Ying Guan

Ms. Ying Guan

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
YGYing Guan
Ying Guan
JLJing Lin
Jing Lin
ZDZhihui Dong Zhihui Dong
Zhihui Dong Zhihui Dong
LWLu Wang
Lu Wang
The complication of stent graft‐induced new entry (SINE) after thoracic endovascular aortic repair (TEVAR) may be caused by the spring‐back force of both ends of the stent grafts. Spring‐back force, which is exerted by the curvature and ends of stent grafts on the greater wall of the aorta, suggests poor flexibility. Research on stent graft flexibility via design optimization has been widely disregarded. Thus, this study investigates the relationship between stent graft structure and flexibility by measuring bending and spring‐back forces. Stent spacing (5, 10, and 15 mm), apex angle (30° and 45°), and strut configuration (Z‐ and M‐stented) were considered for the structural parameters. The overall tendency of spring‐back and bending forces was similar. The stent graft with 15 mm spacing attained the lowest force level. The force difference between samples with 30° and 45° apex angles became prominent as the curving angle increased. The sample with 45° stent apex attained low force value. The Z‐stented graft obtained a lower force than the M‐stented graft with the same number of struts per hoop. Consequently, optimal flexibility was obtained when the structural design was characterized by long stent spacing, big stent apex angle, and Z‐type strut configuration.

5 August 2016 in Materials
Verified
Journal Article
Open access
PDF file
YGYing Guan
Ying Guan
LWLu Wang
Lu Wang
Jing LinJing Lin
Jing Lin
Martin W KingMartin W King
Martin W King
Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU) and polyester graft (nitinol-PET) materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.