Tsuyoshi Nakanishi

Tsuyoshi Nakanishi

Auto-generated profile, based on publicly available information

Tsuyoshi Nakanishi

Analytical and Measuring Instruments Division, Shimadzu Corporation, Kyoto 604-8511, Japan

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2006 in Journal of Chromatography B
Verified
Journal Article
Closed access
TNTsuyoshi Nakanishi
Tsuyoshi Nakanishi
EAEiji Ando
Eiji Ando
MFMasaru Furuta
Masaru Furuta
STSusumu Tsunasawa
Susumu Tsunasawa
ONOsamu Nishimura
Osamu Nishimura

1 February 2021 in Journal of Bioscience and Bioengineering
Verified
Journal Article
Closed access
SKShinji Kanazawa
Shinji Kanazawa
ANAkira Noda
Akira Noda
AIArisa Ito
Arisa Ito
KHKyoko Hashimoto
Kyoko Hashimoto
AKAkihiro Kunisawa
Akihiro Kunisawa
FMFumio Matsuda
Fumio Matsuda

19 March 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
YUYASUSHI UEYANAGI
YASUSHI UEYANAGI
DSDaiki Setoyama
Daiki Setoyama
TNTsuyoshi Nakanishi
Tsuyoshi Nakanishi
YMYuichi Mushimoto
Yuichi Mushimoto
VTVlad Tocan
Vlad Tocan
YKYuya Kunisaki
Yuya Kunisaki
Background/Objectives: Conventional diagnosis of inborn errors of metabolism (IEMs) requires multiple specimen types—urine organic acids, plasma amino acids, and serum acylcarnitines—analyzed on distinct analytical platforms. This multi-assay approach is labor-intensive and limits timely clinical decision making. We aimed to develop a fully automated serum-based LC–MS/MS platform for integrated quantitative metabolite profiling and to establish pediatric reference intervals (RIs) to support diagnostic interpretation. Methods: A fully automated LC–MS/MS system integrated with the CLAM-2030 automated pretreatment module was developed to enable simultaneous quantification of 25 organic acids, 8 amino acids, and 21 acylcarnitines. Analytical performance was assessed for linearity, limits of detection and quantification, precision and accuracy. Serum samples from 296 non-IEM children aged 0–6 years were analyzed to establish pediatric RIs using Box–Cox transformation and Gaussian modeling. Clinical utility was evaluated in sera from 89 patients diagnosed with IEM using z-score-based logistic regression models. Results: The method demonstrated excellent performance, with linearity (r2 > 0.99) across calibration ranges, limits of detection and quantification defined by signal-to-noise ratios > 3 and >10, and intra- and inter-assay precision < 15% CV for all 54 analytes. Twenty-one analytes met the acceptance criterion of ±20% accuracy at all quality-control levels. Pediatric RIs provided a quantitative framework for interpreting the metabolic abnormalities. In IEM patients, disease-specific metabolites were consistently outside the established ranges, and z-score-based logistic regression models successfully distinguished major IEM categories, including organic acidemias and long-chain fatty acid oxidation disorders. Conclusions: This fully automated, serum-based LC–MS/MS platform provides a clinically practical and quantitative framework for integrated metabolic profiling using pediatric RIs, supporting diagnosis and monitoring of IEMs in pediatric settings.

4 September 2026 in Biomedicines
Verified
Journal Article
Open access
PDF file
HMHiroyasu Miyamoto
Hiroyasu Miyamoto
RKReiko Kisugi
Reiko Kisugi
ATAyasa Tajima
Ayasa Tajima
MMMasaki Miyasaka
Masaki Miyasaka
TMTomokazu Matsuura
Tomokazu Matsuura
Sae OchiSae Ochi
Sae Ochi
Background/Objectives: Vitamin D is a pleiotropic substance that plays a pivotal role in the human body. Several studies have suggested sex-based differences in vitamin D metabolism. Recently, the vitamin D metabolite ratio (VMR), defined as the ratio of serum 24,25-dihydroxyvitamin D [24,25(OH)2D] to 25-hydroxyvitamin D [25(OH)D], has been identified as a novel marker that may more accurately reflect vitamin D status than serum 25(OH)D alone. This study aimed to assess whether significant variability exists in the VMR across different demographic groups. Methods: Residual serum samples and laboratory data were collected from healthy adults who underwent health checkups at a health center in Japan. Serum concentrations of 25(OH)D3 and 24,25(OH)2D3 were simultaneously measured using a fully automated liquid chromatography–tandem mass spectrometry (LC-MS/MS) system. Factors affecting the levels of 25(OH)D3, 24,25(OH)2D3, and VMR were analyzed using multiple regression analysis and the stabilized inverse probability weighting method. Results: Tentative reference intervals for 24,25(OH)2D3 were found to be 0.3–3.0 ng/mL for males and 0.2–2.3 ng/mL for females. Those for VMR were found to be 3.0–11.8% for males and 2.5–10.4% for females, demonstrating statistically significant but moderate differences between the sexes. These differences remained significant even after adjusting for baseline covariates including 25(OH)D3. However, the standard deviation ratios were less than 0.5. An estimated glomerular filtration rate and an age of ≥50 years were positively associated with 24,25(OH)2D3 and VMR, whereas diabetic status was negatively associated with these markers. Conclusions: This study revealed moderate sex-based differences in markers of vitamin D metabolism. Although further research is needed to determine whether these differences are consistent across other populations, future epidemiology and clinical interventions should take into consideration of the sex-based differences in vitamin D metabolism.