The aim of this study was to evaluate particle enhanced turbidimetric inhibition immunoassay (PETINIA) recently developed for mycophenolic acid (MPA) determination in plasma and to compare it with a reference high-performance liquid chromatography (HPLC) method, using samples from heart transplant recipients. The results are presented in the context of PETINIA being compared with enzyme multiplied immunoassay technique (EMIT). PETINIA evaluation was performed using 194 routine trough plasma samples at steady state. EMIT was evaluated using 677 samples from 61 steady-state 12-hour profiles obtained from 35 heart transplant patients. Evaluation was undertaken on a Dimension EXL 200 analyzer (PETINIA) and on a Viva-E analyzer (EMIT). The mean MPA concentration measured by PETINIA was significantly higher than that measured by high-performance liquid chromatography combined with UV detector (2.36 ± 1.30 mcg/mL versus 1.82 ± 1.23 mcg/mL, respectively, P < 0.0001). Bland-Altman analysis revealed a mean bias of 0.54 mcg/mL [95% confidence interval (CI), 0.49-0.59] comprising 33.48% (95% CI, 30.34-36.61). Passing-Bablok regression was: y = 1.100x + 0.38 (95% CI for slope: 1.044-1.154 and for intercept: 0.30-0.47). Regardless of a significant observed correlation (r = 0.9230, P < 0.0001), the statistical analyses showed a significant difference between PETINIA and the reference chromatographic method. The mean MPA concentration measured by EMIT was significantly higher than that measured by HPLC (7.48 ± 8.34 mcg/mL versus 5.57 ± 6.61 mcg/mL, respectively, P < 0.0001) with a mean bias of 1.91 mcg/mL (95% CI, 1.75-2.07) comprising 35.91% (95% CI, 34.37-37.45). The significant difference between EMIT and HPLC was confirmed by Passing-Bablok regression: y = 1.300x + 0.24 (95% CI for slope: 1.279-1.324 and for intercept: 0.18-0.29). The analysis of the determinations, grouped by sampling time, revealed positive bias between EMIT and HPLC ranging from 24.54% to 42.77% and inversely proportional to MPA concentrations with r = 0.9122 (P < 0.001). The new immunochemical PETINIA method was associated with significantly higher MPA concentrations in routine therapeutic drug monitoring samples from heart transplant patients. The magnitude of the MPA overestimation was similar to that observed by use of the EMIT method.


28 September 2021 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
MBMagdalena Anna Bodnar-Broniarczyk
Magdalena Anna Bodnar-Broniarczyk
MDMagdalena Durlik
Magdalena Durlik
TBTeresa Bączkowska
Teresa Bączkowska
KCKatarzyna Czerwińska
Katarzyna Czerwińska
RMRyszard Marszałek
Ryszard Marszałek
EGEdyta Gilant
Edyta Gilant
Tacrolimus (TAC) has a narrow therapeutic index and highly variable pharmacokinetic characteristics. Close monitoring of the TAC concentrations is required in order to avoid the risk of acute rejection or adverse drug reaction. The results in some studies indicate that inter-tissue TAC concentrations can be a better predictor with regards to acute rejection episode than TAC concentration in whole blood. Therefore, the aim of the study was to assess the correlation between dosage, blood, hepatic and kidney tissue concentration of TAC measured by a validated liquid chromatography tandem mass spectrometry (LC-MS/MS) and clinical outcomes in a larger cohort of 100 liver and renal adult transplant recipients. Dried biopsies were weighed, mechanically homogenized and then the samples were treated with a mixture of zinc sulfate—acetonitrile to perform protein precipitation. After centrifugation, the extraction with tert-butyl methyl ether was performed. The analytical range was proven for TAC tissue concentrations of 10–400 pg/mg. The accuracy and precision fell within the acceptance criteria for intraday as well as interday assay. There was no correlation between dosage, blood (C0) and tissue TAC concentrations. TAC concentrations determined in liver and kidney biopsies ranged from 8.5 pg/mg up to 160.0 pg/mg and from 7.1 pg/mg up to 215.7 pg/mg, respectively. To the best of our knowledge, this is the first LC-MS/MS method for kidney and liver tissue TAC monitoring using Tac13C,D2 as the internal standard, which permits measuring tissue TAC concentrations as low as 10 pg/mg.