Blood smear microscopic images are routinely investigated by haematologists to diagnose most blood diseases. However, the task is quite tedious and time consuming. An automatic detection and classification of white blood cells within such images can accelerate the process tremendously. In this paper we propose a system to locate white blood cells within microscopic blood smear images, segment them into nucleus and cytoplasm regions, extract suitable features and finally, classify them into five types: basophil, eosinophil, neutrophil, lymphocyte and monocyte. Two sets of blood smear images were used in this study’s experiments. Dataset 1, collected from Rangsit University, were normal peripheral blood slides under light microscope with 100× magnification; 555 images with 601 white blood cells were captured by a Nikon DS-Fi2 high-definition color camera and saved in JPG format of size 960 × 1,280 pixels at 15 pixels per 1 μm resolution. In dataset 2, 477 cropped white blood cell images were downloaded from CellaVision.com. They are in JPG format of size 360 × 363 pixels. The resolution is estimated to be 10 pixels per 1 μm. The proposed system comprises a pre-processing step, nucleus segmentation, cell segmentation, feature extraction, feature selection and classification. The main concept of the segmentation algorithm employed uses white blood cell’s morphological properties and the calibrated size of a real cell relative to image resolution. The segmentation process combined thresholding, morphological operation and ellipse curve fitting. Consequently, several features were extracted from the segmented nucleus and cytoplasm regions. Prominent features were then chosen by a greedy search algorithm called sequential forward selection. Finally, with a set of selected prominent features, both linear and naïve Bayes classifiers were applied for performance comparison. This system was tested on normal peripheral blood smear slide images from two datasets. Two sets of comparison were performed: segmentation and classification. The automatically segmented results were compared to the ones obtained manually by a haematologist. It was found that the proposed method is consistent and coherent in both datasets, with dice similarity of 98.9 and 91.6% for average segmented nucleus and cell regions, respectively. Furthermore, the overall correction rate in the classification phase is about 98 and 94% for linear and naïve Bayes models, respectively. The proposed system, based on normal white blood cell morphology and its characteristics, was applied to two different datasets. The results of the calibrated segmentation process on both datasets are fast, robust, efficient and coherent. Meanwhile, the classification of normal white blood cells into five types shows high sensitivity in both linear and naïve Bayes models, with slightly better results in the linear classifier.

31 January 2025 in International Journal of Robotics and Control Systems
Verified
Journal Article
Open access
PDF file
PCPhichitphon Chotikunnan
Phichitphon Chotikunnan
YPYutthana Pititheeraphab
Yutthana Pititheeraphab
TAThanate Angsuwatanakul
Thanate Angsuwatanakul
JPJaroonrut Prinyakupt
Jaroonrut Prinyakupt
TPTasawan Puttasakul
Tasawan Puttasakul
NTNuntachai Thongpance
Nuntachai Thongpance
The aim of this research is to improve the precision of factory-locked MG996R servo motors, which are frequently employed in biomedical and robotic applications. These motors are characterized by the absence of inherent feedback channels and adjustable internal settings. The proposed technique proposes a non-invasive control strategy that utilizes externally obtained feedback to enable closed-loop control without requiring any modifications to the interior circuitry. The scientific contribution consists of the development of an outer-loop PID control framework that has been optimized using Particle Swarm Optimization (PSO) and enhanced with feedforward compensation. By utilizing the inherent potentiometer, this method ensures the preservation of hardware integrity and enables real-time angle feedback. A model fit of 96.94% was achieved by establishing a second-order discrete-time model using MATLAB's System Identification Toolbox. Particle Swarm Optimization (PSO) was employed to optimize PID improvements offline by minimizing the Integral of Squared Error (ISE). In both experimental and simulated environments, the controller's effectiveness was assessed using 2 rad/s sine wave inputs and a 10° step. The PSO-PID with feedforward controller achieved optimal results, achieving an RMSE of 0.5313° and an MAE of 0.1630° in simulations, as well as an MAE of 0.8497° in hardware step response. The requirement for gain scaling in embedded systems was underscored by the instability of the standalone PSO-PID controller. This method offers a pragmatic, scalable solution for applications such as assistive robotics, prosthetic joints, and surgical instruments. In order to achieve sub-degree precision in safety-critical environments, future endeavors will entail the implementation of adaptive gain tuning and enhanced resolution sensing.

1 November 2019
Verified
Conference Paper
Closed access
JPJaroonrut Prinyakupt
Jaroonrut Prinyakupt
TYThanakorn Yootho
Thanakorn Yootho
This paper aims to design and construction of the palm and foot warmers for pediatric patients, who are in shock situation in the ICU. The designed device was used to reducing the risk of tissue deficiency in the palms and feet according to the requirements of the Queen Sirikit National Institute of Child Health (Children's Hospital). This device acted as a hot air generator, controlled the temperature of the hot air send to the pediatric patient's gloves and socks, which serves to store hot air. The working temperature was in the range of 36.5°C to 37.5°C. This device consists of 2 main parts: 1) hot air generator consisting of air pump, heater chamber, solid-state relay, electromechanical relay, temperature sensors, microcontroller, over temperature protection circuit (40°C), display and alarm. The program control was written with C language and 2) gloves and socks were made from black cotton fabric and connected to the silicone rubber hose. The other end of the hose was connected to the hot air generator. The performance testing on this device according to the standard calibration devices composed of: 1) the results of the internal temperature of gloves and socks testing with the Fluke 289 True RMS Multimeter found that it can control the temperature in the gloves and socks at 36.5°C to 37.5°C after warming up the device for 50 minutes and 60 minutes respectively, according to doctor's requirements and 2) electrical leakage testing results with the Fluke ESA 612 Electrical Safety Analyzer found that a maximum Average leakage current was 85.30μA within the standard recommended by IEC 60601-1 (IEC: International Electrotechique Commission) was not more than 500μA.

15 October 2026 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
TYThanakorn Yootho
Thanakorn Yootho
JPJaroonrut Prinyakupt
Jaroonrut Prinyakupt
We design and construct a prone positioning device for postural drainage therapy. The device uses a linear motor control system to extend and retract its structure, allowing controlled elevation and lowering of the device. The mechanism maintains an adjustable angle between 30° and 45° relative to the horizontal plane to facilitate effective sputum drainage. Functional testing and performance evaluation demonstrated that the device operates according to the design specifications, operational safety, and structural stability. The integrated structural and control system successfully lifted and supported loads ranging from 40 to 80 kg and operated continuously for 30 min without structural failure or mechanical malfunction. The results indicate that the proposed device provides sufficient stability, operational safety, and reliability for postural drainage applications.

6 May 2024 in International Journal of Online and Biomedical Engineering (iJOE)
Verified
Journal Article
Open access
PDF file
JPJaroonrut Prinyakupt
Jaroonrut Prinyakupt
TYThanakorn Yootho
Thanakorn Yootho
The purpose of this study was to design and build a mechanical vibration assessment tool for diabetic patients’ peripheral nervous systems. There is a substantial correlation between peripheral sensory neuropathy and vibration perception threshold (VPT). Peripheral sensory neuropathy has been identified by VPT determination utilizing the VPT measurement instrument built for that purpose. The designed device can assist in determining the threshold and tracking any progressive changes or trends. This designed device consists of two main components: hardware and software. The hardware part includes a DC power supply circuit, an Arduino NANO, a display, an isolation MOSFET driver for the electrical isolation circuit, a transducer driver, and a transducer head. The software part uses C programming on the Arduino to generate signals and display the transducer supply voltage. The testing results consist of 1) the voltage settings results (5–30 volts) comparing the voltage values on the display between the designed device and a digital multimeter, which has an average error of 0.75%, 2) According to the transducer head pressing test results, the Vibrotest Digital Biothesiometer and the proposed device had different pressing weights of ±0.02 g, and 3) the electrical safety testing results of the designed device is in the standard of IEC60601-1. (IEC: International Electrotechnical Commission).

12 December 2023 in Materials Science Forum
Verified
Journal Article
Closed access
PDF file
TTThaman Toobunterng
Thaman Toobunterng
CSChakrit Suvanjumrat
Chakrit Suvanjumrat
JPJaroonrut Prinyakupt
Jaroonrut Prinyakupt
The objective of this research is to investigate the properties of standardized foam materials in clinical balance testing, assuming that the behavior of the foam material is hyperelastic. To simulate the deformation behavior, the finite element method was used in conjunction with the behavior of hyperelastic materials. We perform a value of the properties of materials without the use of destructive compression testing samples. Compression tests were performed on real materials according to standardized test methods that did not cause the destruction of the actual material. The collected data were then used to generate stress-strain relationship curves and compare them with different behavior models of hyperelastic materials using the finite element method. The behavior model of Ogden hyperelastic materials showed the highest similarity to the behavior of foam materials.