Active compression bandages made of electro-mechanically active elastomers have recently been proposed to counteract dynamically, rather than statically, limb swelling due to various pathologies or conditions. To apply and modulate the compression pressure they exploit the ability of electroactive elastomer layer/s of changing size in response to a high voltage. For safety reasons such devices must be properly insulated from the user limb. In this work we present an electroactive bandage made of two pre-stretched layers of an electroactive acrylic elastomer sandwiched between two insulating layers of a passive silicone elastomer. Moreover, uniaxial stiffening elements were introduced to maximise actuation along the radial direction. Prototypes of the bandage were tested with a pressurized air chamber, which mimicked the compliance of a human limb. Experimental investigations and a finite electro-elasticity analytical model showed that the passive layers play a key role for an effective transmission of actuation from the active layers to the load. The prototypes were able to actively vary the applied pressure up to 10%. The model showed that by increasing the number of electroactive layers the pressure variation could be further increased, although with a saturation trend, providing useful indication for future designs of such bandages.
Dielectric elastomer actuators (DEAs) have been demonstrated to represent today a high-performance technology for electroactive polymer mechatronics. As a means to improve versatility and safety of DEAs, so-called “hydrostatically coupled” DEAs (HC-DEAs) have recently been shown to offer new opportunities. HC-DEAs are based on an incompressible fluid that mechanically couples a DE-based active part to a passive part interfaced to the load, so as to enable hydrostatic transmission. Drawing inspiration from this concept, this paper presents a new kind of actuators, analogous to HC-DEAs, except for the fact that the fluid is replaced by fine powder. The related technology, here referred to as “granularly coupled” DEAs (GC-DEAs), relies entirely on solid-state materials. This permits to avoid drawbacks (such as handling and leakage) inherent to usage of fluids, especially those in liquid phase. This paper presents functionality and actuation performance of bubble-like GC-DEAs, in direct comparison with HC-DEAs. For this purpose, prototype actuators made of two prestretched membranes (2-cm wide and less than 2-mm high) of acrylic elastomer, coupled via talcum powder (for GC-DEA) or silicone grease (for HC-DEA), were manufactured and comparatively tested. As compared to HC-DEAs, GC-DEAs showed a higher maximum stress (2.1 kPa), the same maximum relative displacement (-100%), the same -3 dB bandwidth (3 Hz), and a higher resonance frequency (200 Hz). Advantages and drawbacks of GC-DEAs, in comparison with HC-DEAs, are preliminarily identified and discussed.
Continuous monitoring of flexions of the trunk via wearable sensors could help various types of workers to reduce risks associated with incorrect postures and movements. Stretchable piezo-capacitive elastomeric sensors based on dielectric elastomers have recently been described as a wearable, lightweight and cost-effective technology to monitor human kinematics. Their stretching causes an increase of capacitance, which can be related to angular movements. Here, we describe a wearable wireless system to detect flexions of the trunk, based on such sensors. In particular, we present: (i) a comparison of different calibration strategies for the capacitive sensors, using either an accelerometer or a gyroscope as an inclinometer; (ii) a comparison of the capacitive sensors’ performance with those of the accelerometer and gyroscope; to that aim, the three types of sensors were evaluated relative to stereophotogrammetry. Compared to the gyroscope, the capacitive sensors showed a higher accuracy. Compared to the accelerometer, their performance was lower when used as quasi-static inclinometers but also higher in case of highly dynamic accelerations. This makes the capacitive sensors attractive as a complementary, rather than alternative, technology to inertial sensors.
A bioinspired electrically tunable lens made of dielectric elastomer “artificial muscles” is presented by Carpi and coworkers on page 4152. The cover image shows a schematic sectional view of the all-polymer device, which is inspired by the architecture of the crystalline lens and ciliary muscle of the human eye. The background image is a detail of a drawing by Leonardo da Vinci (“A study of the proportions of the eye and eyelid” - Royal Library of Turin, # 15574). In the paper, the authors show that upon electrical activation, the elastomeric artificial muscle is able to deform the fluidfilled elastomeric lens, producing a relative variation of focal length comparable to that of the human lens.
Reliable, easy-to-use, and cost-effective wearable sensors are desirable for continuous measurements of flexions and torsions of the trunk, in order to assess risks and prevent injuries related to body movements in various contexts. Piezo-capacitive stretch sensors, made of dielectric elastomer membranes coated with compliant electrodes, have recently been described as a wearable, lightweight and low-cost technology to monitor body kinematics. An increase of their capacitance upon stretching can be used to sense angular movements. Here, we report on a wearable wireless system that, using two sensing stripes arranged on shoulder straps, can detect flexions and torsions of the trunk, following a simple and fast calibration with a conventional tri-axial gyroscope on board. The piezo-capacitive sensors avoid the errors that would be introduced by continuous sensing with a gyroscope, due to its typical drift. Relative to stereophotogrammetry (non-wearable standard system for motion capture), pure flexions and pure torsions could be detected by the piezo-capacitive sensors with a root mean square error of ~8° and ~12°, respectively, whilst for flexion and torsion components in compound movements, the error was ~13° and ~15°, respectively.