Rembuluwani Phillip Tshubwana

Mr. Rembuluwani Phillip Tshubwana


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VDVuyani Dladla
Vuyani Dladla
ANAgha Francis Nnachi
Agha Francis Nnachi
RTRembuluwani Phillip Tshubwana
Rembuluwani Phillip Tshubwana
The design of a compliant, safe, and reliable substation earth grid is not a straightforward process; in most cases, it requires some additional measures to be taken due to various constraints that differ from environment to environment, such as soil resistivity, a high fault level, a limited surface area, construction budget, etc. The IEEE Std 80-2013 proposes various refinement methods that can be applied to address different situations. For this study, the current limiting method, current diversion method, and touch and step voltage increment method were applied using the Electrical Transient Analysis Program (ETAP). A power system was designed, where a fault current generated by the supply transformers and back-fed by the power system’s motors was exported to the earth grid. Using this fault current, various simulations were conducted to assess the performance of the earth grid. The analysis results show that the application of the current limiting method using neutral earthing resistors has a great impact on the design of the earth grid as this method significantly reduces the fault current injected into the earth grid. Furthermore, by applying the current diversion method, the amount of fault current injected into the earth grid is reduced by a fair amount, which improves the performance of the earth grid. Lastly, increasing the tolerable limits of touch and step voltages by reducing the fault clearance times significantly improves the compliance of the earth grid as the clearance time is reduced. From this study, it is therefore concluded that, by implementing the refinement methods depending on the design requirements and feasibility of the application, one can improve the compliance state of an earth grid.

30 January 2024 in South African Journal of Science
Verified
Journal Article
Open access
PDF file
RTRembuluwani Phillip Tshubwana
Rembuluwani Phillip Tshubwana
CGChandima Gomes
Chandima Gomes
JCJohn Van Coller
John Van Coller
TRThierry Jean Claude Regnier
Thierry Jean Claude Regnier
Transmission line silicon rubber insulators are frequently subjected to harsh environmental conditions that can change their surface characteristics and result in a transient or permanent loss of hydrophobicity. Algae, fungi, mould, and lichen are examples of biological growth that can compromise the power system’s ability to operate safely by lowering the insulator’s flashover voltage. We evaluated and identified the major microorganisms that could be responsible for the flashovers of insulators in South Africa. Due to the difficulty of accessing insulators currently in use within the electricity network, only two insulators, from two provinces in South Africa, were used in the study. Although algae were not found on the insulators, two major filamentous fungi identified as Curvularia sp. and Aspergillus sp. were isolated. The absence of algae could be attributed to the weather pattern of the two locations where the insulators were placed during their use as part of the network. According to previous studies worldwide, the high occurrence of these fungi could be linked to the reduction of flashover voltage of the composite insulators. Although a larger survey including more insulators from all provinces in South Africa should be conducted, the current study demonstrates the need for a cleaning programme for insulators using cost-effective eco-friendly antimicrobial agents. Significance: Degradation and loss of hydrophobicity on the overhead line composite due to biological growth were found to be an impediment to the safe operation of high-voltage insulators. Fungi were found to be the main factor causing the degradation of overhead transmission lines. With these data, a model can be developed to predict the rate of biological growth on a given insulator, to estimate the degradation of the surface conditions with time for the utility to know when to remove them from the line. Such a model could lead to a more reliable and efficient power system and reduce the engineer’s workload.

28 September 2020
Verified
Conference Paper
Closed access
RTRembuluwani Phillip Tshubwana
Rembuluwani Phillip Tshubwana
CGChandima Gomes
Chandima Gomes
ANAgha Francis Nnachi
Agha Francis Nnachi
MKMahmood Mohammed Katun
Mahmood Mohammed Katun
Extreme environmental conditions can alter the surface properties of insulator surfaces, causing a temporary or permanent loss of hydrophobicity. Biological contamination such as algae, fungi, and lichen decrease the flashover performance of the insulator and this creates a potential threat to safe operation of the power systems. This biological contamination, which poses a major challenge in the operation of electrical power systems, decreases the flashover performance of the insulator and could result in complete failure thereof. The bio-films also possess the ability to retain water on the insulator surface, which results in increased leakage current levels under wet conditions. These leakage currents, caused by the biological contamination, are also considered to be one of the most severe problems regarding insulators in service, thus causing the formation of dry band arcing which could result in a flashover that could cause a power outage. This paper presents a consideration of some of the factors of climate parameters such as humidity, pollution, high temperature, ultraviolet exposition, sunlight, atmospheric pressure and biological degradation, which cause microorganisms in the air and microbial growth on insulator material surfaces.