There have been considerable recent technological developments for implant overdenture attachments. This study presents an overview of the biomechanical and biomolecular aspects of various attachments for implant overdenture. Available articles on attachments for implant overdenture were reviewed from January 1980 to August 2021 in the ScienceDirect, MEDLINE/PubMed, and Web of Science resources, and relevant studies were included in this study. We focused on the following topics: attachment systems, retention of various attachments, stress distribution with different attachments, the design and fabrication of attachments, digital techniques in overdenture attachments, and the effects of attachments in peri-implant health. We found that plastic resin is commonly used for ball and bar attachments, whereas nylon resin is commonly used in locator attachments. The locator system offers a valuable attachment option for implant-retained overdenture. Attachment retention reduces while lateral force increases with implant inclination in overdenture. The higher the retention of an overdenture attachment, the higher the transferred stresses. Additionally, clip loading produces more stress in implants and precision elements than bar-retained dentures. As such, we conclude that the ball and locator systems the best overdenture systems due to their superior tissue response, survival rate, and patient satisfaction.
The aims of this systematic review were to evaluate the clinical masticatory performance of implant-supported restorations, observe the occlusal force changes in the distribution of the implant res...
This study prepared composites for core build-up containing Sr/F bioactive glass nanoparticles (Sr/F-BGNPs) and monocalcium phosphate monohydrate (MCPM) to prevent dental caries. The effect of the additives on the physical/mechanical properties of the materials was examined. Dual-cured resin composites were prepared using dimethacrylate monomers with added Sr/F-BGNPs (5 or 10 wt%) and MCPM (3 or 6 wt%). The additives reduced the light-activated monomer conversion by ~10%, but their effect on the conversion upon self-curing was negligible. The conversions of light-curing or self-curing polymerization of the experimental materials were greater than that of the commercial material. The additives reduced biaxial flexural strength (191 to 155 MPa), modulus (4.4 to 3.3), and surface microhardness (53 to 45 VHN). These values were comparable to that of the commercial material or within the acceptable range of the standard. The changes in the experimental composites’ mass and volume (~1%) were similar to that of the commercial comparison. The color change of the commercial material (1.0) was lower than that of the experimental composites (1.5–5.8). The addition of Sr/F-BGNPs and MCPM negatively affected the physical/mechanical properties of the composites, but the results were satisfactory except for color stability.
The hold phase of the stop consonants is crucial for a successful production of the release and the acoustic burst. Concurrently, it is also associated with weak acoustic energy and minimal movement, so that conventional acoustic and kinematic approaches are not relevant to investigate motor control. This paper presents an innovative experimental method to study speech motor control during this phase, based on meticulous measurement of the time variation of the mechanical pressure exerted by the tongue against the palate and also characterizing tongue–palate interaction. The concept is based on using miniature transducers with enhanced response characteristics inserted in different locations of the complete denture of edentulous subjects without perturbing the articulation. The study was done with a French-speaking adult whose maxillary denture was duplicated and mounted with six strain gauge transducers. The experiment was done with denti-alveolar and velar stop consonants with two vowel contexts. The results illustrate the potential of such device to analyse speech motor control when contact constrains tongue movements.
Objectives The mechanical interactions between tongue and palate are crucial for speech production and swallowing. In this study, we presented examples of pressure signals that can be recorded with our PRESLA system (PRESLA holds for the French expression “PRESsion de la LAngue” [Pressure from the tongue]) to assess these motor functions, and we illustrate which issues can be tackled with such a system. Materials and Methods A single French-speaking edentulous subject, old wearer of a complete denture, with no speech production and swallowing disorders, was recorded during the production of nonsense words including French alveolar fricatives, and during dry and water swallowing. The PRESLA system used strain-gauge transducers that were inserted into holes drilled in the palatal surface of a duplicate of the prosthesis at six locations that were relevant for speech production and swallowing. Pressure signals were postsynchronized with the motor tasks based on audio signals. Results Patterns of temporal variations of the pressure exerted by the tongue on the palate are shown for the two studied motor tasks. It is shown for our single subject that patterns for fricative /s/ are essentially bell shaped, whereas pressure signals observed for water swallow begin with a maximum followed by a slow decrease during the rest of the positive pressure phase. Pressure magnitude is almost 20 times larger for water swallow than for /s/ production. Conclusions This study illustrates the usefulness of our PRESLA system for studying speech production and swallowing motor control under normal and pathological conditions.
Étude et mesure de la pression mécanique exercée par la langue sur une prothèse adjointe au coirs de la production de la parole et lors de la déglutition: L'objectif de cette thèse est l'étude des interactions mécaniques entre la langue et le palais dans la production de parole et la déglutition. Cette interaction est cruciale car elle détermine la morphologie de la langue et son évolution dans le temps avant et après les contacts. Elle ne peut cependant pas être étudiée avec des approches cinématiques conventionnelles, car l'amplitude des mouvements est trop faible. La première partie de la thèse est consacrée à la conception d'un dispositif expérimental permettant de mesurer ces interactions sans perturber l'appareil vocal. La première particularité est que le dispositif est utilisé sur des patients édentés appareillés. Nous utilisons un duplicata de la prothèse complète maxillaire pour insérer des capteurs miniatures à jauges de contrainte dont les caractéristiques de réponse sont optimisées et qui permettent de mesurer la pression mécanique exercée par la langue sur le palais. La seconde particularité est qu’il existe une procédure d'étalonnage, associée aux capteurs, qui utilise une Colonne d’Eau Sèche. Elle applique une pression sur le capteur via une membrane en latex déformable, capable de simuler le comportement visco-élastique de la langue sur le palais. La deuxième partie de la thèse décrit le protocole de recherche clinique visant à (1) caractériser l'interaction langue-palais au cours de la prononciation et de la déglutition normales sur des individus édentés que nous considérons adaptés à leur prothèse complète (Cohorte 1), (2) observer l'adaptation dans une étude longitudinale des patients édentés nouvellement appareillés (Cohorte 2). Ce projet comprend, pour les deux cohortes, la description des objectifs, le protocole expérimental, la description fine des paramètres pertinents et la méthode statistique de traitement des données. Toutefois, le processus de rédaction et de soumission de ce protocole à un Comité de Protection des Personnes (CPP) a été plus long que prévu et l’étude clinique n’a pu être menée dans le cadre de cette thèse. C’est pourquoi, dans la troisième partie de la thèse, nous avons utilisé les données enregistrées dans l’étude de faisabilité, auprès d'un adulte édenté francophone. Les résultats montrent que notre dispositif permet d'explorer des hypothèses théoriques cruciales dans la parole comme l'existence de cibles virtuelles au-dessus du palais ou le rôle du palais dans la mise en forme du conduit aérien des consonnes fricatives. Les résultats des données enregistrées lors de la déglutition sont moins clairs, mais l'enchaînement temporel précis des contacts peut être décrit, ce qui permet de préciser comment les mouvements ondulatoires de la langue pendant la phase orale de la déglutition exploitent les contacts avec le palais. Les retombées cliniques de cette thèse permettent une meilleure connaissance du rôle fonctionnel des prothèses complètes et d’envisager la conception de prothèses qui seraient adaptées aux spécificités de chaque patient, notamment pour la rééducation des sujets traités chirurgicalement après des cancers de la langue, dans le cadre des taches de production de parole et de déglutition
About Me
Lecturer
Department of Periodontics and Implant Dentistry
Faculty of Dentistry
Thammasat University
Thailand
Lecturer
Department of Periodontics and Implant Dentistry
Faculty of Dentistry
Thammasat University
Thailand