Vicentiu Mircea Saceleanu

Dr. Vicentiu Mircea Saceleanu

Neurosurgery, Lucian Blaga University of Sibiu, Sibiu, Romania

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
ACAlexandru Vladimir Ciurea
Alexandru Vladimir Ciurea
AMAurel George Mohan
Aurel George Mohan
RCRazvan Adrian Covache-Busuioc
Razvan Adrian Covache-Busuioc
HCHoria Petre Costin
Horia Petre Costin
LGLuca Andrei Glavan
Luca Andrei Glavan
VSVicentiu Mircea Saceleanu
Vicentiu Mircea Saceleanu
Neurodegenerative diseases are, according to recent studies, one of the main causes of disability and death worldwide. Interest in molecular genetics has started to experience exponential growth thanks to numerous advancements in technology, shifts in the understanding of the disease as a phenomenon, and the change in the perspective regarding gene editing and the advantages of this action. The aim of this paper is to analyze the newest approaches in genetics and molecular sciences regarding four of the most important neurodegenerative disorders: Alzheimer’s disease, Parkinson’s disease, Huntington’s disease, and amyotrophic lateral sclerosis. We intend through this review to focus on the newest treatment, diagnosis, and predictions regarding this large group of diseases, in order to obtain a more accurate analysis and to identify the emerging signs that could lead to a better outcome in order to increase both the quality and the life span of the patient. Moreover, this review could provide evidence of future possible novel therapies that target the specific genes and that could be useful to be taken into consideration when the classical approaches fail to shed light.

30 June 2019 in Materials
Verified
Journal Article
Open access
PDF file
MMMarioara Moldovan
Marioara Moldovan
RBRobert Balazsi
Robert Balazsi
Andrada SoancaAndrada Soanca
Andrada Soanca
Ruxandra-Mioara RajnoveanuRuxandra-Mioara Rajnoveanu
Ruxandra-Mioara Rajnoveanu
CODRUTA SAROSICODRUTA SAROSI
CODRUTA SAROSI
ICIoan Cristescu
Ioan Cristescu
The novelty of this study consists in the formulation and characterization of three experimental dental composites (PM, P14M, P2S) for cervical dental lesion restoration compared to the commercial composites Enamel plus HRi® - En (Micerium S.p.A, Avengo, Ge, Italy), G-ænial Anterior® - Ge, (GC Europe N.V., Leuven, Belgium), Charisma® - Ch (Heraeus Kulzer, Berkshire, UK). The physio-chemical properties were studied, like the degree of conversion and the residual monomers in cured samples using FTIR-ATR (attenuated total reflectance) and HPLC-UV (ultraviolet detection), as well as the evaluation of the mechanical properties of the materials. The null hypothesis was that there would be no differences between experimental and commercial resin composites regarding the evaluated parameters. Statistical analysis revealed that water and saliva storage induced significant modifications of all mechanical parameters after three months for all tested materials, except for a few comparisons for each type of material. Storage medium seemed not to alter the values of mechanical parameters in comparison with the initial ones for: diametral tensile strength (DTS-saliva for Ge and PM, compressive strength (CS)-water for Ch, DTS-water and Young’s modulus YM-saliva for P14M and YM-water/ saliva for P2S (p > 0.05). Two of the experimental materials showed less than 1% residual monomers, which sustains good polymerization efficiency. Experimental resin composites have good mechanical properties, which makes them recommendable for the successful use in load-bearing surfaces of posterior teeth.

23 September 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
VSVicentiu Mircea Saceleanu
Vicentiu Mircea Saceleanu
CTCorneliu Toader
Corneliu Toader
HPHoria Ples
Horia Ples
RCRazvan Adrian Covache-Busuioc
Razvan Adrian Covache-Busuioc
HCHoria Petre Costin
Horia Petre Costin
ACAlexandru Vladimir Ciurea
Alexandru Vladimir Ciurea
Among the high prevalence of cerebrovascular diseases nowadays, acute ischemic stroke stands out, representing a significant worldwide health issue with important socio-economic implications. Prompt diagnosis and intervention are important milestones for the management of this multifaceted pathology, making understanding the various stroke-onset symptoms crucial. A key role in acute ischemic stroke management is emphasizing the essential role of a multi-disciplinary team, therefore, increasing the efficiency of recognition and treatment. Neuroimaging and neuroradiology have evolved dramatically over the years, with multiple approaches that provide a higher understanding of the morphological aspects as well as timely recognition of cerebral artery occlusions for effective therapy planning. Regarding the treatment matter, the pharmacological approach, particularly fibrinolytic therapy, has its merits and challenges. Endovascular thrombectomy, a game-changer in stroke management, has witnessed significant advances, with technologies like stent retrievers and aspiration catheters playing pivotal roles. For select patients, combining pharmacological and endovascular strategies offers evidence-backed benefits. The aim of our comprehensive study on acute ischemic stroke is to efficiently compare the current therapies, recognize novel possibilities from the literature, and describe the state of the art in the interdisciplinary approach to acute ischemic stroke. As we aspire for holistic patient management, the emphasis is not just on medical intervention but also on physical therapy, mental health, and community engagement. The future holds promising innovations, with artificial intelligence poised to reshape stroke diagnostics and treatments. Bridging the gap between groundbreaking research and clinical practice remains a challenge, urging continuous collaboration and research.

9 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
Baltatu Madalina SimonaBaltatu Madalina Simona
Baltatu Madalina Simona
Petrica VizureanuPetrica Vizureanu
Petrica Vizureanu
Andrei Victor SanduAndrei Victor Sandu
Andrei Victor Sandu
NSNestor Ruben Florido Suarez
Nestor Ruben Florido Suarez
VSVicentiu Mircea Saceleanu
Vicentiu Mircea Saceleanu
Julia C. Mirza-RoscaJulia C. Mirza-Rosca
Julia C. Mirza-Rosca
Titanium alloys are used in medical devices due to their mechanical properties, but also for their corrosion resistance. The natural passivation of titanium-based biomaterials, on the surface of which a dense and coherent film of nanometric thickness is formed, composed mainly of TiO2, determines an apparent bioactivity of them. In this paper, the method of obtaining new Ti20MoxSi alloys (x = 0.0, 0.5, 0.75, and 1.0) is presented, their microstructure is analyzed, and their electrochemical responses in Ringer´s solution were systematically investigated by linear polarization, cyclic potential dynamic polarization, and electrochemical impedance spectroscopy (EIS). The alloys corrosion resistance is high, and no evidence of localized breakdown of the passive layer was observed. There is no regularity determined by the composition of the alloys, in terms of corrosion resistance, but it seems that the most resistant is Ti20Mo1.0Si.

8 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
PSPedro P. Socorro-Perdomo
Pedro P. Socorro-Perdomo
NSNestor Ruben Florido Suarez
Nestor Ruben Florido Suarez
Julia C. Mirza-RoscaJulia C. Mirza-Rosca
Julia C. Mirza-Rosca
VSVicentiu Mircea Saceleanu
Vicentiu Mircea Saceleanu
The increased popularity of Ti and its alloys as important biomaterials is driven by their low modulus, greater biocompatibility, and better corrosion resistance in comparison to traditional biomaterials, such as stainless steel and Co–Cr alloys. Ti alloys are successfully used in severe stress situations, such as Ti–6Al–4V, but this alloy is related to long-term health problems and, in response, different Ti alloys composed of non-toxic and non-allergic elements such as Nb, Zr, Mo, and Ta have been developed for biomedical applications. In this context, binary alloys of titanium and tantalum have been developed and are predicted to be potential products for medical purposes. More than this, today, novel biocompatible alloys such as high entropy alloys with Ti and Ta are considered for biomedical applications and therefore it is necessary to clarify the influence of tantalum on the behavior of the alloy. In this study, various Ti–xTa alloys (with x = 5, 15, 25, and 30) were characterized using different techniques. High-resolution maps of the materials’ surfaces were generated by scanning tunneling microscopy (STM), and atom distribution maps were obtained by energy dispersive X-ray spectroscopy (EDS). A thorough output of chemical composition, and hence the crystallographic structure of the alloys, was identified by X-ray diffraction (XRD). Additionally, the electrochemical behavior of these Ti–Ta alloys was investigated by EIS in simulated body fluid at different potentials. The passive layer resistance increases with the potential due to the formation of the passive layer of TiO2 and Ta2O5 and then decreases due to the dissolution processes through the passive film. Within the Ti–xTa alloys, Ti–25Ta demonstrates excellent passive layer and corrosion resistance properties, so it seems to be a promising product for metallic medical devices.

6 April 2019 in Materials
Verified
Journal Article
Open access
PDF file
Antoniac IulianAntoniac Iulian
Antoniac Iulian
Dan Ioan STOIADan Ioan STOIA
Dan Ioan STOIA
BGBrandusa Ghiban
Brandusa Ghiban
CTCamelia Tecu
Camelia Tecu
Florin MiculescuFlorin Miculescu
Florin Miculescu
VSVicentiu Mircea Saceleanu
Vicentiu Mircea Saceleanu
A case study of a failed humeral shaft locking compression plate is presented, starting with a clinical case where failure occurred and an implant replacement was required. This study uses finite element method (FEM) in order to determine the failure modes for the clinical case. Four loading scenarios that simulate daily life activities were considered for determining the stress distribution in a humeral shaft locking compression plate (LCP). Referring to the simulation results, the failure analysis was performed on the explant. Using fracture surface investigation methods, stereomicroscopy and scanning electron microscopy (SEM), a mixed mode failure was determined. An initial fatigue failure occurred followed by a sudden failure of the plate implant as a consequence of patient’s fall. The fracture morphology was mostly masked by galling; the fractured components were in a sliding contact. Using information from simulations, the loading was inferred and correlated with fracture site and surface features.