The increasing penetration levels of renewable distributed generation (RDG) into a power system have proven to bring both positive and negative impacts. The occurrence of under voltage at the far end of a conventional electrical distribution network (DN) may not raise concern anymore with RDGs integration into a power system. However, a penetration of RDGs into power system may cause problems such as voltage rise or over-voltage and reverse power flows at the Point of Common Coupling (PCC) between RDG and DN. This research paper presents the impact of voltage rise effect and reverse power flow constraint in power system with high concentration of RDG. The analysis is conducted on a sample DN, i.e., IEEE 13-bus test system, with RDG penetration by considering the most critical scenario such as low power demand in DN and a peak power injection by RDG. For studying the impact of voltage rise and reverse power flow, a mathematical model of a DN integrating RDG is developed. Furthermore, a controller incorporating an advance control-algorithm is proposed to be installed at PCC between DN and RDG to regulate the voltage rise effects and to mitigate the reverse power flow when operating at a worst critical scenario of minimum load and maximum generation from RDG. The proposed control strategy also mitigates the voltage–current harmonic distortions, improves the power factor, and maintain the voltage stability at PCC. The simulations are carried out using MATLAB/Simulink software. Finally, recommendations are provided for the power producers to counteract the effects of voltage rise at PCC. The study has demonstrated that, voltage at PCC can be sustained with a high concentration of RDG during a worst-case scenario without a reverse power flow and voltage rise beyond grid code limits.
The introduction of solar photovoltaic (PV) systems would provide electricity accessibility to rural areas that are far from or have no access to the grid system. Various countries are planning to reduce their emissions from fossil fuel, due to its negative effects, by substituting with renewable energy resources. The use of solar PV systems is expanding globally because of growing energy demands and depleting fossil fuel reserves. Grid integration of the solar system is expected to increase further in the near future. However, the power output of solar PV systems is inherently intermittent, and depends on the irradiance and the temperature operation of the solar cell, resulting in a wide range of defects. Hence, it is vital to extract peak power from the solar panel in all conditions to provide constant power to the load. This paper presents a tracking control method of the peak output power of a solar PV system connected to a DC-DC boost converter using an improved incremental conductance and integral regulator (IC + IR). The research was carried out because the solar PV output is dependent on environmental parameters, such as solar insolation and temperature. Therefore, it is pertinent to forecast the peak power point in outdoor conditions and to operate at that point, so that solar PV can produce the highest output each time it is used. A peak power point strategy that maximizes the output of a solar PV array is proposed. This method establishes the maximum output operation point under the effects of the solar insolation and the module temperature. An automatic converter restoration scheme with block/de-block signal control is proposed to protect the converters from the higher phase current, total capacitor voltage deviation, grid disturbance, and fault current. The proposed scheme also tracks the peak power point (PPP) of the solar array with stable output voltage under varying operating conditions. It reduces the error signal and ripples at the PPP during instantaneous and incremental conductance to zero. In addition, it controls the solar PV system under constantly changing climatic conditions, and thus improves the system efficiency.
Renewable Distributed Generation (RDG), when connected to a Distribution Network (DN), suffers from power quality issues because of the distorted currents drawn from the loads connected to the network over generation of active power injection at the Point of Common Coupling (PCC). This research paper presents the voltage rise regulation strategy at the PCC to enhance power quality and continuous operation of RDG, such as Photovoltaic Arrays (PVAs) connected to a DN. If the PCC voltage is not regulated, the penetration levels of the renewable energy integration to a DN will be limited or may be ultimately disconnected in the case of a voltage rise issue. The network is maintained in both unity power factor and voltage regulation mode, depending on the condition of the voltage fluctuation occurrences at the PCC. The research investigation shows that variation in the consumer’s loads (reduction) causes an increase in the power generated from the PVA, resulting in an increase in the grid current amplitude, reduction in the voltage of the feeder impedance and an increase in the phase voltage amplitude at the PCC. When the system is undergoing unity power factor mode, PCC voltage amplitude tends to rises with the loads. Its phase voltage amplitude rises above an acceptable range with no-loads which are not in agreement, as specified in the IEEE-1547 and Southern Africa grid code prerequisite. Incremental Conduction with Integral Regulator bases (IC + PI) are employed to access and regulate PVA generation, while the unwanted grid current distortions are attenuated from the network using an in-loop second order integral filtering circuit algorithm. Hence, the voltage rise at the PCC is mitigated through the generation of positive reactive power to the grid from the Distribution Static Compensator (DSTATCOM), thereby regulating the phase voltage. The simulation study is carried out in a MATLAB/Simulink environment for PVA performance.
17 March 2023 in WSEAS TRANSACTIONS ON POWER SYSTEMS
The recent innovation in power electronic application in the electrical power system (EPS) has given birth to an Improved Unified Power Quality Conditioner (IUPQC) that positively impacts the electrical power system (EPS). The previously available mitigation approaches with the application IUPQC are monotonous and are major designs for a particular power quality (PQ) issue which does not take care of the degree of impart. This paper presents an effective control architecture of an IUPQC design for sensitive loads in hybrid Photovoltaic Solar (PV) connected grid, concentrating on the voltage demand of loads that respond to slight changes. The objective of this work is to design a flexible controller that can respond to the different degrees of PQ challenges concerning voltage, variable load, and solar irradiation. It has combined the merits of an IUPQC and grid-integrated PV source. Effective controllers for Voltage Source Inverter (VSI) connected in series and Current Source Inverter (CSI) connected in shunt compensators of the UPQC are implemented to increase device strength for different voltage and current distortions. The series compensator was controlled using an enhanced Synchronous Reference Frame (SRF) technique based on adaptive notch filters. An Adaptive Logarithmic Absolute Algorithm (ALAL) was deployed for the parallel section of the proposed approach. The Mean Turning Filter (MTF) was used as a replacement for a low pass filter (LPF) for direct current node voltage management, leaving high and low-frequency ripples unaffected. To maintain a constant current on the grid side during grid disturbances, a feed-forward element has been introduced to the shunt CSI controller. Under various network situations, such as under-voltage, over-voltage, voltage distortion, harmonics, rapid load changes, and fluctuation in solar power, the control system performance is better as confirmed by experimental validation. Finally, it is observed that the voltage profile of 0.984 p.u. due to application control falling within the permissible limits. The proposed controllers are tested in the MATLAB Simulink on a developed distribution system model and validated experimental prototype.
30 June 2023 in WSEAS TRANSACTIONS ON POWER SYSTEMS
The recent modification in utilizing Multifunction Power Conditioner (MPC) such as Unified Power Quality Conditioner devices in power systems has led to different degrees of power losses, owing to electronic power impacts. This paper presents a detailed comparison of power loss analysis in various configurations of MPC, that is, the conventional unified power quality conditioner (UPQC) and the UPQC with distributed generation (〖UPQC〗_DG). The independent losses based on inverter design and distributed generation interfacing to the distribution form the basis for each configuration case. The investigation considered conventional UPQC as the base case for power losses, and the study was extended to 〖UPQC〗_DG at steady state operating condition. In all configurations, Switching Losses (SL) and conduction losses were considered using simulation studies carried out in MATLAB/SIMULINK, and the results obtained in all cases were used for comparative studies. Finally, the outcome indicates that the losses in 〖UPQC〗_DG is more than conventional UPQC based on simulation results in all cases.
The integration of solar and wind energy into the electrical grid has received global research attention due to their unpredictable characteristics. Because wind energy varies across all timescales of utility activity, renewable energy generation should be supplemented and enhanced, from real-time, minute-to-minute variations to annual alterations influencing long-term strategy. Wind energy generation does not only fluctuate but is also challenging to accurately forecast the timeframes of significance to electricity decision makers; day-ahead and long-term making plans of framework sufficiency such as meeting the network peak load annually. A utility that integrates wind and solar energy into its electricity mix would understand how to adapt to uncertainty and variability in operations while sustaining grid stability. Due to hydropower’s adaptability, a system using hydropower as one of its generating resources could be precisely adapted to absorb the variability of wind and solar energy. The objective of this research study is to create a hybrid system comprising hydro-wind and solar (Hybrid-HWS) integration for power balancing in an isolated electrical network in Klipkop village, Pretoria region, South Africa. The desirability of designing and building goaf storage tank in regard to capability, the fullness of line throughout water pumping, dispensing, storage tank spillage, and pressure difference throughout liquid flow within the storage tanks were preliminary assessed using geotechnical and weather forecasting data from a distinctive area of Klipkop town in Pretoria, South Africa. Different facility hours premised on daylight accessibility are scheduled to balance maximum load at early and late hours. However, in the scenario of electrical power, time shift requiring storage for extended periods of time, such as in terms of hours, Hybrid-HWS has been found to have a crucial role. The results of simulations showed a coordinated process design for Hybrid-HWS Energy Storage (ES) to determine everyday strategic planning in reducing the variability of the system resulting from wind-solar-pumped hydro ES output inadequacies and satisfy daily load demands. It could be recommended that by considering the adaptability characteristics, extremely rapidly, ramping, peaking support and maximum stabilizing aid of the system could be archived with pump-hydro into the energy mix which can provide specific guidelines for energy policymakers.