Francisco Sánchez-Doblado

Francisco Sánchez-Doblado

Auto-generated profile, based on publicly available information

Francisco Sánchez-Doblado

Servicio de Radiofisica, Hospital Universitario Virgen Macarena, Sevilla, Spain

Research Focus & Metrics

Academic Career Length

42Years (1985-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2003 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
FNF S Nchez-Doblado
F S Nchez-Doblado
PAP Andreo
P Andreo
RCR Capote
R Capote
APAntonio Leal Plaza
Antonio Leal Plaza
MPM Perucha
M Perucha
ECE Carrasco
E Carrasco
Absolute dosimetry with ionization chambers of the narrow photon fields used in stereotactic techniques and IMRT beamlets is constrained by lack of electron equilibrium in the radiation field. It is questionable that stopping-power ratio in dosimetry protocols, obtained for broad photon beams and quasi-electron equilibrium conditions, can be used in the dosimetry of narrow fields while keeping the uncertainty at the same level as for the broad beams used in accelerator calibrations. Monte Carlo simulations have been performed for two 6 MV clinical accelerators (Elekta SL-18 and Siemens Mevatron Primus), equipped with radiosurgery applicators and MLC. Narrow circular and Z-shaped on-axis and off-axis fields, as well as broad IMRT configured beams, have been simulated together with reference 10 x 10 cm2 beams. Phase-space data have been used to generate 3D dose distributions which have been compared satisfactorily with experimental profiles (ion chamber, diodes and film). Photon and electron spectra at various depths in water have been calculated, followed by Spencer-Attix (delta = 10 keV) stopping-power ratio calculations which have been compared to those used in the IAEA TRS-398 code of practice. For water/air and PMMA/air stopping-power ratios, agreements within 0.1% have been obtained for the 10 x 10 cm2 fields. For radiosurgery applicators and narrow MLC beams, the calculated s(w,air) values agree with the reference within +/-0.3%, well within the estimated standard uncertainty of the reference stopping-power ratios (0.5%). Ionization chamber dosimetry of narrow beams at the photon qualities used in this work (6 MV) can therefore be based on stopping-power ratios data in dosimetry protocols. For a modulated 6 MV broad beam used in clinical IMRT, s(w,air) agrees within 0.1% with the value for 10 x 10 cm2, confirming that at low energies IMRT absolute dosimetry can also be based on data for open reference fields. At higher energies (24 MV) the difference in s(w,air) was up to 1.1%, indicating that the use of protocol data for narrow beams in such cases is less accurate than at low energies, and detailed calculations of the dosimetry parameters involved should be performed if similar accuracy to that of 6 MV is sought.

19 August 2004 in Medical Physics
Verified
Journal Article
Closed access
RCRoberto Capote
Roberto Capote
FSFrancisco Sánchez‐Doblado
Francisco Sánchez‐Doblado
APAntonio Leal Plaza
Antonio Leal Plaza
JLJuan Ignacio Lagares
Juan Ignacio Lagares
RARafael Arráns
Rafael Arráns
GHGünther H. Hartmann
Günther H. Hartmann

10 May 2007 in Physica Medica
Verified
Journal Article
Closed access
PDF file
FSF. Sánchez-Doblado
F. Sánchez-Doblado
GHG.H. Hartmann
G.H. Hartmann
JPJ. Pena
J. Pena
JRJ.V. Roselló
J.V. Roselló
GRG. Russiello
G. Russiello
DGD.M. Gonzalez-Castaño
D.M. Gonzalez-Castaño

1 May 2003 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
APAntonio Leal Plaza
Antonio Leal Plaza
FSFrancisco Sánchez-Doblado
Francisco Sánchez-Doblado
RARafael Arráns
Rafael Arráns
JRJoan Roselló
Joan Roselló
EPEster Carrasco Pavón
Ester Carrasco Pavón
JLJuan Ignacio Lagares
Juan Ignacio Lagares

13 September 2012 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
FSF Sánchez-Doblado
F Sánchez-Doblado
CDC Domingo
C Domingo
FGF Gómez
F Gómez
BSB Sánchez-Nieto
B Sánchez-Nieto
JMJ L Muñiz
J L Muñiz
FFF Fernández
F Fernández
Neutron peripheral contamination in patients undergoing high-energy photon radiotherapy is considered as a risk factor for secondary cancer induction. Organ-specific neutron-equivalent dose estimation is therefore essential for a reasonable assessment of these associated risks. This work aimed to develop a method to estimate neutron-equivalent doses in multiple organs of radiotherapy patients. The method involved the convolution, at 16 reference points in an anthropomorphic phantom, of the normalized Monte Carlo neutron fluence energy spectra with the kerma and energy-dependent radiation weighting factor. This was then scaled with the total neutron fluence measured with passive detectors, at the same reference points, in order to obtain the equivalent doses in organs. The latter were correlated with the readings of a neutron digital detector located inside the treatment room during phantom irradiation. This digital detector, designed and developed by our group, integrates the thermal neutron fluence. The correlation model, applied to the digital detector readings during patient irradiation, enables the online estimation of neutron-equivalent doses in organs. The model takes into account the specific irradiation site, the field parameters (energy, field size, angle incidence, etc) and the installation (linac and bunker geometry). This method, which is suitable for routine clinical use, will help to systematically generate the dosimetric data essential for the improvement of current risk-estimation models.

26 February 2007 in Medical Physics
Verified
Journal Article
Closed access
JPJavier Pena
Javier Pena
DGDiego M. González‐Castaño
Diego M. González‐Castaño
FGFaustino Gómez
Faustino Gómez
FSFrancisco Sánchez‐Doblado
Francisco Sánchez‐Doblado
GHGuenther H. Hartmann
Guenther H. Hartmann