singh

Dr. Avinash Kumar Singh

School of Computer Science, University of Technology Sydney, Sydney, Australia

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2017 in IEEE Access
Verified
Journal Article
Open access
CLChin-Teng Lin
Chin-Teng Lin
Chun-Hsiang (Michael) ChuangChun-Hsiang (Michael) Chuang
Chun-Hsiang (Michael) Chuang
ZCZehong Cao
Zehong Cao
Avinash Kumar SinghAvinash Kumar Singh
Avinash Kumar Singh
CHChih-Sheng Hung
Chih-Sheng Hung
SWShuu-Jiun Wang
Shuu-Jiun Wang
There are current limitations in the recording technologies for measuring EEG activity in clinical and experimental applications. Acquisition systems involving wet electrodes are time-consuming and uncomfortable for the user. Furthermore, dehydration of the gel affects the quality of the acquired data and reliability of long-term monitoring. As a result, dry electrodes may be used to facilitate the transition from neuroscience research or clinical practice to real-life applications. EEG signals can be easily obtained using dry electrodes on the forehead, which provides extensive information concerning various cognitive dysfunctions and disorders. This paper presents the usefulness of the forehead EEG with advanced sensing technology and signal processing algorithms to support people with healthcare needs, such as monitoring sleep, predicting headaches, and treating depression. The proposed system for evaluating sleep quality is capable of identifying five sleep stages to track nightly sleep patterns. Additionally, people with episodic migraines can be notified of an imminent migraine headache hours in advance through monitoring forehead EEG dynamics. The depression treatment screening system can predict the efficacy of rapid antidepressant agents. It is evident that frontal EEG activity is critically involved in sleep management, headache prevention, and depression treatment. The use of dry electrodes on the forehead allows for easy and rapid monitoring on an everyday basis. The advances in EEG recording and analysis ensure a promising future in support of personal healthcare solutions.

2 May 2019
Verified
Conference Paper
Open access
LGLukas Gehrke
Lukas Gehrke
SASezen Akman
Sezen Akman
PLPedro Lopes
Pedro Lopes
ACAlbert Chen
Albert Chen
Avinash Kumar SinghAvinash Kumar Singh
Avinash Kumar Singh
KGKlaus Gramann
Klaus Gramann

7 May 2018 in IEEE Access
Verified
Journal Article
Open access
Avinash Kumar SinghAvinash Kumar Singh
Avinash Kumar Singh
HCHsiang-Ting Chen
Hsiang-Ting Chen
YCYu-Feng Cheng
Yu-Feng Cheng
JKJung-Tai King
Jung-Tai King
LKLi-Wei Ko
Li-Wei Ko
CLChin-Teng Lin
Chin-Teng Lin
Different rendering styles induce different levels of agency and user behaviors in virtual reality (VR) environments. We applied an electroencephalogram (EEG)-based approach to investigate how the rendering style of the users’ hands affects behavioral and cognitive responses. To this end, we introduced prediction errors due to cognitive conflicts during a 3D object selection task by manipulating the selection distance of the target object. The results showed that, for participants with high behavioral inhibition scores (BIS), the amplitude of the negative event-related potential at approximately 50-250 ms correlated with the realism of the virtual hands. Concurring with the uncanny valley theory, these findings suggest that the more realistic the representation of the user’s hand is, the more sensitive the user becomes towards subtle errors, such as tracking inaccuracies.

15 January 2018 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
CLChin-Teng Lin
Chin-Teng Lin
CHChih-Sheng Huang
Chih-Sheng Huang
WYWen-Yu Yang
Wen-Yu Yang
Avinash Kumar SinghAvinash Kumar Singh
Avinash Kumar Singh
CCChun-Hsiang Chuang
Chun-Hsiang Chuang
YWYu-Kai Wang
Yu-Kai Wang
Electroencephalogram (EEG) signals are usually contaminated with various artifacts, such as signal associated with muscle activity, eye movement, and body motion, which have a noncerebral origin. The amplitude of such artifacts is larger than that of the electrical activity of the brain, so they mask the cortical signals of interest, resulting in biased analysis and interpretation. Several blind source separation methods have been developed to remove artifacts from the EEG recordings. However, the iterative process for measuring separation within multichannel recordings is computationally intractable. Moreover, manually excluding the artifact components requires a time-consuming offline process. This work proposes a real-time artifact removal algorithm that is based on canonical correlation analysis (CCA), feature extraction, and the Gaussian mixture model (GMM) to improve the quality of EEG signals. The CCA was used to decompose EEG signals into components followed by feature extraction to extract representative features and GMM to cluster these features into groups to recognize and remove artifacts. The feasibility of the proposed algorithm was demonstrated by effectively removing artifacts caused by blinks, head/body movement, and chewing from EEG recordings while preserving the temporal and spectral characteristics of the signals that are important to cognitive research.

28 March 2018 in IEEE Transactions on Cognitive and Developmental Systems
Verified
Journal Article
Closed access
CLChin-Teng Lin
Chin-Teng Lin
CCChing-Yu Chiu
Ching-Yu Chiu
Avinash Kumar SinghAvinash Kumar Singh
Avinash Kumar Singh
JKJung-Tai King
Jung-Tai King
LKLi-Wei Ko
Li-Wei Ko
YWYu-Kai Wang
Yu-Kai Wang
Several kinds of brain-computer interface (BCI) systems have been proposed to compensate for the lack of medical technology for assisting patients who lose the ability to use motor functions to communicate with the outside world. However, most of the proposed systems are limited by their non-portability, impracticality and inconvenience because of the adoption of wired or invasive electroencephalography (EEG) acquisition devices. Another common limitation is the shortage of functions provided because of the difficulty of integrating multiple functions into one BCI system. In this study, we propose a wireless, non-invasive and multifunctional assistive system which integrates steady state visually evoked potential (SSVEP)-based BCI and a robotic arm to assist patients to feed themselves. Patients are able to control the robotic arm via the BCI to serve themselves food. Three other functions: video entertainment, video calling, and active interaction are also integrated. This is achieved by designing a functional menu and integrating multiple subsystems. A refinement decision-making mechanism is incorporated to ensure the accuracy and applicability of the system. Fifteen participants were recruited to validate the usability and performance of the system. The averaged accuracy and information transfer rate (ITR) achieved is 90.91% and 24.94 bit per min respectively. The feedback from the participants demonstrates that this assistive system is able to significantly improve the quality of daily life.

5 May 2021 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
AAAshlesha Akella
Ashlesha Akella
Avinash Kumar SinghAvinash Kumar Singh
Avinash Kumar Singh
DLDaniel Leong
Daniel Leong
SLSara Lal
Sara Lal
PNPhillip Newton
Phillip Newton
CLChin-Teng Lin
Chin-Teng Lin
Objective: Mental stress is a major problem in our society and has become an area of interest for many psychiatric researchers. One primary research focus area is the identification of bio-markers that not only identify stress but also predict the conditions (or tasks) that cause stress. Electroencephalograms (EEGs) have been used for a long time to study and identify bio-markers. While these bio-markers have successfully predicted stress in EEG studies for binary conditions, their performance is suboptimal for multiple conditions of stress. Methods: To overcome this challenge, we propose using latent based representations of the bio-markers, which have been shown to significantly improve EEG performance compared to traditional bio-markers alone. We evaluated three commonly used EEG based bio-markers for stress, the brain load index (BLI), the spectral power values of EEG frequency bands (alpha, beta and theta), and the relative gamma (RG), with their respective latent representations using four commonly used classifiers. Results: The results show that spectral power value based bio-markers had a high performance with an accuracy of 83%, while the respective latent representations had an accuracy of 91%.