YASUSHI UEYANAGI

Mr. YASUSHI UEYANAGI

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
YUYASUSHI UEYANAGI
YASUSHI UEYANAGI
DSDaiki Setoyama
Daiki Setoyama
DKDaisuke Kawakami
Daisuke Kawakami
YMYuichi Mushimoto
Yuichi Mushimoto
SMShinya Matsumoto
Shinya Matsumoto
DKDongchon Kang
Dongchon Kang
Gas chromatography-mass spectrometry has been widely used to analyze hundreds of organic acids in urine to provide a diagnostic basis for organic acidemia. However, it is difficult to operate in clinical laboratories on a daily basis due to sample pretreatment processing. Therefore, we aimed to develop a fully automated system for quantifying serum organic acids using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The pretreatment CLAM-2030 device was connected to an LC-MS/MS system for processing serum under optimized conditions, which included derivatizing serum organic acids using 3-Nitrophenylhydrazine. The derivatized organic acids were separated on a reverse-phase Sceptor HD-C column and detected using negative-ion electrospray ionization multiple reaction monitoring MS. The automated pretreatment-LC-MS/MS system processed serum in less than 1 h and analyzed 19 serum organic acids, which are used to detect organic acidemias. The system exhibited high quantitative sensitivity ranging from approximately 2 to 100 µM with a measurement reproducibility of 10.4% CV. Moreover, a proof-of-concept validation of the system was performed using sera from patients with propionic acidemia (n = 5), methylmalonic acidemia (n = 2), and 3-methylcrotonylglycinuria (n = 1). The levels of marker organic acids specific to each disease were significantly elevated in the sera of the patients compared to those in control samples. The automated pretreatment-LC-MS/MS system can be used as a rapid in-hospital system to measure organic acid levels in serum for the diagnosis of organic acidemias.

19 March 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
YUYASUSHI UEYANAGI
YASUSHI UEYANAGI
DSDaiki Setoyama
Daiki Setoyama
TNTsuyoshi Nakanishi
Tsuyoshi Nakanishi
YMYuichi Mushimoto
Yuichi Mushimoto
VTVlad Tocan
Vlad Tocan
YKYuya Kunisaki
Yuya Kunisaki
Background/Objectives: Conventional diagnosis of inborn errors of metabolism (IEMs) requires multiple specimen types—urine organic acids, plasma amino acids, and serum acylcarnitines—analyzed on distinct analytical platforms. This multi-assay approach is labor-intensive and limits timely clinical decision making. We aimed to develop a fully automated serum-based LC–MS/MS platform for integrated quantitative metabolite profiling and to establish pediatric reference intervals (RIs) to support diagnostic interpretation. Methods: A fully automated LC–MS/MS system integrated with the CLAM-2030 automated pretreatment module was developed to enable simultaneous quantification of 25 organic acids, 8 amino acids, and 21 acylcarnitines. Analytical performance was assessed for linearity, limits of detection and quantification, precision and accuracy. Serum samples from 296 non-IEM children aged 0–6 years were analyzed to establish pediatric RIs using Box–Cox transformation and Gaussian modeling. Clinical utility was evaluated in sera from 89 patients diagnosed with IEM using z-score-based logistic regression models. Results: The method demonstrated excellent performance, with linearity (r2 > 0.99) across calibration ranges, limits of detection and quantification defined by signal-to-noise ratios > 3 and >10, and intra- and inter-assay precision < 15% CV for all 54 analytes. Twenty-one analytes met the acceptance criterion of ±20% accuracy at all quality-control levels. Pediatric RIs provided a quantitative framework for interpreting the metabolic abnormalities. In IEM patients, disease-specific metabolites were consistently outside the established ranges, and z-score-based logistic regression models successfully distinguished major IEM categories, including organic acidemias and long-chain fatty acid oxidation disorders. Conclusions: This fully automated, serum-based LC–MS/MS platform provides a clinically practical and quantitative framework for integrated metabolic profiling using pediatric RIs, supporting diagnosis and monitoring of IEMs in pediatric settings.