Diego Marcos-Martínez

Mr. Diego Marcos-Martínez

Biomedical Engineering Group
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2022 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
SPSergio Perez-Velasco
Sergio Perez-Velasco
ESEduardo Santamaria-Vazquez
Eduardo Santamaria-Vazquez
Víctor Martínez-CagigalVíctor Martínez-Cagigal
Víctor Martínez-Cagigal
DMDiego Marcos-Martínez
Diego Marcos-Martínez
Roberto HorneroRoberto Hornero
Roberto Hornero
In this study, we present a new Deep Learning (DL) architecture for Motor Imagery (MI) based Brain Computer Interfaces (BCIs) called EEGSym . Our implementation aims to improve previous state-of-the-art performances on MI classification by overcoming inter-subject variability and reducing BCI inefficiency, which has been estimated to affect 10-50% of the population. This convolutional neural network includes the use of inception modules, residual connections and a design that introduces the symmetry of the brain through the mid-sagittal plane into the network architecture. It is complemented with a data augmentation technique that improves the generalization of the model and with the use of transfer learning across different datasets. We compare EEGSym ’s performance on inter-subject MI classification with ShallowConvNet, DeepConvNet, EEGNet and EEG-Inception. This comparison is performed on 5 publicly available datasets that include left or right hand motor imagery of 280 subjects. This population is the largest that has been evaluated in similar studies to date. EEGSym significantly outperforms the baseline models reaching accuracies of 88.6±9.0 on Physionet, 83.3±9.3 on OpenBMI, 85.1±9.5 on Kaya2018, 87.4±8.0 on Meng2019 and 90.2±6.5 on Stieger2021. At the same time, it allows 95.7% of the tested population (268 out of 280 users) to reach BCI control (≥70% accuracy). Furthermore, these results are achieved using only 16 electrodes of the more than 60 available on some datasets. Our implementation of EEGSym , which includes new advances for EEG processing with DL, outperforms previous state-of-the-art approaches on inter-subject MI classification.

16 January 2023 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
ESEduardo Santamaría-Vázquez
Eduardo Santamaría-Vázquez
Víctor Martínez-CagigalVíctor Martínez-Cagigal
Víctor Martínez-Cagigal
DMDiego Marcos-Martínez
Diego Marcos-Martínez
VRVictor Rodriguez
Victor Rodriguez
SPSergio Pérez-Velasco
Sergio Pérez-Velasco
Roberto HorneroRoberto Hornero
Roberto Hornero
Neurotechnologies have great potential to transform our society in ways that are yet to be uncovered. The rate of development in this field has increased significantly in recent years, but there are still barriers that need to be overcome before bringing neurotechnologies to the general public. One of these barriers is the difficulty of performing experiments that require complex software, such as brain-computer interfaces (BCI) or cognitive neuroscience experiments. Current platforms have limitations in terms of functionality and flexibility to meet the needs of researchers, who often need to implement new experimentation settings. This work was aimed to propose a novel software ecosystem, called MEDUSA©, to overcome these limitations. We followed strict development practices to optimize MEDUSA© for research in BCI and cognitive neuroscience, making special emphasis in the modularity, flexibility and scalability of our solution. Moreover, it was implemented in Python, an open-source programming language that reduces the development cost by taking advantage from its high-level syntax and large number of community packages. MEDUSA© provides a complete suite of signal processing functions, including several deep learning architectures or connectivity analysis, and ready-to-use BCI and neuroscience experiments, making it one of the most complete solutions nowadays. We also put special effort in providing tools to facilitate the development of custom experiments, which can be easily shared with the community through an app market available in our website to promote reproducibility. MEDUSA© is a novel software ecosystem for modern BCI and neurotechnology experimentation that provides state-of-the-art tools and encourages the participation of the community to make a difference for the progress of these fields. Visit the official website at https://www.medusabci.com/ to know more about this project.

15 June 2023 in Expert Systems with Applications
Verified
Journal Article
Open access
Víctor Martínez-CagigalVíctor Martínez-Cagigal
Víctor Martínez-Cagigal
ESEduardo Santamaría-Vázquez
Eduardo Santamaría-Vázquez
SPSergio Pérez-Velasco
Sergio Pérez-Velasco
DMDiego Marcos-Martínez
Diego Marcos-Martínez
SMSelene Moreno-Calderón
Selene Moreno-Calderón
Roberto HorneroRoberto Hornero
Roberto Hornero

25 November 2021 in Entropy
Verified
Journal Article
Open access
PDF file
DMDiego Marcos-Martínez
Diego Marcos-Martínez
Víctor Martínez-CagigalVíctor Martínez-Cagigal
Víctor Martínez-Cagigal
ESEduardo Santamaría-Vázquez
Eduardo Santamaría-Vázquez
SPSergio Pérez-Velasco
Sergio Pérez-Velasco
Roberto HorneroRoberto Hornero
Roberto Hornero
Neurofeedback training (NFT) has shown promising results in recent years as a tool to address the effects of age-related cognitive decline in the elderly. Since previous studies have linked reduced complexity of electroencephalography (EEG) signal to the process of cognitive decline, we propose the use of non-linear methods to characterise changes in EEG complexity induced by NFT. In this study, we analyse the pre- and post-training EEG from 11 elderly subjects who performed an NFT based on motor imagery (MI–NFT). Spectral changes were studied using relative power (RP) from classical frequency bands (delta, theta, alpha, and beta), whilst multiscale entropy (MSE) was applied to assess EEG-induced complexity changes. Furthermore, we analysed the subject’s scores from Luria tests performed before and after MI–NFT. We found that MI–NFT induced a power shift towards rapid frequencies, as well as an increase of EEG complexity in all channels, except for C3. These improvements were most evident in frontal channels. Moreover, results from cognitive tests showed significant enhancement in intellectual and memory functions. Therefore, our findings suggest the usefulness of MI–NFT to improve cognitive functions in the elderly and encourage future studies to use MSE as a metric to characterise EEG changes induced by MI–NFT.

6 January 2022 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
ESEduardo Santamaría-Vázquez
Eduardo Santamaría-Vázquez
Víctor Martínez-CagigalVíctor Martínez-Cagigal
Víctor Martínez-Cagigal
SPSergio Pérez-Velasco
Sergio Pérez-Velasco
DMDiego Marcos-Martínez
Diego Marcos-Martínez
Roberto HorneroRoberto Hornero
Roberto Hornero
Brain-computer interfaces (BCI) based on event-related potentials (ERP) are a promising technology for alternative and augmented communication in an assistive context. However, most approaches to date are synchronous, requiring the intervention of a supervisor when the user wishes to turn his attention away from the BCI system. In order to bring these BCIs into real-life applications, a robust asynchronous control of the system is required through monitoring of user attention. Despite the great importance of this limitation, which prevents the deployment of these systems outside the laboratory, it is often overlooked in research articles. This study was aimed to propose a novel method to solve this problem, taking advantage of deep learning for the first time in this context to overcome the limitations of previous strategies based on hand-crafted features. The proposed method, based on EEG-Inception, a novel deep convolutional neural network, divides the problem in 2 stages to achieve the asynchronous control: (i) the model detects user's control state, and (ii) decodes the command only if the user is attending to the stimuli. Additionally, we used transfer learning to reduce the calibration time, even exploring a calibration-less approach. Our method was evaluated with 22 healthy subjects, analyzing the impact of the calibration time and number of stimulation sequences on the system's performance. For the control state detection stage, we report average accuracies above 91% using only 1 sequence of stimulation and 30 calibration trials, reaching a maximum of 96.95% with 15 sequences. Moreover, our calibration-less approach also achieved suitable results, with a maximum accuracy of 89.36%, showing the benefits of transfer learning. As for the overall asynchronous system, which includes both stages, the maximum information transfer rate was 35.54 bpm, a suitable value for high-speed communication. The proposed strategy achieved higher performance with less calibration trials and stimulation sequences than former approaches, representing a promising step forward that paves the way for more practical applications of ERP-based spellers.

9 May 2023 in Computers in Biology and Medicine
Verified
Journal Article
Open access
DMDiego Marcos-Martínez
Diego Marcos-Martínez
ESEduardo Santamaría-Vázquez
Eduardo Santamaría-Vázquez
Víctor Martínez-CagigalVíctor Martínez-Cagigal
Víctor Martínez-Cagigal
SPSergio Pérez-Velasco
Sergio Pérez-Velasco
VRVictor Rodriguez
Victor Rodriguez
Roberto HorneroRoberto Hornero
Roberto Hornero
Neurofeedback (NF) is a paradigm that allows users to self-modulate patterns of brain activity. It is implemented with a closed-loop brain-computer interface (BCI) system that analyzes the user's brain activity in real-time and provides continuous feedback. This paradigm is of great interest due to its potential as a non-pharmacological and non-invasive alternative to treat non-degenerative brain disorders. Nevertheless, currently available NF frameworks have several limitations, such as the lack of a wide variety of real-time analysis metrics or overly simple training scenarios that may negatively affect user performance. To overcome these limitations, this work proposes ITACA: a novel open-source framework for the design, implementation and evaluation of NF training paradigms. ITACA is designed to be easy-to-use, flexible and attractive. Specifically, ITACA includes three different gamified training scenarios with a choice of five brain activity metrics as real-time feedback. Among them, novel metrics based on functional connectivity and network theory stand out. It is complemented with five different computerized versions of widespread cognitive assessment tests. To validate the proposed framework, a computational efficiency analysis and an NF training protocol focused on frontal-medial theta modulation were conducted. Efficiency analysis proved that all implemented metrics allow an optimal feedback update rate for conducting NF sessions. Furthermore, conducted NF protocol yielded results that support the use of ITACA in NF research studies. ITACA implements a wide variety of features for designing, conducting and evaluating NF studies with the goal of helping researchers expand the current state-of-the-art in NF training.