Baltatu Madalina Simona

Dr. Baltatu Madalina Simona

Faculty of Materials Science and Engineering, Technical University "Gheorghe Asachi" of Iasi, Iasi, Romania
+1
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2023 in Materials
Verified
Journal Article
Open access
PDF file
LKLingyun Kong
Lingyun Kong
ZHZahra Heydari Heydari
Zahra Heydari Heydari
GLGhadeer Hazim Lami
Ghadeer Hazim Lami
Abbas SaberiAbbas Saberi
Abbas Saberi
Baltatu Madalina SimonaBaltatu Madalina Simona
Baltatu Madalina Simona
Petrica VizureanuPetrica Vizureanu
Petrica Vizureanu
Zinc (Zn)-based biodegradable materials show moderate degradation rates in comparison with other biodegradable materials (Fe and Mg). Biocompatibility and non-toxicity also make them a viable option for implant applications. Furthermore, Pure Zn has poor mechanical behavior, with a tensile strength of around 100–150 MPa and an elongation of 0.3–2%, which is far from reaching the strength required as an orthopedic implant material (tensile strength is more than 300 MPa, elongation more than 15%). Alloy and composite fabrication have proven to be excellent ways to improve the mechanical performance of Zn. Therefore, their alloys and composites have emerged as an innovative category of biodegradable materials. This paper summarizes the most important recent research results on the mechanical and biological characteristics of biodegradable Zn-based implants for orthopedic applications and the most commonly added components in Zn alloys and composites.

15 May 2019 in Revista de Chimie
Verified
Journal Article
Closed access
Baltatu Madalina SimonaBaltatu Madalina Simona
Baltatu Madalina Simona
CTCatalin Andrei Tugui
Catalin Andrei Tugui
MPManuela Cristina Perju
Manuela Cristina Perju
Marcelin BencheaMarcelin Benchea
Marcelin Benchea
MSMihaela Claudia Spataru
Mihaela Claudia Spataru
Petrica VizureanuPetrica Vizureanu
Petrica Vizureanu
At global level, there is a continuing concern for the research and development of alloys for medical and biomedical applications. Metallic biomaterials are used in various applications of the most important medical fields like orthopedic, dental and cardiovascular. The main metallic biomaterials used in human body are stainless steels, Co-based alloys and Ti-based alloys. Titanium and its alloys are of greater interest in medical applications because they exhibit characteristics required for implant materials, namely, good mechanical properties (less elasticity modulus than stainless steel or CoCr alloys, fatigue strength, high corrosion resistance), high biocompatibility. The aim of this review is to describe and compare the main characteristics (mechanical properties, corrosion resistance and biocompatibility) for latest research of nontoxic Ti alloys biomaterials used for medical field.

17 May 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
Abbas SaberiAbbas Saberi
Abbas Saberi
Baltatu Madalina SimonaBaltatu Madalina Simona
Baltatu Madalina Simona
Petrica VizureanuPetrica Vizureanu
Petrica Vizureanu
Magnesium (Mg) is considered an attractive option for orthopedic applications due to its density and elastic modulus close to the natural bone of the body, as well as biodegradability and good tensile strength. However, it faces serious challenges, including a high degradation rate and, as a result, a loss of mechanical properties during long periods of exposure to the biological environment. Also, among its other weaknesses, it can be mentioned that it does not deal with bacterial biofilms. It has been found that making composites by synergizing its various components can be an efficient way to improve its properties. Among metal oxide nanoparticles, magnesium oxide nanoparticles (MgO NPs) have distinct physicochemical and biological properties, including biocompatibility, biodegradability, high bioactivity, significant antibacterial properties, and good mechanical properties, which make it a good choice as a reinforcement in composites. However, the lack of comprehensive understanding of the effectiveness of Mg NPs as Mg matrix reinforcements in mechanical, corrosion, and biological fields is considered a challenge in their application. While introducing the role of MgO NPs in medical fields, this article summarizes the most important results of recent research on the mechanical, corrosion, and biological performance of Mg/MgO composites.

9 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
Baltatu Madalina SimonaBaltatu Madalina Simona
Baltatu Madalina Simona
Petrica VizureanuPetrica Vizureanu
Petrica Vizureanu
Andrei Victor SanduAndrei Victor Sandu
Andrei Victor Sandu
NSNestor Ruben Florido Suarez
Nestor Ruben Florido Suarez
VSVicentiu Mircea Saceleanu
Vicentiu Mircea Saceleanu
Julia C. Mirza-RoscaJulia C. Mirza-Rosca
Julia C. Mirza-Rosca
Titanium alloys are used in medical devices due to their mechanical properties, but also for their corrosion resistance. The natural passivation of titanium-based biomaterials, on the surface of which a dense and coherent film of nanometric thickness is formed, composed mainly of TiO2, determines an apparent bioactivity of them. In this paper, the method of obtaining new Ti20MoxSi alloys (x = 0.0, 0.5, 0.75, and 1.0) is presented, their microstructure is analyzed, and their electrochemical responses in Ringer´s solution were systematically investigated by linear polarization, cyclic potential dynamic polarization, and electrochemical impedance spectroscopy (EIS). The alloys corrosion resistance is high, and no evidence of localized breakdown of the passive layer was observed. There is no regularity determined by the composition of the alloys, in terms of corrosion resistance, but it seems that the most resistant is Ti20Mo1.0Si.

25 November 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
Baltatu Madalina SimonaBaltatu Madalina Simona
Baltatu Madalina Simona
Andrei Victor SanduAndrei Victor Sandu
Andrei Victor Sandu
Marcin NabiałekMarcin Nabiałek
Marcin Nabiałek
Petrica VizureanuPetrica Vizureanu
Petrica Vizureanu
Gabriela CiobanuGabriela Ciobanu
Gabriela Ciobanu
Over the last decade, researchers have been concerned with improving metallic biomaterials with proper and suitable properties for the human body. Ti-based alloys are widely used in the medical field for their good mechanical properties, corrosion resistance and biocompatibility. The TiMoZrTa system (TMZT) evidenced adequate mechanical properties, was closer to the human bone, and had a good biocompatibility. In order to highlight the osseointegration of the implants, a layer of hydroxyapatite (HA) was deposited using a biomimetic method, which simulates the natural growth of the bone. The coatings were examined by scanning electron microscopy (SEM), X-ray diffraction (XRD), micro indentation tests and contact angle. The data obtained show that the layer deposited on TiMoZrTa (TMZT) support is hydroxyapatite. Modifying the surface of titanium alloys represents a viable solution for increasing the osseointegration of materials used as implants. The studied coatings demonstrate a positive potential for use as dental and orthopedic implants.

13 September 2019 in Materials
Verified
Journal Article
Open access
PDF file
Andrei Victor SanduAndrei Victor Sandu
Andrei Victor Sandu
Baltatu Madalina SimonaBaltatu Madalina Simona
Baltatu Madalina Simona
Marcin NabiałekMarcin Nabiałek
Marcin Nabiałek
ASAdriana Savin
Adriana Savin
Petrica VizureanuPetrica Vizureanu
Petrica Vizureanu
Ti-based alloys are accessible for use in the human body due to their good mechanical properties, corrosion resistance, and biocompatibilities. These main properties of alloys are important criteria for choosing biomedical implants for human bones or for other kinds of applications in general medicine. This paper presents a comparison of four new Ti-based alloys desired to satisfy various requirements for biomedical implants. The materials were prepared with recipes for two new system alloys, TiMoZrTa (TMZT) and TiMoSi (TMS), alloys with nontoxic elements. The presented research contains microstructure images, indentation tests, Vickers hardness, XRD, and corrosion resistance, showing better characteristics than most commercial products used as implants (Young’s modulus closer to the human bone).