Gheorghe Tomoaia

Gheorghe Tomoaia


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
DODaniel Oltean-Dan
Daniel Oltean-Dan
GDGabriela-Bombonica Dogaru
Gabriela-Bombonica Dogaru
MTMaria Tomoaia-Cotisel
Maria Tomoaia-Cotisel
DADragos Apostu
Dragos Apostu
AMAlexandru Mester
Alexandru Mester
GTGheorghe Tomoaia
Gheorghe Tomoaia
Purpose: Bone consolidation after severe trauma is the most challenging task in orthopedic surgery. This study aimed to develop biomimetic composite for coating Ti implants. Afterwards, these implants were tested in vivo to assess bone consolidation in the absence or the presence of high-frequency pulsed electromagnetic short-waves (HF-PESW). Materials: Biomimetic coating was successfully developed using multi-substituted hydroxyapatite (ms-HAP) functionalized with collagen (ms-HAP/COL), embedded into poly-lactic acid (PLA) matrix (ms-HAP/COL@PLA), and subsequently covered with self-assembled COL layer (ms-HAP/COL@PLA/COL, named HAPc). Methods: For in vivo evaluation, 32 Wistar albino rats were used in four groups: control group (CG) with Ti implant; PESW group with Ti implant+HF-PESW; HAPc group with Ti implant coated with HAPc; HAPc+PESW group with Ti implant coated with HAPc+HF-PESW. Left femoral diaphysis was fractured and fixed intramedullary. From the first post-operative day, PESW and HAPc+PESW groups underwent HF-PESW stimulation for 14 consecutive days. Biomimetic coating was characterized by XRD, HR-TEM, SEM, EDX and AFM. Results: Osteogenic markers (ALP and osteocalcin) and micro-computed tomography (CT) analysis (especially bone volume/tissue volume ratio results) indicated at 2 weeks the following group order: HAPc+PESW>HAPc≈PESW (P>0.05) and HAPc+PESW>control (P<0.05), indicating the higher values in HAPc+PESW group compared to CG. The fracture-site bone strength showed, at 2 weeks, the highest average value in HAPc+PESW group. Moreover, histological analysis revealed the most abundant COL fibers assembled in dense bundles in HAPc-PESW group. At 8 weeks, micro-CT indicated higher values only in HAPc+PESW group vs CG (P<0.05), and histological results showed a complete-healed fracture in groups: HAPc+PESW, HAPc and PESW, but with more advanced bone remodeling in HAPc+PESW group. Conclusion: Using Ti implants coated by HAPc jointly with HF-PESW stimulation positively influenced the bone consolidation process, especially in its early phase, thus potentially providing a superior strategy for clinical applications.

31 October 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
DODaniel Oltean-Dan
Daniel Oltean-Dan
GDGabriela Dogaru
Gabriela Dogaru
MJMihaela Elena Jianu
Mihaela Elena Jianu
Sorin RigaSorin Riga
Sorin Riga
MTMaria Tomoaia-Cotisel
Maria Tomoaia-Cotisel
GTGheorghe Tomoaia
Gheorghe Tomoaia
Innovative nanomaterials are required for the coatings of titanium (Ti) implants to ensure the activation of Ti surfaces for improved osseointegration, enhanced bone fracture healing and bone regeneration. This paper presents a systematic investigation of biomimetic composite (BC) coatings on Ti implant surfaces in a rat model of a diaphyseal femoral fracture. Methodological approaches of surface modification of the Ti implants via the usual joining methods (e.g., grit blasting and acid etching) and advanced physicochemical coating via a self-assembled dip-coating method were used. The biomimetic procedure used multi-substituted hydroxyapatite (ms-HAP) HAP-1.5 wt% Mg-0.2 wt% Zn-0.2 wt% Si nanoparticles (NPs), which were functionalized using collagen type 1 molecules (COL), resulting in ms-HAP/COL (core/shell) NPs that were embedded into a polylactic acid (PLA) matrix and finally covered with COL layers, obtaining the ms-HAP/COL@PLA/COL composite. To assess the osseointegration issue, first, the thickness, surface morphology and roughness of the BC coating on the Ti implants were determined using AFM and SEM. The BC-coated Ti implants and uncoated Ti implants were then used in Wistar albino rats with a diaphyseal femoral fracture, both in the absence and the presence of high-frequency pulsed electromagnetic shortwave (HF-PESW) stimulation. This study was performed using a bone marker serum concentration and histological and computer tomography (micro-CT) analysis at 2 and 8 weeks after surgical implantation. The implant osseointegration was evaluated through the bone–implant contact (BIC). The bone–implant interface was investigated using FE-SEM images and EDX spectra of the retrieved surgical implants at 8 weeks in the four animal groups. The obtained results showed significantly higher bone–implants contact and bone volume per tissue volume, as well as a greater amount of newly formed bone, in the BC-coated Ti implants than in the uncoated Ti implants. Direct bone–implant contact was also confirmed via histological examination. The results of this study confirmed that these biomimetic composite coatings on Ti implants were essential for a significant enhancement of osseointegration of BC-coated Ti implants and bone regeneration. This research provides a novel strategy for the treatment of bone fractures with possible orthopedic applications.

1 January 2017 in The Knee
Verified
Journal Article
Open access
HBHorea Benea
Horea Benea
HDHenri D'AStorg
Henri D'AStorg
SKShahnaz Klouche
Shahnaz Klouche
TBThomas Karl Bauer
Thomas Karl Bauer
GTGheorghe Tomoaia
Gheorghe Tomoaia
PHPhilippe Hardy
Philippe Hardy

15 March 2018 in Revista de Chimie
Verified
Journal Article
Open access
HBHorea Rares Ciprian Benea
Horea Rares Ciprian Benea
KEKamel Earar
Kamel Earar
Wanda LattanziWanda Lattanzi
Wanda Lattanzi
VQVittorio Quercia
Vittorio Quercia
CBCristian Berce
Cristian Berce
AMAurel Mohan
Aurel Mohan

30 June 2023 in Studia Universitatis Babeș-Bolyai Chemia
Verified
Journal Article
Open access
DFDiana Alexandra Florea
Diana Alexandra Florea
AMAurora Mocanu
Aurora Mocanu
PCPop Lucian Cristian
Pop Lucian Cristian
GTGheorghe Tomoaia
Gheorghe Tomoaia
Cristina Teodora DobrotaCristina Teodora Dobrota
Cristina Teodora Dobrota
MTMaria Tomoaia-Cotisel
Maria Tomoaia-Cotisel
The use of toothpastes is the best way to combat enamel loss and degradation. When they also contain hydroxyapatite nanoparticles, HAP NPs, the tooth enamel can be restored by remineralization. In this study, we developed two types of toothpastes, one with nano sized HAP, noted P1, and the other with nano multi-substituted hydroxyapatite (ms-HAP, HAP-Mg-Zn-Si), noted P2, which were used to treat the artificially demineralized teeth enamel surface. The remineralization efficacy of the two toothpastes was determined on artificially created enamel lesions by suspending healthy enamel slices in demineralizing solution, made of orthophosphoric acid of 37.5% for 90 s. For this purpose, six extracted third molars were collected and twenty-four enamel slices were cut and arbitrarily allocated to the four groups, namely n = 6 enamel slices for each group. One group served as untreated (natural) enamel control, and another group comprised demineralized enamel and two test groups, firstly demineralized, and then, they were treated with toothpastes P1 and P2, respectively, each of them for ten days, and finally were noted P1 and P2 enamel surfaces. The surface morphology and roughness of all enamel specimens were studied by atomic force microscopy (AFM) before and after applying the treatment with the toothpastes. The toothpastes effect was evidenced by the average diameter of ceramic nanoparticles deposited within the superficial smooth layer on enamel surface having, at the completion of 10 days treatment, a low surface roughness close to that of natural enamel. This in vitro comparative study demonstrated that both toothpastes P1 and P2 can promote surface enamel repair by remineralization and the formation of a protective hydroxyapatite coating layer on the enamel surface treated with these toothpastes.

25 September 2023 in Studia Universitatis Babeș-Bolyai Chemia
Verified
Journal Article
Open access
AMAurora Mocanu
Aurora Mocanu
DFDiana Alexandra Florea
Diana Alexandra Florea
GTGheorghe Tomoaia
Gheorghe Tomoaia
PCPop Lucian Cristian
Pop Lucian Cristian
ADAncuta Danistean
Ancuta Danistean
MTMaria Tomoaia-Cotisel
Maria Tomoaia-Cotisel
A nanocomposite made from hydroxyapatite (HAP) and silver nanoparticles (AgNPs), namely HAP-4.5 wt% AgNPs, is reported. HAP was prepared using a wet precipitation technique, and AgNPs were made by reducing silver nitrate with glucose in basic medium. HAP, AgNPs and HAP-4.5 wt% AgNPs composite were characterized by X-ray diffraction (XRD), SEM - energy dispersive X-ray spectroscopy (EDS) and different imagistic methods: TEM and AFM. The antibacterial effect of the HAP-4.5 wt% AgNPs nanocomposite was tested using diffusion technique in nutritive agar on two pathogenic species, one Gram-negative (Salmonella typhimurium) and one Gram-positive (Bacillus cereus) and promising results were obtained. This hydroxyapatite-silver nanocomposite can be employed as a potential antimicrobial coating for dental and orthopedic implants, or they can be utilized such as bone cements in clinical procedures.