This study explores the impact of wall luminance and correlated colour temperature (CCT) on the observers’ brightness perception and scene preference in a controlled, windowless office environment. A two-interval-forced-choice experiment was conducted with the 20 lighting scenes derived from five CCTs (2500–10 000 K) and four luminances (12–120 cd/m²). The results from 20 observers showed that a higher wall luminance significantly increased brightness. At equal luminances, different CCT values had no significant effect on brightness, consistent with some reports that CCT is not a reliable predictor of brightness when other photometric factors are held constant. Scene preference increased as wall luminance increased to approximately 72 cd/m², but a further increase in wall luminance to 120 cd/m² had no significant impact on preference. As the CCT increased from 2500 K, the preference increased up to approximately 4000 K, followed by a substantial decline from 5715 to 10 000 K.
1 January 2006 in IEE Proceedings - Electric Power Applications
To reduce the voltage distortion in a distribution network, parallel (shunt) harmonic impedances (SHIs) can be strategically positioned in the network. However, to avoid the additional cost of adding SHIs to the distribution network, the SHI function can be implemented as it secondary function of convertors connecting loads or generators to the mains. A control strategy for a single-phase bidirectional full-bridge AC-DC convertor is proposed. This control strategy allows a fixed resistive impedance to be programmed for harmonics, independent of the direction of the fundamental power flow. Hence, the bidirectional rectifier obtained behaves, as a secondary function, like a resistive SHI, providing damping for resonances and resulting in an overall improvement of the voltage distortion in the distribution network. The theoretical results obtained are verified by using an experimental test setup. The Superior damping potential of the experimental bidirectional rectifier with the proposed control scheme is demonstrated by a comparison with experimental results previously obtained for 'classical' control schemes
10 September 2024 in Lighting Research & Technology
In this work, it is investigated how reading comfort is influenced by monitor and ambient luminance levels, when employing high-luminance monitors. High-luminance monitors can be used to get more light on the eye and elicit non-image-forming effects. However, this might lead to reduced reading comfort. Two psychophysical methods, a continuous rating scale and paired comparison, were employed to investigate reading comfort in relation to the luminance of the monitor and the ambient environment. The results of 18 observers for the continuous rating scale experiment (aged 20 y to 30 y) and 20 observers for the paired comparison experiment (aged 20 y to 37 y) indicate that reading comfort is significantly influenced by both monitor and ambient luminance levels The paired comparison methodology provided more distinctive capabilities and thus offered a deeper insight. In contrast to prior work suggesting a linear relation between monitor luminance and preferred ambient luminance, the current results indicate that the reading comfort level reaches a tipping or saturation point. A monitor luminance level of 260 cd m−2 combined with an ambient luminance level of 68 cd m−2 provided the highest reading comfort. This reading comfort could not be matched when employing a higher monitor luminance level of 700 cd m−2.
Dose-response curves for circadian phase shift and melatonin suppression in relation to white or monochromatic nighttime illumination can be scaled to melanopic weighed illumination for normally constricted pupils, which makes them easier to interpret and compare. This is helpful for a practical applications.
High-luminance light sources are challenging to achieve with light-emitting diodes (LEDs) due to power droop. Since laser diodes (LDs) do not suffer from power droop, they can be used as an alternative. A novel, to the best of our knowledge, high-luminance white light source was developed utilizing LDs combined with a sediment silicone/phosphor composite. The deposition of this sediment phosphor inside an aluminum spacer on top of a sapphire backplate ensures optimal thermal management. To enhance the optical performance, the sapphire plate is coated with a custom-designed blue pass filter in order to recycle most of the converted light that is emitted in the backward direction. The maximal obtained luminance of this light source is 103 MCd/m2 at a luminous flux of 3119 lm.