Shu-Feng Lin

Prof. Dr. Shu-Feng Lin


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2024 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
LRLu Rong
Lu Rong
SZShi-Hang Zhang
Shi-Hang Zhang
MYMeng-Fan Yin
Meng-Fan Yin
DWDayong Wang
Dayong Wang
JZJie Zhao
Jie Zhao
SLShu-Feng Lin
Shu-Feng Lin

11 January 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DMDuoxuabn Ma
Duoxuabn Ma
JZJie Zhao
Jie Zhao
DWDayong Wang
Dayong Wang
HLHao Lin
Hao Lin
LRLu Rong
Lu Rong
SLShu-Feng Lin
Shu-Feng Lin
For decades, terahertz (THz) microscopic imaging has been limited by the resolution of the system due to the larger wavelength, the power of the source, and the equivalent noise power of the detector, so a lot of research has focused on single-point scanning imaging. With the development of hardware, full-field THz imaging based on high-power continuous-wave THz sources have been developed such as the direct intensity imaging method and lensless coherent imaging. In particular, the THz direct intensity imaging method requires no complicated computational reconstruction, while the high resolution, as a key issue, still needs to be improved. In this paper, the rotating coherent scattering microscopy was applied to THz imaging for the first time. Here, we designed and fabricated a hemisphere lens with high-resistance silicon. The tilted hemisphere lens transformed the incident divergent beam into a plane wave, and the total internal reflection occurred in the planar surface within the hemispherical lens, and generated evanescent waves in the rare medium. At the same time, the sample was placed very close to the plane of the hemispherical lens, so that the sample was illuminated by the evanescent waves. The scattered waves carried high frequency information to the far field, and thus through an objective, the super-resolution imaging was achieved along a single direction. Then, the hemispherical lens was rotated to obtain coherent scattering microscopic images under different evanescent wave illumination angles. Finally, the full-field super-resolution imaging results were obtained through incoherent superposition.

25 November 2024 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
RNRan Ning
Ran Ning
DWDayong Wang
Dayong Wang
YZYuzhe Zhang
Yuzhe Zhang
LRLu Rong
Lu Rong
YZYushi Zheng
Yushi Zheng
MWMin Wan
Min Wan

4 October 2022 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
XJXiaoyu Jin
Xiaoyu Jin
DWDayong Wang
Dayong Wang
JZJie Zhao
Jie Zhao
LRLu Rong
Lu Rong
YWYunxin Wang
Yunxin Wang
SLShu-Feng Lin
Shu-Feng Lin

26 October 2020 in Journal of Clinical Pharmacy and Therapeutics
Verified
Journal Article
Open access
PDF file
SLShuqing Lin
Shuqing Lin
XHXinze He
Xinze He
GZGuiliang Zhai
Guiliang Zhai
CWChenggang Wang
Chenggang Wang
HXHuiping Xue
Huiping Xue
SLShu-Feng Lin
Shu-Feng Lin
What is known and Objective This study aimed to explore the effect of sulfotanshinone sodium injection combined with tirofiban on vascular endothelial function and indicators of plaque stability in elderly patients with acute coronary syndrome (ACS). Methods We designed a prospective study and enrolled 169 patients with ACS who were admitted to our hospital as subjects. Patients treated with sulfotanshinone sodium injection combined with tirofiban (n = 99) were allocated to the research group (RG), and the remaining patients treated with tirofiban alone were allocated to the control group (n = 70; CG). The two groups were compared in terms of treatment efficacy, adverse reactions, vascular endothelial function, changes in plaque stability indicator levels, prognosis, recurrence rate, and quality of life after the treatment. Results and discussion Treatment response rate, SOD and ET‐1 levels, and quality‐of‐life score were markedly lower in RG than in CG (all P < .05). The incidence of adverse reactions; levels of CD63p, CD62p and GP IIb/IIIa; changes in plaque stability indicator levels; and recurrence rate were markedly higher in RG than in CG (all P < .05). There was no significant difference in 3‐year survival rate between the two groups (P > .05). What is new and Conclusion Compared with tirofiban alone, sulfotanshinone sodium injection combined with tirofiban had superior efficacy and safety in the treatment of ACS. It can effectively reduce recurrence rate and improve quality of life in ACS, making it a strong candidate for popular clinical application.

24 February 2024 in Photonics
Verified
Journal Article
Open access
PDF file
CZChenyu Zhao
Chenyu Zhao
DWDayong Wang
Dayong Wang
SLShu-Feng Lin
Shu-Feng Lin
JZJie Zhao
Jie Zhao
YWYunxin Wang
Yunxin Wang
LRLu Rong
Lu Rong
The modulation of a terahertz (THz) wave on amplitude, phase and polarization is important for the application of THz technology, especially in the field of imaging, and is one of the current research hotspots. Silicon-based, optically excited THz modulator is a wavefront modulation technique with a simple, compact and reconfigurable optical path. It can realize the dynamic modulation of THz wavefronts by only changing the projected two-dimensional pattern, but it still suffers from the problems of lower modulation efficiency and slower modulation rates. In this article, the Drude model in combination with the multiple thin layers structure model and Fresnel matrix method is used to compare the modulation efficiencies of three modulation modes and more factors. The method is more accurate than the popular proposed method, especially when the thickness of the excited photoconductive layers reaches a few hundred microns. In comparing the three modes, namely transmission, ordinary reflection and total internal reflection, it is found the total internal reflection modulation mode has the best modulation efficiency. Further, under this mode, the effects of three factors, including the lifetime of photo-excited carriers, the wavelength of pump light and the frequency of THz wave, on the performance of THz modulator are analyzed. The simulation results show that the realization of total internal reflection using silicon prisms is a simple and effective method to improve the modulation efficiency of a silicon-based optically excited THz modulator, which provides references for the design of a photo-induced THz modulator.