1 December 2020 in Physica Medica
Verified
Journal Article
Open access
ASAndreas Schüller
Andreas Schüller
SHSophie Heinrich
Sophie Heinrich
CFCharles Fouillade
Charles Fouillade
ASAnna Subiel
Anna Subiel
LMLudovic De Marzi
Ludovic De Marzi
MVMarie-Catherine Vozenin
Marie-Catherine Vozenin
UHDpulse - Metrology for advanced radiotherapy using particle beams with ultra-high pulse dose rates is a recently started European Joint Research Project with the aim to develop and improve dosimetry standards for FLASH radiotherapy, very high energy electron (VHEE) radiotherapy and laser-driven medical accelerators. This paper gives a short overview about the current state of developments of radiotherapy with FLASH electrons and protons, very high energy electrons as well as laser-driven particles and the related challenges in dosimetry due to the ultra-high dose rate during the short radiation pulses. We summarize the objectives and plans of the UHDpulse project and present the 16 participating partners.

22 April 2022 in Medical Physics
Verified
Journal Article
Open access
FGFaustino Gómez
Faustino Gómez
DGDiego M. Gonzalez‐Castaño
Diego M. Gonzalez‐Castaño
NFNicolás Gómez Fernández
Nicolás Gómez Fernández
JPJuan Pardo‐Montero
Juan Pardo‐Montero
ASAndreas Schüller
Andreas Schüller
JPJose Paz‐Martín
Jose Paz‐Martín
Background: Conventional air ionization chambers (ICs) exhibit ion recombination correction factors that deviate substantially from unity when irradiated with dose per pulse magnitudes higher than those used in conventional radiotherapy. This fact makes these devices unsuitable for the dosimetric characterization of beams in ultra‐high dose per pulse as used for FLASH radiotherapy.Purpose: We present the design, development, and characterization of an ultra‐thin parallel plate IC that can be used in ultra‐high dose rate (UHDR) deliveries with minimal recombination.Methods: The charge collection efficiency (CCE) of parallel plate ICs was modeled through a numerical solution of the coupled differential equations governing the transport of charged carriers produced by ionizing radiation. It was used to find out the optimal parameters for the purpose of designing an IC capable of exhibiting a linear response with dose (deviation less than 1%) up to 10 Gy per pulse at 4 s pulse duration. As a proof of concept, two vented parallel plate IC prototypes have been built and tested in different ultra‐high pulse dose rate electron beams.Results: It has been found that by reducing the distance between electrodes to a value of 0.25 mm it is possible to extend the dose rate operating range of parallel plate ICs to ultra‐high dose per pulse range, at standard voltage of clinical grade electrometers, well into several Gy per pulse. The two IC prototypes exhibit behavior as predicted by the numerical simulation. One of the so‐called ultra‐thin parallel plate ionization chamber (UTIC) prototypes was able to measure up to 10 Gy per pulse, 4 s pulse duration, operated at 300 V with no significant deviation from linearity within the uncertainties (ElectronFlash Linac, SIT). The other prototype was tested up to 5.4 Gy per pulse, 2.5 s pulse duration, operated at 250 V with CCE higher than 98.6% (Metrological Electron Accelerator Facility, MELAF at Physikalisch‐Technische Bundesanstalt, PTB).Conclusions: This work demonstrates the ability to extend the dose rate operating range of ICs to ultra‐high dose per pulse range by reducing the spacing between electrodes. The results show that UTICs are suitable for measurement in UHDR electron beams.

20 January 2010 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
FGFaustino Gómez
Faustino Gómez
AIA Iglesias
A Iglesias
FDF Sánchez Doblado
F Sánchez Doblado
This work focuses on neutron monitoring at clinical linac facilities during high-energy modality radiotherapy treatments. Active in-room measurement of neutron fluence is a complex problem due to the pulsed nature of the fluence and the presence of high photon background, and only passive methods have been considered reliable until now. In this paper we present a new active method to perform real-time measurement of neutron production around a medical linac. The device readout is being investigated as an estimate of patient neutron dose exposure on each radiotherapy session. The new instrument was developed based on neutron interaction effects in microelectronic memory devices, in particular using neutron-sensitive SRAM devices. This paper is devoted to the description of the instrument and measurement techniques, presenting the results obtained together with their comparison and discussion. Measurements were performed in several standard clinical linac facilities, showing high reliability, being insensitive to the photon fluence and EM pulse present inside the radiotherapy room, and having detector readout statistical relative uncertainties of about 2% on measurement of neutron fluence produced by 1000 monitor units irradiation runs.

31 March 2005 in Physics in Medicine & Biology
Verified
Journal Article
Open access
JPJuan Pardo-Montero
Juan Pardo-Montero
LFL Franco
L Franco
FGFaustino Gómez
Faustino Gómez
AIA Iglesias
A Iglesias
APA Pazos
A Pazos
JSJ Sendón
J Sendón
A liquid isooctane (C(8)H(18)) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, each of them with an area of 1.7 mm x 1.7 mm and a gap of 0.5 mm. The small pixel size makes the detector ideal for high gradient beam profiles such as those present in intensity modulated radiation therapy (IMRT) and radiosurgery. As the read-out electronics we use the X-ray Data Acquisition System with the Xchip developed by the CCLRC. Studies concerning the collection efficiency dependence on the polarization voltage and on the dose rate have been made in order to optimize the device operation. In the first tests, we have studied dose rate and energy dependences. Dose rate dependence was found to be lower than 2.1% up to 5 Gy min(-1), and energy dependence lower than 2.5% up to 20 cm depth in solid water. Output factors and penumbras for several rectangular fields have been measured with the linear array and were compared with the results obtained with a 0.125 cm(3) air ionization chamber and radiographic film, respectively. Finally, we have acquired profiles for an IMRT field and for a virtual wedge. These profiles have also been compared with radiographic film measurements. All the comparisons show a good correspondence. The device has proved its capability to verify on-line therapy beams with good spatial resolution and signal-to-noise ratio.

28 November 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
CGConsuelo Guardiola
Consuelo Guardiola
CFCeleste Fleta
Celeste Fleta
DQDavid Quirion
David Quirion
GPGiulio Pellegrini
Giulio Pellegrini
FGFaustino Gómez
Faustino Gómez
The present overview describes the evolution of new microdosimeters developed in the National Microelectronics Center in Spain (IMB-CNM, CSIC), ranging from the first ultra-thin 3D diodes (U3DTHINs) to the advanced 3D-cylindrical microdetectors, which have been developed over the last 10 years. In this work, we summarize the design, main manufacture processes, and electrical characterization of these devices. These sensors were specifically customized for use in particle therapy and overcame some of the technological challenges in this domain, namely the low noise capability, well-defined sensitive volume, high spatial resolution, and pile-up robustness. Likewise, both architectures reduce the loss of charge carriers due to trapping effects, the charge collection time, and the voltage required for full depletion compared to planar silicon detectors. In particular, a 3D‒cylindrical architecture with electrodes inserted into the silicon bulk and with a very well‒delimited sensitive volume (SV) mimicked a cell array with shapes and sizes similar to those of mammalian cells for the first time. Experimental tests of the carbon beamlines at the Grand Accélérateur National d’Lourds (GANIL, France) and Centro Nazionale Adroterapia Oncologica (CNAO, Italy) showed the feasibility of the U3DTHINs in hadron therapy beams and the good performance of the 3D‒cylindrical microdetectors for assessing linear energy distributions of clinical beams, with clinical fluence rates of 5 × 107 s−1cm−2 without saturation. The dose-averaged lineal energies showed a generally good agreement with Monte Carlo simulations. The results indicated that these devices can be used to characterize the microdosimetric properties in hadron therapy, even though the charge collection efficiency (CCE) and electronic noise may pose limitations on their performance, which is studied and discussed herein. In the last 3D‒cylindrical microdetector generation, we considerably improved the CCE due to the microfabrication enhancements, which have led to shallower and steeper dopant profiles. We also summarize the successive microdosimetric characterizations performed with both devices in proton and carbon beamlines.

28 October 2022 in Physica Medica
Verified
Journal Article
Open access
JPJose Paz-Martín
Jose Paz-Martín
ASAndreas Schüller
Andreas Schüller
ABAlexandra Bourgouin
Alexandra Bourgouin
DGDiego M. González-Castaño
Diego M. González-Castaño
NGNicolás Gómez-Fernández
Nicolás Gómez-Fernández
FGFaustino Gómez
Faustino Gómez
Air-vented ionization chambers have been the secondary standard for radiation dosimetry since the origins of radiation metrology. However, the feasibility of their use in ultra-high dose rate pulsed beams has been a matter of discussion, as large losses are caused by ion recombinations and no suitable theoretical model is available for their correction. The theories developed by Boag and his contemporaries since the 1950s, which have provided the standard ion recombination correction factor in clinical dosimetry, do not provide an accurate description when used under the limit conditions of ultra-high dose rates (UHDRs). Moreover, the high-ion recombination effects of ionization chambers under extreme dose-rate applications are an obstacle to the development of adequate dosimetry standards. In this article, the charge carrier transport equations within a parallel plate ionization chamber (PPIC) have been solved numerically with a double aim. First, this numerical model provides a more accurate tool that can be used to evaluate ion recombination correction for established PPICs in pulsed ultra-high dose rate regimes. Second, studying the chamber behavior in detail allow as to explore the limits of new chamber designs in order to improve their performance under UHDRs. The model presented here has been tested by measuring the instantaneous current of one unit of a Roos chamber (i.e., the time-resolved current during and after the irradiation pulse under UHDR conditions) and comparing these results with the absolute value of the simulated current. The experimental data show consistent agreement with the results obtained using the numerical model. The experimental instantaneous current reveals effects such as the variation of the free electron fraction with the dose per pulse that are supported by the numerical model but cannot be explained in the framework of Boag's theory. Numerical solutions of the charge carrier released and transport in ionization chambers are able to estimate the effects observed when PPICs are irradiated with ultra-high dose rate beams and to provide new insight into processes related to recombination losses at UHDRs. These models can be reliably extended to include regions where current analytical solutions are not valid. An agreement of better than 5 % between the experimental and simulated effective free electron fraction is found. We were able to reproduce the instantaneous current from a Roos chamber. The discrepancies observed between the experimental data and the numerical simulations can be attributed to the uncertainty about the transport parameters involved in the calculation.