This study explored the ideal period for wearing masks to prevent the physiological and psychological problems associated with long-term face mask use during respiratory infections by healthcare workers. Breathing simulators, surgical masks (SM) and medical respirators (PM) were prepared for two to eight hours. Changes in the comfort of masks (facial skin temperature, breathing resistance, and moisture permeability) and protection (filtration efficiency, resistance to blood penetration, and colony count) were assessed. The results demonstrated that the masks offered efficient liquid-particle filtering even after eight hours of use. However, the number of bacterial colonies using PM and SM grew significantly after two and four hours, respectively. Concerning comfort, the inspiratory resistance of masks rose dramatically after two hours, whereas the moisture permeability declined considerably after four hours. In addition, skin temperature had a significant increase within two hours, which may result in facial discomfort. When conditions permitted, the hospital staff was instructed to replace their masks every two hours.
Whereas buckling can cause type III endoleaks, long-term twisting of a stent-graft was investigated here as a mechanism leading to type V endoleak or endotension. Two experimental device designs supported with Z-stents having strut angles of 35° or 45° were compared to a ringed control under accelerated twisting. Damage to each device was assessed and compared after different durations of twisting, with focus on damage that may allow leakage. Stent-grafts with 35° Z-stents had the most severe distortion and damage to the graft fabric. The 45° Z-stents caused less fabric damage. However, consistent stretching was still seen around the holes for sutures, which attach the stents to the graft fabric. Larger holes may become channels for fluid percolation through the wall. The ringed stent-graft had the least damage observed. Stent apexes with sharp angles appear to be responsible for major damage to the fabrics. Device manufacturers should consider stent apex angle when designing stent-grafts, and ensure their devices are resistant to twisting.
Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU) and polyester graft (nitinol-PET) materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.
In situ fenestration of endovascular stent-grafts has become a mainstream bailout technique to treat complex emergent aneurysms while maintaining native anatomical visceral and aortic arch blood supplies. Fabric tearing from creating the in situ fenestration using balloon angioplasty may extend beyond the intended diameter over time. Further tearing may result from the physiologic pulsatile motion at the branching site. A resultant endoleak at the fenestrated sites in stent-grafts could ultimately lead to re-pressurization of the aortic sac and, eventually, rupture. In an attempt to address this challenge, plain woven fabrics were designed. They hold a specific corona surrounding a square-shaped cluster with a plain weave fabric structure, a 2/2 twill, or a honeycomb. The corona was designed to stop potential further tearing of the fabric caused by the initial balloon angioplasty and stent or later post-implantation motion. The cluster within the corona was designed with relatively loose fabric structures (plain weave, 2/2 twill weave, and honeycomb) to facilitate the laser fenestration. Two commercial devices, Anaconda (Vascutek, Terumo Aortic) and Zenith TX2 (Cook), were selected as controls for comparison against this new design. All the specimens were characterized by morphology, thickness, and water permeability. The results demonstrated that all specimens with a low thickness and water permeability satisfied the requirements for a stent graft material that would be low profile and resistant to endoleaks. The in situ fenestrations were performed on all fabrics utilizing an Excimer laser followed by balloon angioplasty. The fabrics were further observed by light microscopy and scanning electron microscopy. The dimension of the fenestrated apertures was smaller than the balloon’s diameter. The tearing was effectively confined within the corona. The clinical acceptability of this concept deserves additional bench testing and animal experimentation.
Compression therapy is a widely used strategy for preventing post-burn scars, managing lymphedema, and rehabilitation after liposuction. However, commercially available compression garments often struggle with rapid pressure decay during clinical use. To address this issue, an adaptive fatigue-resistant knitted arm sleeve has been designed and prepared using nitinol wires in the present study, aiming to explore the feasibility of integrating shape memory wires into compression garments. The objective is to combat rapid pressure decay of the compression garments by shape memory effect of nitinol wires. Initially, nitinol wires were subjected to heat treatment at 475 °C for 20 min, allowing for precise control over phase transition within a narrow range of less than 5 °C. The treated wires exhibited a shape recovery rate ( η ) of 93.22% and a martensite finish temperature ( Mf ) of 30.1 °C, close to surface temperature of human skin. Next, two types of knitted sleeves were fabricated, Sleeve A (dense) and Sleeve B (loose). Moreover, comprehensive characterisations have been carried out. The results showed that both sleeves exhibited favourable temperature response and fatigue-resistant property. They showed a maximum elastic recovery rate of 96.36% and maintained a minimum stress relaxation rate as low as 2.97%. Importantly, both sleeves sustained stable pressure during cyclic loading tests simulating three consecutive days of wear (cumulatively 22.5 h), demonstrating promising fatigue resistance during wear. Additionally, Sleeve A generated a pressure of 52.53 mmHg at 30% strain due to the shape memory effect, representing a 25.3% increase in pressure after thermal activation. The developed compression sleeves displayed remarkable shape memory properties, achieving maximum shape recovery and shape fixation rates of 97.4% and 95.37%, respectively. Overall, this study offers valuable theoretical insights and practical foundations for developing innovative, fatigue-resistant, adaptive compression garments, while highlighting the need for further clinical validation to establish therapeutic efficacy.