Representative Publications

View All Publications
1 April 2016 in Therapeutic Drug Monitoring
Verified
Journal Article
Closed access
CSChristoph Seger
Christoph Seger
MSMaria Shipkova
Maria Shipkova
UCUwe Christians
Uwe Christians
EBElaine M. Billaud
Elaine M. Billaud
PWPing Wang
Ping Wang
PWPierre Wallemacq
Pierre Wallemacq
Monitoring immunosuppressive drugs (ISDs) in blood or plasma is still a key therapeutic drug monitoring (TDM) application in clinical settings. Narrow target ranges and severe side effects at drug underexposure or overexposure make accurate and precise measurements a must. This overview prepared by the Immunosuppressive Drugs Scientific Committee of the International Association of Therapeutic Drug Monitoring and Clinical Toxicology is intended to serve as a summary and guidance document describing the current state-of-the-art in the TDM of ISDs.

1 April 2016 in Therapeutic Drug Monitoring
Verified
Journal Article
Closed access
MSMaria Shipkova
Maria Shipkova
DHDennis A. Hesselink
Dennis A. Hesselink
DHDavid W. Dsc(Med) Holt
David W. Dsc(Med) Holt
EBEliane M. Billaud
Eliane M. Billaud
TGTeun van Gelder
Teun van Gelder
PMPierre Marquet
Pierre Marquet
In 2014, the Immunosuppressive Drugs Scientific Committee of the International Association of Therapeutic Drug Monitoring and Clinical Toxicology called a meeting of international experts to provide recommendations to guide therapeutic drug monitoring (TDM) of everolimus (EVR) and its optimal use in clinical practice. EVR is a potent inhibitor of the mammalian target of rapamycin, approved for the prevention of organ transplant rejection and for the treatment of various types of cancer and tuberous sclerosis complex. EVR fulfills the prerequisites for TDM, having a narrow therapeutic range, high interindividual pharmacokinetic variability, and established drug exposure–response relationships. EVR trough concentrations (C0) demonstrate a good relationship with overall exposure, providing a simple and reliable index for TDM. Whole-blood samples should be used for measurement of EVR C0, and sampling times should be standardized to occur within 1 hour before the next dose, which should be taken at the same time everyday and preferably without food. In transplantation settings, EVR should be generally targeted to a C0 of 3–8 ng/mL when used in combination with other immunosuppressive drugs (calcineurin inhibitors and glucocorticoids); in calcineurin inhibitor-free regimens, the EVR target C0 range should be 6–10 ng/mL. Further studies are required to determine the clinical utility of TDM in nontransplantation settings. The choice of analytical method and differences between methods should be carefully considered when determining EVR concentrations, and when comparing and interpreting clinical trial outcomes. At present, a fully validated liquid chromatography tandem mass spectrometry assay is the preferred method for determination of EVR C0, with a lower limit of quantification close to 1 ng/mL. Use of certified commercially available whole-blood calibrators to avoid calibration bias and participation in external proficiency-testing programs to allow continuous cross-validation and proof of analytical quality are highly recommended. Development of alternative assays to facilitate on-site measurement of EVR C0 is encouraged.

1 May 2001 in Journal of Chromatography B: Biomedical Sciences and Applications
Verified
Journal Article
Closed access
PKPaweł K. Kunicki
Paweł K. Kunicki

1 June 2015 in Therapeutic Drug Monitoring
Verified
Journal Article
Closed access
PKPaweł K. Kunicki
Paweł K. Kunicki
EGEdyta Gilant
Edyta Gilant
ABAleksandra Boczek
Aleksandra Boczek
JWJoanna Waś
Joanna Waś
MBMagdalena Anna Bodnar-Broniarczyk
Magdalena Anna Bodnar-Broniarczyk
The aim of this study was to evaluate particle enhanced turbidimetric inhibition immunoassay (PETINIA) recently developed for mycophenolic acid (MPA) determination in plasma and to compare it with a reference high-performance liquid chromatography (HPLC) method, using samples from heart transplant recipients. The results are presented in the context of PETINIA being compared with enzyme multiplied immunoassay technique (EMIT). PETINIA evaluation was performed using 194 routine trough plasma samples at steady state. EMIT was evaluated using 677 samples from 61 steady-state 12-hour profiles obtained from 35 heart transplant patients. Evaluation was undertaken on a Dimension EXL 200 analyzer (PETINIA) and on a Viva-E analyzer (EMIT). The mean MPA concentration measured by PETINIA was significantly higher than that measured by high-performance liquid chromatography combined with UV detector (2.36 ± 1.30 mcg/mL versus 1.82 ± 1.23 mcg/mL, respectively, P < 0.0001). Bland-Altman analysis revealed a mean bias of 0.54 mcg/mL [95% confidence interval (CI), 0.49-0.59] comprising 33.48% (95% CI, 30.34-36.61). Passing-Bablok regression was: y = 1.100x + 0.38 (95% CI for slope: 1.044-1.154 and for intercept: 0.30-0.47). Regardless of a significant observed correlation (r = 0.9230, P < 0.0001), the statistical analyses showed a significant difference between PETINIA and the reference chromatographic method. The mean MPA concentration measured by EMIT was significantly higher than that measured by HPLC (7.48 ± 8.34 mcg/mL versus 5.57 ± 6.61 mcg/mL, respectively, P < 0.0001) with a mean bias of 1.91 mcg/mL (95% CI, 1.75-2.07) comprising 35.91% (95% CI, 34.37-37.45). The significant difference between EMIT and HPLC was confirmed by Passing-Bablok regression: y = 1.300x + 0.24 (95% CI for slope: 1.279-1.324 and for intercept: 0.18-0.29). The analysis of the determinations, grouped by sampling time, revealed positive bias between EMIT and HPLC ranging from 24.54% to 42.77% and inversely proportional to MPA concentrations with r = 0.9122 (P < 0.001). The new immunochemical PETINIA method was associated with significantly higher MPA concentrations in routine therapeutic drug monitoring samples from heart transplant patients. The magnitude of the MPA overestimation was similar to that observed by use of the EMIT method.

1 December 2012 in Journal of Chromatography B
Verified
Journal Article
Closed access
PKPaweł K. Kunicki
Paweł K. Kunicki
JWJoanna Waś
Joanna Waś

1 February 2009 in Journal of Clinical Pharmacy and Therapeutics
Verified
Journal Article
Closed access
PDF file
EGEdyta Gilant
Edyta Gilant
PKPaweł K. Kunicki
Paweł K. Kunicki
MSM. Sobieszczanska-Malek
M. Sobieszczanska-Malek
BGB. Gralak
B. Gralak
ISI. Szlaska
I. Szlaska