The objective of this study is to investigate the mechanical properties and the composite action of circular concrete-filled steel tube (CFST) columns subjected to compression-torsion load using finite element model analysis. Load–strain (T–γ) curves, normal stress, shear stress, and the composite action between the steel tubes and the interior concrete were analyzed based on the verified 3D finite element models. The results indicate that with the increase of axial force, the maximum shear stress at the core concrete increased significantly, and the maximum shear stress of the steel tubes gradually decreased. Meanwhile, the torsional bearing capacity of the column increased at first and then decreased. The torque share in the columns changed from the tube-sharing domain to the concrete-sharing domain, while the axial force of the steel tube remained unchanged. Practical design equations for the torsional capacity of axially loaded circular CFST columns were proposed based on the parametric analysis. The accuracy and validity of the proposed equations were verified against the collected experimental results.
The objective of this study was to investigate the composite behavior of rectangular concrete-filled cold-formed steel (CFS) tubular stub columns under axial compression. A fine finite 3D solid element model of rectangular concrete-filled cold-formed steel tubular stub column was established by ABAQUS, which utilized a constitutive model of cold-formed steel considering the cold-forming effect and a triaxial plastic-damage constitutive model of the infilled concrete. Good agreement was achieved and the average discrepancy between the experimental and FE results was less than 5%. Based on the verified models, a further parametric analysis was carried out to reveal the influence of various factors on the strength and behavior of the concrete-filled rectangular cold-formed steel tubular stub columns. The factors included constitutive models adopted for cold-formed steel, length over width ratio of the rectangular section, wall-thickness and width, and concrete strength and yield strength of the cold-formed steel. A total of 144 FE models were analyzed. The stress nephogram was reasonably simplified in accordance with the limit state and a theoretical formula considering confinement coefficient was proposed to estimate the ultimate bearing capacity of concrete-filled rectangular cold-formed steel tubular stub columns using the superposition method. The calculated results showed satisfactory agreement with both the experimental and FE results, which proved the validity and accuracy of the formula proposed in this paper. In the proposed formula, the confinement coefficient of square concrete-filled cold-formed steel tubular stub columns is larger than that of hot-rolled steel counterparts but smaller than that of the stainless steel counterparts.
Existing experimental research on bond properties of the interface between Carbon Fiber Reinforced Polymer (CFRP) and damaged concrete is limited, although CFRP strengthening technology has been widely used for corroded reinforced concrete structures. This work investigated the bond behavior of CFRP to the corrosion-cracked concrete interface, in which three factors were considered for experimentation, including corrosion degree, concrete strength and concrete cover thickness. The tests were conducted by developing a self-balancing double shear lap test device. In addition, a corrosion scene was provided simultaneously to simulate the external corrosion environment. The results showed that three peeling modes of CFRP sheets were observed with respect to corrosion degrees of the steel bars. The effects of the three factors on the stripping bearing capacity and effective bond length of CFRP sheets were discussed by systematic parametric analysis. Finally, a nonlinear degenerate law of CFRP-to-concrete interface considering the corrosion degree was improved and verified in this study.
The application of recycled concrete in building structures can not only effectively reduce the generation of construction waste and reduce the excessive dependence on natural aggregates but can also promote the sustainable use of resources and meet the national “double carbon” strategic requirements. This study investigates the effect of the recycled aggregate replacement ratio on the seismic performance of concrete-filled steel tube column–composite beam frames. Five finite element models were developed, considering varying recycled aggregate replacement ratios and the presence or absence of column-end stirrup-confined reinforcement. Dynamic response analyses were conducted. The results reveal that replacing natural aggregates with recycled aggregates reduces the stiffness of concrete-filled steel tube columns by weakening the core concrete, negatively impacting seismic performance and increasing structural stiffness damage. Column-end stirrup-confined reinforcement reduces interface slip between the core concrete and the steel tube by directly restraining the core concrete, thereby enhancing the bending stiffness of the concrete-filled steel tube column and improving the seismic performance of the structure. The seismic performance of recycled concrete frames with column-end stirrup-confined reinforcement is superior to that of conventional concrete frames, demonstrating that column-end reinforcement can effectively mitigate the adverse effects of recycled aggregate replacement on the structure’s seismic performance.