Marc Xipell

Dr. Marc Xipell

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2019 in Blood Purification
Verified
Journal Article
Closed access
PDF file
Francisco MaduellFrancisco Maduell
Francisco Maduell
LRLida Rodas
Lida Rodas
JBJose Jesus Broseta
Jose Jesus Broseta
MGMiquel Gomez
Miquel Gomez
MXMarc Xipell
Marc Xipell
NRNaira Rico
Naira Rico
Background: A novel class of membranes, medium cut-off (MCO) membranes, has recently been designed to achieve interesting removal capacities for middle and large middle molecules in hemodialysis (HD) treatments. The few studies published to date have reported contradictory results regarding middle-sized molecules when comparing MCO dialyzers versus dialyzers used in online hemodiafiltration (OL-HDF). Methods: A prospective, single-center study was carried out in 22 patients. Each patient underwent 9 dialysis sessions with routine dialysis parameters, one with an MCO dialyzer in HD and the other 8 with different dialyzers in OL-HDF. The removal ratio (RR) of urea, creatinine, β2-microglobulin, myoglobin, prolactin, α1-microglobulin, α1-acid glycoprotein, and albumin was intraindividually compared. Albumin loss in dialysate was measured. We propose a global removal score ([ureaRR + β2-microglobulinRR + myoglobinRR + prolactinRR + α1-microglobulinRR + α1-acid glycoproteinRR]/6 – albuminRR) as a new tool for measuring dialyzer effectiveness. Results: No significant differences in the RRs of small and middle molecular range molecules were observed between the MCO vs. OL-HDF dialyzers (range 60–80%). Lower RRs were found for α1-microglobulin and α1-acid glycoprotein without significant differences. The albumin RR was < 11% and dialysate albumin loss was < 3.5 g in all situations without significant differences. The global removal score was 54.9 ± 4.8% with the MCO dialyzer without significant differences. Conclusions: Removal of a wide range of molecular weights, calculated with the proposed global removal score, was almost equal with the MCO dialyzer in HD treatment compared with 8 high-flux dialyzers in high-volume OL-HDF without relevant changes in albumin loss. The global removal score could be a new tool to evaluate the effectiveness of dialyzers and/or different treatment modalities.

1 May 2017 in Laboratory Investigation
Verified
Journal Article
Closed access
BGBlanca Gonzalez-Farre
Blanca Gonzalez-Farre
DMDaniel Martínez
Daniel Martínez
MLMonica Lopez-Guerra
Monica Lopez-Guerra
MXMarc Xipell
Marc Xipell
EMEster Monclus
Ester Monclus
AMAntonio Martinez
Antonio Martinez

26 May 2021 in Transplant Infectious Disease
Verified
Journal Article
Closed access
PDF file
CACarolt Arana Aliaga
Carolt Arana Aliaga
RRRafael E. Cuevas Ramírez
Rafael E. Cuevas Ramírez
MXMarc Xipell
Marc Xipell
JCJoaquim Casals
Joaquim Casals
ACAsunción Moreno Camacho
Asunción Moreno Camacho
NENúria Esforzado
Núria Esforzado

30 April 2019 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
Francisco MaduellFrancisco Maduell
Francisco Maduell
LRLida Rodas
Lida Rodas
JBJose Jesus Broseta
Jose Jesus Broseta
MGMiguel Gómez
Miguel Gómez
MXMarc Xipell
Marc Xipell
NRNayra Rico
Nayra Rico

1 February 2017 in International Journal of Antimicrobial Agents
Verified
Journal Article
Closed access
MXMarc Xipell
Marc Xipell
MBMarta Bodro
Marta Bodro
FMFrancesc David Marco
Francesc David Marco
RLRicardo A. Losno
Ricardo A. Losno
CCCelia Cardozo
Celia Cardozo
ASAlex Soriano
Alex Soriano

31 March 2020 in BMC Nephrology
Verified
Journal Article
Open access
PDF file
AAAlícia Molina Andújar
Alícia Molina Andújar
PRPau Robles
Pau Robles
MLM. Teresa Cibeira López
M. Teresa Cibeira López
EMEnrique Montagud-Marrahi
Enrique Montagud-Marrahi
EGElena Guillen Guillen-Olmos
Elena Guillen Guillen-Olmos
LQLuis F. Quintana
Luis F. Quintana
Background: Monoclonal serum free light chains (sFLC) are a well-known cause of renal impairment (RI) in patients with multiple myeloma (MM). As an indicator of monoclonality, sFLC ratio has acquired a key role in the diagnosis and monitorization of the disease. However, its interpretation is altered in patients with chronic kidney disease (CKD). This study aims to evaluate the modification of the sFLC ratio reference range in patients with CKD, and propose an optimal range for patients with CKD. Methods: Serum FLC κ/λ ratio and estimated glomerular filtration rate (eGFR) were retrospectively analyzed in 113 control patients (without hematologic disease), 63 patients with MM in complete remission and 347 patients with active MM. The three groups included patients with CKD (eGFR < 90). Results: In the group of patients without active MM (n = 176), the sFLC ratio increased at different stages of CKD without pathological significance, with an increase in the number of false positives specially when eGFR is ≤55 ml/min. An optimal range was established for patients with eGFR ≤55 ml/min/1.73 m2: 0.82–3,6 with maximum sensitivity + specificity for that group with an improvement in the Area under the curve (AUC), 0.91 (0.84–0.97) compared with the current ranges proposed by Katzmann and Hutchinson. Conclusions: This study confirms the influence of eGFR on the interpretation of the sFLC ratio, showing a decreasing specificity in progressive CKD stages when using the reference sFLC range (Katzmann), especially in patients with eFGR ≤55. According to our results, we suggest a modified optimal range (0.82–3,6) for eGFR ≤55 ml/min/1.73 m2. It is necessary to validate this modified range in larger and prospective studies.