Antonio Leal Plaza

Prof. Dr. Antonio Leal Plaza

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2007 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
BVBarbara Vanderstraeten
Barbara Vanderstraeten
PCPik Wai Chin
Pik Wai Chin
MFMichael Fix
Michael Fix
APAntonio Leal Plaza
Antonio Leal Plaza
GMGrisel Mora
Grisel Mora
HTHubert Thierens
Hubert Thierens
The conversion of computed tomography (CT) numbers into material composition and mass density data influences the accuracy of patient dose calculations in Monte Carlo treatment planning (MCTP). The aim of our work was to develop a CT conversion scheme by performing a stoichiometric CT calibration. Fourteen dosimetrically equivalent tissue subsets (bins), of which ten bone bins, were created. After validating the proposed CT conversion scheme on phantoms, it was compared to a conventional five bin scheme with only one bone bin. This resulted in dose distributions D14and D5for nine clinical patient cases in a European multi-centre study. The observed local relative differences in dose to medium were mostly smaller than 5%. The dose–volume histograms of both targets and organs at risk were comparable, although within bony structures D14was found to be slightly but systematically higher than D5. Converting dose to medium to dose to water (D14to D14watand D5to D5wat) resulted in larger local differences as D5watbecame up to 10% higher than D14wat. In conclusion, multiple bone bins need to be introduced when Monte Carlo (MC) calculations of patient dose distributions are converted to dose to water.

2 July 2003 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
FNF S Nchez-Doblado
F S Nchez-Doblado
PAP Andreo
P Andreo
RCR Capote
R Capote
APAntonio Leal Plaza
Antonio Leal Plaza
MPM Perucha
M Perucha
ECE Carrasco
E Carrasco
Absolute dosimetry with ionization chambers of the narrow photon fields used in stereotactic techniques and IMRT beamlets is constrained by lack of electron equilibrium in the radiation field. It is questionable that stopping-power ratio in dosimetry protocols, obtained for broad photon beams and quasi-electron equilibrium conditions, can be used in the dosimetry of narrow fields while keeping the uncertainty at the same level as for the broad beams used in accelerator calibrations. Monte Carlo simulations have been performed for two 6 MV clinical accelerators (Elekta SL-18 and Siemens Mevatron Primus), equipped with radiosurgery applicators and MLC. Narrow circular and Z-shaped on-axis and off-axis fields, as well as broad IMRT configured beams, have been simulated together with reference 10 x 10 cm2 beams. Phase-space data have been used to generate 3D dose distributions which have been compared satisfactorily with experimental profiles (ion chamber, diodes and film). Photon and electron spectra at various depths in water have been calculated, followed by Spencer-Attix (delta = 10 keV) stopping-power ratio calculations which have been compared to those used in the IAEA TRS-398 code of practice. For water/air and PMMA/air stopping-power ratios, agreements within 0.1% have been obtained for the 10 x 10 cm2 fields. For radiosurgery applicators and narrow MLC beams, the calculated s(w,air) values agree with the reference within +/-0.3%, well within the estimated standard uncertainty of the reference stopping-power ratios (0.5%). Ionization chamber dosimetry of narrow beams at the photon qualities used in this work (6 MV) can therefore be based on stopping-power ratios data in dosimetry protocols. For a modulated 6 MV broad beam used in clinical IMRT, s(w,air) agrees within 0.1% with the value for 10 x 10 cm2, confirming that at low energies IMRT absolute dosimetry can also be based on data for open reference fields. At higher energies (24 MV) the difference in s(w,air) was up to 1.1%, indicating that the use of protocol data for narrow beams in such cases is less accurate than at low energies, and detailed calculations of the dosimetry parameters involved should be performed if similar accuracy to that of 6 MV is sought.

19 August 2004 in Medical Physics
Verified
Journal Article
Closed access
RCRoberto Capote
Roberto Capote
FSFrancisco Sánchez‐Doblado
Francisco Sánchez‐Doblado
APAntonio Leal Plaza
Antonio Leal Plaza
JLJuan Ignacio Lagares
Juan Ignacio Lagares
RARafael Arráns
Rafael Arráns
GHGünther H. Hartmann
Günther H. Hartmann

1 May 2003 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
APAntonio Leal Plaza
Antonio Leal Plaza
FSFrancisco Sánchez-Doblado
Francisco Sánchez-Doblado
RARafael Arráns
Rafael Arráns
JRJoan Roselló
Joan Roselló
EPEster Carrasco Pavón
Ester Carrasco Pavón
JLJuan Ignacio Lagares
Juan Ignacio Lagares

30 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Alessandro StefanoAlessandro Stefano
Alessandro Stefano
APAntonio Leal Plaza
Antonio Leal Plaza
Selene RichiusaSelene Richiusa
Selene Richiusa
PTPhan Trang
Phan Trang
Albert ComelliAlbert Comelli
Albert Comelli
Giorgio RussoGiorgio Russo
Giorgio Russo
Radiomics holds great promise in the field of cancer management. However, the clinical application of radiomics has been hampered by uncertainty about the robustness of the features extracted from the images. Previous studies have reported that radiomics features are sensitive to changes in voxel size resampling and interpolation, image perturbation, or slice thickness. This study aims to observe the variability of positron emission tomography (PET) radiomics features under the impact of co-registration with magnetic resonance imaging (MRI) using the difference percentage coefficient, and the Spearman’s correlation coefficient for three groups of images: (i) original PET, (ii) PET after co-registration with T1-weighted MRI and (iii) PET after co-registration with FLAIR MRI. Specifically, seventeen patients with brain cancers undergoing [11C]-Methionine PET were considered. Successively, PET images were co-registered with MRI sequences and 107 features were extracted for each mentioned group of images. The variability analysis revealed that shape features, first-order features and two subgroups of higher-order features possessed a good robustness, unlike the remaining groups of features, which showed large differences in the difference percentage coefficient. Furthermore, using the Spearman’s correlation coefficient, approximately 40% of the selected features differed from the three mentioned groups of images. This is an important consideration for users conducting radiomics studies with image co-registration constraints to avoid errors in cancer diagnosis, prognosis, and clinical outcome prediction.

3 April 2006 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
FPF C P du Plessis
F C P du Plessis
APAntonio Leal Plaza
Antonio Leal Plaza
SSS Stathakis
S Stathakis
WXW Xiong
W Xiong
CMC-M Ma
C-M Ma
A study is presented that characterizes megavoltage electron beams delivered through an existing double-focused photon multi-leaf collimator (pMLC) using film measurements in a solid water phantom. Machine output stability and linearity were evaluated as well as the effect of source-to-surface distance (SSD) and field size on the penumbra for electron energies between 6 and 18 MeV over an SSD range of 60-100 cm. Penumbra variations as a function of field size, depth of measurement and the influence of the jaws were also studied. Field abutment, field flatness and target coverage for segmented beams were also addressed. The measured field size for electrons transported through the pMLC was the same as that for an x-ray beam up to SSDs of 70 cm. At larger SSD, the lower energy electron fields deviated from the projected field. Penumbra data indicated that 60 cm SSD was the most favourable treatment distance. Backprojection of P(20-80) penumbra data yielded a virtual source position located at 98.9 cm from the surface for 18 MeV electrons. For 6 MeV electrons, the virtual source position was at a distance of 82.6 cm. Penumbra values were smaller for small beam slits and reached a near-constant value for field widths larger than 5 cm. The influence of the jaws had a small effect on the penumbra. The R90 values ranged from 1.4 to 4.8 cm between 6 and 21 MeV as measured at 60 cm SSD for a 9 x 9 cm2 field. Uniformity and penumbra improvement could be demonstrated using weighted abutted fields especially useful for small segments. No detectable electron leakage through the pMLC was observed. Bremsstrahlung measurements taken at 60 cm SSD for a 9 x 9 cm2 field as shaped by the pMLC compared within 1% to bremsstrahlung measurements taken at 100 cm SSD for a 10 x 10 cm2 electron applicator field at 100 cm SSD.