Stephen Foldes

Dr. Stephen Foldes


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2016 in Science Translational Medicine
Verified
Journal Article
Closed access
PDF file
SFSharlene N. Flesher
Sharlene N. Flesher
JCJennifer L. Collinger
Jennifer L. Collinger
SFStephen Foldes
Stephen Foldes
JWJeffrey M. Weiss
Jeffrey M. Weiss
JDJohn E. Downey
John E. Downey
RGRobert A. Gaunt
Robert A. Gaunt
Tactile percepts were consistently elicited in the hand of a person with cervical spinal cord injury using intracortical microstimulation of the somatosensory cortex.

3 January 2007 in Journal of Computational Neuroscience
Verified
Journal Article
Closed access
PDF file
NBNiloy Bhadra
Niloy Bhadra
ELEmily A. Lahowetz
Emily A. Lahowetz
SFStephen Foldes
Stephen Foldes
KKKevin L. Kilgore
Kevin L. Kilgore

10 May 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SHShivayogi Hiremath
Shivayogi Hiremath
ETElizabeth C Tyler-Kabara
Elizabeth C Tyler-Kabara
JWJesse J Wheeler
Jesse J Wheeler
DMDaniel W Moran
Daniel W Moran
RGRobert A Gaunt
Robert A Gaunt
WWWei Wang
Wei Wang
Recent advancement in electrocorticography (ECoG)-based brain-computer interface technology has sparked a new interest in providing somatosensory feedback using ECoG electrodes, i.e., cortical surface electrodes. We conducted a 28-day study of cortical surface stimulation in an individual with arm paralysis due to brachial plexus injury to examine the sensation produced by electrical stimulation of the somatosensory cortex. A high-density ECoG grid was implanted over the somatosensory and motor cortices. Stimulation through cortical surface electrodes over the somatosensory cortex successfully elicited arm and hand sensations in our participant with chronic paralysis. There were three key findings. First, the intensity of perceived sensation increased monotonically with both pulse amplitude and pulse frequency. Second, changing pulse width changed the type of sensation based on qualitative description provided by the human participant. Third, the participant could distinguish between stimulation applied to two neighboring cortical surface electrodes, 4.5 mm center-to-center distance, for three out of seven electrode pairs tested. Taken together, we found that it was possible to modulate sensation intensity, sensation type, and evoke sensations across a range of locations from the fingers to the upper arm using different stimulation electrodes even in an individual with chronic impairment of somatosensory function. These three features are essential to provide effective somatosensory feedback for neuroprosthetic applications.

1 July 2013 in The Journal of Spinal Cord Medicine
Verified
Journal Article
Closed access
JCJennifer L. Collinger
Jennifer L. Collinger
SFStephen Foldes
Stephen Foldes
TBTim M. Bruns
Tim M. Bruns
BWBrian Wodlinger
Brian Wodlinger
RGRobert Gaunt
Robert Gaunt
DWDouglas J. Weber
Douglas J. Weber
Spinal cord injury (SCI) results in a loss of function and sensation below the level of the lesion. Neuroprosthetic technology has been developed to help restore motor and autonomic functions as well as to provide sensory feedback. This paper provides an overview of neuroprosthetic technology that aims to address the priorities for functional restoration as defined by individuals with SCI. We describe neuroprostheses that are in various stages of preclinical development, clinical testing, and commercialization including functional electrical stimulators, epidural and intraspinal microstimulation, bladder neuroprosthesis, and cortical stimulation for restoring sensation. We also discuss neural recording technologies that may provide command or feedback signals for neuroprosthetic devices. Neuroprostheses have begun to address the priorities of individuals with SCI, although there remains room for improvement. In addition to continued technological improvements, closing the loop between the technology and the user may help provide intuitive device control with high levels of performance.

1 September 2017 in Brain Connectivity
Verified
Journal Article
Open access
VBVarina L. Boerwinkle
Varina L. Boerwinkle
DMDeepankar Mohanty
Deepankar Mohanty
SFStephen Foldes
Stephen Foldes
DGDanielle Guffey
Danielle Guffey
CMCharles G. Minard
Charles G. Minard
DCDaniel J. Curry
Daniel J. Curry
The purpose of this study was to prospectively investigate the agreement between the epileptogenic zone(s) (EZ) localization by resting-state functional magnetic resonance imaging (rs-fMRI) and the seizure onset zone(s) (SOZ) identified by intracranial electroencephalogram (ic-EEG) using novel differentiating and ranking criteria of rs-fMRI abnormal independent components (ICs) in a large consecutive heterogeneous pediatric intractable epilepsy population without an a priori alternate modality informing EZ localization or prior declaration of total SOZ number. The EZ determination criteria were developed by using independent component analysis (ICA) on rs-fMRI in an initial cohort of 350 pediatric patients evaluated for epilepsy surgery over a 3-year period. Subsequently, these rs-fMRI EZ criteria were applied prospectively to an evaluation cohort of 40 patients who underwent ic-EEG for SOZ identification. Thirty-seven of these patients had surgical resection/disconnection of the area believed to be the primary source of seizures. One-year seizure frequency rate was collected postoperatively. Among the total 40 patients evaluated, agreement between rs-fMRI EZ and ic-EEG SOZ was 90% (36/40; 95% confidence interval [CI], 0.76–0.97). Of the 37 patients who had surgical destruction of the area believed to be the primary source of seizures, 27 (73%) rs-fMRI EZ could be classified as true positives, 7 (18%) false positives, and 2 (5%) false negatives. Sensitivity of rs-fMRI EZ was 93% (95% CI 78–98%) with a positive predictive value of 79% (95% CI, 63–89%). In those with cryptogenic localization-related epilepsy, agreement between rs-fMRI EZ and ic-EEG SOZ was 89% (8/9; 95% CI, 0.52–99), with no statistically significant difference between the agreement in the cryptogenic and symptomatic localization-related epilepsy subgroups. Two children with negative ic-EEG had removal of the rs-fMRI EZ and were seizure free 1 year postoperatively. Of the 33 patients where at least 1 rs-fMRI EZ agreed with the ic-EEG SOZ, 24% had at least 1 additional rs-fMRI EZ outside the resection area. Of these patients with un-resected rs-fMRI EZ, 75% continued to have seizures 1 year later. Conversely, among 75% of patients in whom rs-fMRI agreed with ic-EEG SOZ and had no anatomically separate rs-fMRI EZ, only 24% continued to have seizures 1 year later. This relationship between extraneous rs-fMRI EZ and seizure outcome was statistically significant ( p = 0.01). rs-fMRI EZ surgical destruction showed significant association with postoperative seizure outcome. The pediatric population with intractable epilepsy studied prospectively provides evidence for use of resting-state ICA ranking criteria, to identify rs-fMRI EZ, as developed by the lead author (V.L.B.). This is a high yield test in this population, because no seizure nor particular interictal epilepiform activity needs to occur during the study. Thus, rs-fMRI EZ detected by this technique are potentially informative for epilepsy surgery evaluation and planning in this population. Independent of other brain function testing modalities, such as simultaneous EEG-fMRI or electrical source imaging, contextual ranking of abnormal ICs of rs-fMRI localized EZs correlated with the gold standard of SOZ localization, ic-EEG, across the broad range of pediatric epilepsy surgery candidates, including those with cryptogenic epilepsy.

30 October 2018 in Epilepsia
Verified
Journal Article
Open access
PDF file
VBVarina L. Boerwinkle
Varina L. Boerwinkle
SFStephen Foldes
Stephen Foldes
STSalvatore J. Torrisi
Salvatore J. Torrisi
HTHamy Temkit
Hamy Temkit
WGWilliam D. Gaillard
William D. Gaillard
DCDaniel J. Curry
Daniel J. Curry
Summary: Objective: The purpose of this study is to investigate the outcomes of epilepsy surgery targeting the subcentimeter‐sized resting state functional magnetic resonance imaging (rs‐fMRI) epileptogenic onset zone (EZ) in hypothalamic hamartoma (HH).Methods: Fifty‐one children with HH‐related intractable epilepsy received anatomical MRI‐guided stereotactic laser ablation (SLA) procedures. Fifteen of these children were control subjects (CS) not guided by rs‐fMRI. Thirty‐six had been preoperatively guided by rs‐fMRI (RS) to determine EZs, which were subsequently targeted by SLA. The primary outcome measure for the study was a predetermined goal of 30% reduction in seizure frequency and improvement in class I Engel outcomes 1 year postoperatively. Quantitative and qualitative volumetric analyses of total HH and ablated tissue were also assessed.Results: In the RS group, the EZ target within the HH was ablated with high accuracy (>87.5% of target ablated in 83% of subjects). There was no difference between the groups in percentage of ablated hamartoma volume (P = 0.137). Overall seizure reduction was higher in the rs‐fMRI group: 85% RS versus 49% CS (P = 0.0006, adjusted). The Engel Epilepsy Surgery Outcome Scale demonstrated significant differences in those with freedom from disabling seizures (class I), 92% RS versus 47% CS, a 45% improvement (P = 0.001). Compared to prior studies, there was improvement in class I outcomes (92% vs 76%‐81%). No postoperative morbidity or mortality occurred.Significance: For the first time, surgical SLA targeting of subcentimeter‐sized EZs, located by rs‐fMRI, guided surgery for intractable epilepsy. Our outcomes demonstrated the highest seizure freedom rate without surgical complications and are a significant improvement over prior reports. The approach improved freedom from seizures by 45% compared to conventional ablation, regardless of hamartoma size or anatomical classification. This technique showed the same or reduced morbidity (0%) compared to recent non–rs‐fMRI‐guided SLA studies with as high as 20% permanent significant morbidity.