Charnchai Pluempitiwiriyawej

Prof. Dr. Charnchai Pluempitiwiriyawej


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2015 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
JPJaroonrut Prinyakupt
Jaroonrut Prinyakupt
CPCharnchai Pluempitiwiriyawej
Charnchai Pluempitiwiriyawej
Blood smear microscopic images are routinely investigated by haematologists to diagnose most blood diseases. However, the task is quite tedious and time consuming. An automatic detection and classification of white blood cells within such images can accelerate the process tremendously. In this paper we propose a system to locate white blood cells within microscopic blood smear images, segment them into nucleus and cytoplasm regions, extract suitable features and finally, classify them into five types: basophil, eosinophil, neutrophil, lymphocyte and monocyte. Two sets of blood smear images were used in this study’s experiments. Dataset 1, collected from Rangsit University, were normal peripheral blood slides under light microscope with 100× magnification; 555 images with 601 white blood cells were captured by a Nikon DS-Fi2 high-definition color camera and saved in JPG format of size 960 × 1,280 pixels at 15 pixels per 1 μm resolution. In dataset 2, 477 cropped white blood cell images were downloaded from CellaVision.com. They are in JPG format of size 360 × 363 pixels. The resolution is estimated to be 10 pixels per 1 μm. The proposed system comprises a pre-processing step, nucleus segmentation, cell segmentation, feature extraction, feature selection and classification. The main concept of the segmentation algorithm employed uses white blood cell’s morphological properties and the calibrated size of a real cell relative to image resolution. The segmentation process combined thresholding, morphological operation and ellipse curve fitting. Consequently, several features were extracted from the segmented nucleus and cytoplasm regions. Prominent features were then chosen by a greedy search algorithm called sequential forward selection. Finally, with a set of selected prominent features, both linear and naïve Bayes classifiers were applied for performance comparison. This system was tested on normal peripheral blood smear slide images from two datasets. Two sets of comparison were performed: segmentation and classification. The automatically segmented results were compared to the ones obtained manually by a haematologist. It was found that the proposed method is consistent and coherent in both datasets, with dice similarity of 98.9 and 91.6% for average segmented nucleus and cell regions, respectively. Furthermore, the overall correction rate in the classification phase is about 98 and 94% for linear and naïve Bayes models, respectively. The proposed system, based on normal white blood cell morphology and its characteristics, was applied to two different datasets. The results of the calibrated segmentation process on both datasets are fast, robust, efficient and coherent. Meanwhile, the classification of normal white blood cells into five types shows high sensitivity in both linear and naïve Bayes models, with slightly better results in the linear classifier.

21 July 2022 in Computation
Verified
Journal Article
Open access
PDF file
Hsumonlei AungHsumonlei Aung
Hsumonlei Aung
CPCharnchai Pluempitiwiriyawej
Charnchai Pluempitiwiriyawej
Kazuhiko HamamotoKazuhiko Hamamoto
Kazuhiko Hamamoto
SWSomkiat Wangsiripitak
Somkiat Wangsiripitak
Biometric recognition is a critical task in security control systems. Although the face has long been widely accepted as a practical biometric for human recognition, it can be easily stolen and imitated. Moreover, in video surveillance, it is a challenge to obtain reliable facial information from an image taken at a long distance with a low-resolution camera. Gait, on the other hand, has been recently used for human recognition because gait is not easy to replicate, and reliable information can be obtained from a low-resolution camera at a long distance. However, the gait biometric alone still has constraints due to its intrinsic factors. In this paper, we propose a multimodal biometrics system by combining information from both the face and gait. Our proposed system uses a deep convolutional neural network with transfer learning. Our proposed network model learns discriminative spatiotemporal features from gait and facial features from face images. The two extracted features are fused into a common feature space at the feature level. This study conducted experiments on the publicly available CASIA-B gait and Extended Yale-B databases and a dataset of walking videos of 25 users. The proposed model achieves a 97.3 percent classification accuracy with an F1 score of 0.97and an equal error rate (EER) of 0.004.

1 January 2010 in IEICE Transactions on Information and Systems
Verified
Journal Article
Open access
PDF file
SPSopon Phumeechanya
Sopon Phumeechanya
CPCharnchai Pluempitiwiriyawej
Charnchai Pluempitiwiriyawej
STSaowapak Thongvigitmanee
Saowapak Thongvigitmanee
In this paper, we propose a novel active contour method for image segmentation using a local regional information on extendable search line. We call it the LRES active contour. Our active contour uses the intensity values along a set of search lines that are perpendicular to the contour front. These search lines are used to inform the contour front toward which direction to move in order to find the object's boundary. Unlike other methods, none of these search lines have a predetermined length. Instead, their length increases gradually until a boundary of the object is found. We compare the performance of our LRES active contour to other existing active contours, both edge-based and region-based. The results show that our method provides more desirable segmentation outcomes, particularly on some images where other methods may fail. Not only is our method robust to noise and able to reach into a deep concave shape, it also has a large capture range and performs well in segmenting heterogeneous textured objects.

31 October 2025 in Engineering Journal
Verified
Journal Article
Open access
PDF file
MKMudassar Khalid
Mudassar Khalid
CPCharnchai Pluempitiwiriyawej
Charnchai Pluempitiwiriyawej
NWNawaporn Wisitpongphanb
Nawaporn Wisitpongphanb
MSMuhammad Asim Saleem
Muhammad Asim Saleem
SASadia Jabbar Anwar
Sadia Jabbar Anwar
TTTien Truong
Tien Truong
COVID-19 has affected millions of people around the world in the last three years. Despite widespread vaccination efforts, infections persist and definitive treatments remain elusive. Therefore, early and accurate detection of COVID-19 is critical to minimize invasive procedures and reduce mortality. Although radiographs and CT scans are commonly used for the diagnosis of COVID-19, electrocardiogram (ECG) images remain underutilized despite their widespread availability. This limited use can be attributed to the complex transformations required to process ECG data, which increase computational demands. This study proposes a novel hybrid deep learning model ECGNet-ViT for COVID-19 detection. The model combines the multi-scale feature extraction capabilities of GoogleNet (GNet) with Swish activation functions and densely connected layers, and then integrates it with Vision Transformer (ViT) to effectively capture long-range dependencies in classification tasks. This approach can efficiently analyze ECG data and accurately classify samples into five categories: normal, COVID-19, myocardial infarction (MI), previous myocardial infarction (PMI) and arrhythmia (AHB). Comprehensive experiments on a publicly available ECG datasets demonstrate the effectiveness of the proposed model, achieving 99.13% accuracy, 99.19% precision, 99.24% recall, and 99.22% F1 score. These results highlight the potential of the proposed model to provide reliable, non-invasive support in COVID-19 diagnosis based on ECG data.