Jose Jesus Broseta

Dr. Jose Jesus Broseta

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in American Journal of Kidney Diseases
Verified
Journal Article
Closed access
PDF file
JBJose Jesus Broseta
Jose Jesus Broseta
DRDiana Rodríguez-Espinosa
Diana Rodríguez-Espinosa
NRNéstor Rodríguez
Néstor Rodríguez
MMMaría del Mar Mosquera
María del Mar Mosquera
MMMaría Ángeles Marcos
María Ángeles Marcos
FMFrancisco Maduell
Francisco Maduell

3 April 2019 in Blood Purification
Verified
Journal Article
Closed access
PDF file
Francisco MaduellFrancisco Maduell
Francisco Maduell
LRLida Rodas
Lida Rodas
JBJose Jesus Broseta
Jose Jesus Broseta
MGMiquel Gomez
Miquel Gomez
MXMarc Xipell
Marc Xipell
NRNaira Rico
Naira Rico
Background: A novel class of membranes, medium cut-off (MCO) membranes, has recently been designed to achieve interesting removal capacities for middle and large middle molecules in hemodialysis (HD) treatments. The few studies published to date have reported contradictory results regarding middle-sized molecules when comparing MCO dialyzers versus dialyzers used in online hemodiafiltration (OL-HDF). Methods: A prospective, single-center study was carried out in 22 patients. Each patient underwent 9 dialysis sessions with routine dialysis parameters, one with an MCO dialyzer in HD and the other 8 with different dialyzers in OL-HDF. The removal ratio (RR) of urea, creatinine, β2-microglobulin, myoglobin, prolactin, α1-microglobulin, α1-acid glycoprotein, and albumin was intraindividually compared. Albumin loss in dialysate was measured. We propose a global removal score ([ureaRR + β2-microglobulinRR + myoglobinRR + prolactinRR + α1-microglobulinRR + α1-acid glycoproteinRR]/6 – albuminRR) as a new tool for measuring dialyzer effectiveness. Results: No significant differences in the RRs of small and middle molecular range molecules were observed between the MCO vs. OL-HDF dialyzers (range 60–80%). Lower RRs were found for α1-microglobulin and α1-acid glycoprotein without significant differences. The albumin RR was < 11% and dialysate albumin loss was < 3.5 g in all situations without significant differences. The global removal score was 54.9 ± 4.8% with the MCO dialyzer without significant differences. Conclusions: Removal of a wide range of molecular weights, calculated with the proposed global removal score, was almost equal with the MCO dialyzer in HD treatment compared with 8 high-flux dialyzers in high-volume OL-HDF without relevant changes in albumin loss. The global removal score could be a new tool to evaluate the effectiveness of dialyzers and/or different treatment modalities.

13 July 2022 in Clinical Kidney Journal
Verified
Journal Article
Open access
PDF file
Francisco MaduellFrancisco Maduell
Francisco Maduell
JBJose Jesus Broseta
Jose Jesus Broseta
DRDiana Rodríguez-Espinosa
Diana Rodríguez-Espinosa
JRJimena del Risco
Jimena del Risco
LRLida María Rodas
Lida María Rodas
NRNayra Rico
Nayra Rico
Background: Recently, several pharmaceutical companies have developed new medium cut-off (MCO) dialyzers for expanded hemodialysis (HDx). This study aimed to compare the safety and efficacy of four MCO dialyzers, against each other and versus high-flux hemodialysis (HD) and post-dilution hemodiafiltration (HDF). Methods: A prospective study was carried out on 23 patients who underwent six dialysis sessions: two sessions with the FX80 Cordiax in HD and HDF, and four HDx sessions with the Phylther 17-SD, Vie-18X, Elisio HX19 and Theranova 400 dialyzers. The reduction ratios (RRs) of urea, creatinine, β2-microglobulin, myoglobin, kappa free immunoglobulin light chain (κFLC), prolactin, α1-microglobulin, α1-acid glycoprotein, lambda (λFLC) and albumin were compared. Dialysate albumin loss was also measured. Results: The differences in efficacy between the evaluated dialyzers were minimal in small molecules and even up to the size of β2-microglobulin. The main differences were found between myoglobin, κFLC, prolactin, α1-microglobulin and λFLC RRs, in which all four MCO dialyzers, with similar efficacy, were clearly superior to HD and slightly inferior to HDF treatment. Albumin losses in the dialysate with HD dialyzers were <1 g and between 1.5 and 2.5 g in HDx and HDF. The global removal score values were similar in all four HDx treatments, and again significantly higher than those with HD. Conclusions: The results of the four MCO dialyzers evaluated in this study showed good efficiency, with no significant performance differences between them while being completely safe in terms of albumin loss. Likewise, the study confirms the superiority of HDx over high-flux HD with an efficacy close to that of post-dilution HDF.

30 April 2019 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
Francisco MaduellFrancisco Maduell
Francisco Maduell
LRLida Rodas
Lida Rodas
JBJose Jesus Broseta
Jose Jesus Broseta
MGMiguel Gómez
Miguel Gómez
MXMarc Xipell
Marc Xipell
NRNayra Rico
Nayra Rico

3 October 2019 in Therapeutic Apheresis and Dialysis
Verified
Journal Article
Closed access
PDF file
Francisco MaduellFrancisco Maduell
Francisco Maduell
JBJose Jesus Broseta
Jose Jesus Broseta
LRLida Rodas
Lida Rodas
EMEnrique Montagud‐Marrahi
Enrique Montagud‐Marrahi
DRDiana Rodríguez-Espinosa
Diana Rodríguez-Espinosa
NRNayra Rico
Nayra Rico

30 September 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JLJulia Hernández Lluesa
Julia Hernández Lluesa
LRLuis Carlos Lopez Romero
Luis Carlos Lopez Romero
JBJose Jesus Broseta
Jose Jesus Broseta
MMMarta Roca Marugán
Marta Roca Marugán
Iris Viejo BoyanoIris Viejo Boyano
Iris Viejo Boyano
JJJulio Hernández Jaras
Julio Hernández Jaras
Patients on peritoneal dialysis (PD) have an increased risk of cardiovascular disease (CVD) and an atherogenic lipid profile generated by exposure to high glucose dialysis solutions. In the general population, the reduction of classic lipids biomarkers is associated with improved clinical outcomes; however, the same results have not been seen in PD population, a lack of data this study aims to fulfill. Single-center prospective observational study of a cohort of CKD patients who started renal replacement therapy with continuous ambulatory peritoneal dialysis. The differences in the lipid profile and analytical variables before and 6 months after the start of peritoneal dialysis were analyzed. Samples were analyzed on an Ultra-Performance Liquid Chromatography system. Thirty-nine patients were enrolled in this study. Their mean age was 57.9 ± 16.3 years. A total of 157 endogenous lipid species of 11 lipid subclasses were identified. There were significant increases in total free fatty acids (p < 0.05), diacylglycerides (p < 0.01), triacylglycerides, (p < 0.01), phosphatidylcholines (p < 0.01), phosphatidylethanolamines (p < 0.01), ceramides (p < 0.01), sphingomyelins (p < 0.01), and cholesterol esters (p < 0.01) from baseline to 6 months. However, there were no differences in the classical lipid markers, neither lysophosphatidylcholines, monoacylglycerides, and sphingosine levels. 6 months after the start of the technique, PD patients present changes in the lipidomic profile beyond the classic markers of dyslipidemia.