OBJECTIVES: The intracochlear electrocochleography (ECoG) could be recorded directly from the cochlear implant (CI) electrode in CI recipients with residual hearing. The primary objective of this study is to identify the most sensitive frequency to record cochlear microphonics (CM) in CI users with a wide degree of hearing abilities and deep electrode insertion. The secondary objective is to identify the optimum location within the cochlea to record intracochlear potentials. MATERIALS and METHODS: CMs were recorded from the CI electrodes in eight females and eight males implanted with CIs Pulsar, Concerto, or Sonata, Med-El Corp. RESULTS: Among the tone pips of various frequencies, 1k or 500 Hz were the most sensitive for CI users. The most sensitive place in the cochlea to record the CM potentials depended on the tone frequency used. The deeper into the cochlea the mean maximum CM peak-to-peak amplitude was measured, the lower the stimulating tone frequency was. CONCLUSION: The most optimal recording parameters identified for intracochlear CM recording can be useful for intraoperative and postoperative monitoring of cochlear health in CI users with residual hearing. Cite this article as: Lorens A, Walkowiak A, Polak M, Kowalczuk A, Furmanek M, Skarzynski H, et al. Cochlear Microphonics in Hearing Preservation Cochlear Implantees. J Int Adv Otol 2019; 15(3): 345-51.
1 December 2018 in European Annals of Otorhinolaryngology, Head and Neck Diseases
To date, objective measurements and psychophysical experiments have been used to measure frequency dependent basilar membrane (BM) delays in humans; however, in vivo measurements have not been made. This study aimed to measure BM delays by performing intracochlear electrocochleography in cochlear implant recipients. Sixteen subjects with various degrees of hearing abilities were selected. Postoperative Computer Tomography was performed to determine electrode locations. Electrical potentials in response to acoustic tone pips at 0.25, 0.5, 1, 2, and 4 kHz and clicks were recorded with electrodes at the frequency specific region. The electrode array was inserted up to the characteristic cochlear frequency region of 250 Hz for 6 subjects. Furthermore, the array was inserted in the region of 500 Hz for 15 subjects, and 1, 2, and 4 kHz were reached in all subjects. Intracochlear electrocochleography for each frequency-specific tone pip and clicks showed detectable responses in all subjects. The latencies differed among the cochlear location and the cochlear microphonic (CM) onset latency increased with decreasing frequency and were consistent with click derived band technique. Accordingly, BM delays in humans could be derived. The BM delays increased systematically along the cochlea from basal to apical end and were in accordance with Ruggero and Temchin, 2007.
(1) Background: Current indications for cochlear implants (CIs) have expanded to include patients with appreciable low-frequency hearing. However, longitudinal results indicate that only one-third of these recipients retain full hearing preservation. In another words, the remaining two-thirds lose this facility either partially or fully. This points to the need to better understand the impact of cochlear implantation on cochlear integrity. Intracochlear electrocochleography (ECochG) involves the recording of electrical potentials generated in the inner ear in response to acoustic stimuli, and previous studies have shown that these potentials give an indication of residual inner ear function. Aim of the research: The aim is to monitor intracochlear ECochG during CI surgery and gain a better understanding of how the implant impacted inner ear function. A newly developed SPL Chirp was used for stimulation. (2) Methods: Intracochlear ECochG signals were measured in a subject with residual preoperative low-frequency hearing, while an electrode array was introduced into the cochlea and was continued until the round window was sealed. Afterwards, surgical events were reviewed with the surgeon; preoperative and postoperative radiological data and hearing thresholds were also evaluated. (3) Conclusions: Real-time intraoperative monitoring, with multifrequency evaluation and video recording, has the potential to allow surgeons and audiologists to continuously assess cochlear function. ECochG monitoring may be a useful tool during cochlear implantation to gain frequency-specific information on the status of the patient’s hearing, assisting surgeons to lower hearing trauma during the operation.
Background: In this study, a method to estimate number of electrodes in the acoustic region of Electric Acoustic Stimulation (EAS) subjects was proposed. Aims/Objectives: To develop and validate an anatomy-based method for EAS subjects to estimate the number of electrodes within the acoustic region. Material and methods: The postoperative CTs of adults with various degree of hearing implanted with lateral wall electrodes with mean insertion depth of 23.9 mm (18.0-28.2 mm) and mean insertion angle of 505 degrees (355-695 degrees) were evaluated. Results: The difference between the estimated and measured angle varied between -18 and 25 degrees, with a mean of 0.9 degrees. For the insertion angle of 230 degrees and higher, the maximum difference was 24 degrees. Taking this uncertainty into account, all electrodes in the acoustic region were predicted correctly.