The growing environmental challenge of electrical energy systems has prompted a substantial increase in renewable energy generation. Such generation systems allow for significant reduction of CO2 emissions compared with a traditional fossil fuel plant. Furthermore, several improvements in power systems network configuration and operation combined with new technologies have enabled reduction of losses and energy demand, thus contributing to reduction of CO2 emissions. Another environmental threat identified in electrical networks is the leaking of insulating sulfur hexafluoride (SF6) gas used in electrical gas insulated substations (GIS) and equipment. Because of its Global Warming Potential (GWP) of nearly 24,000 and its long life in the atmosphere (over 3000 years), SF6 gas was recognized as a greenhouse gas at the 1997 COP3; since then its use and emissions in the atmosphere have been regulated by international treaties. It is expected that as soon as an alternative insulating gas is found, SF6 use in high-voltage (HV) equipment will be banned. This paper presents an overview of the key research advances made in recent years in the quest to find eco-friendly gases to replace SF6. The review reports the main properties of candidate gases that are being investigated; in particular, natural gases (dry air, N2 or CO2) and polyfluorinated gases especially Trifluoroiodomethane (CF3I), Perfluorinated Ketones, Octafluorotetra-hydrofuran, Hydrofluoroolefin (HFOs), and Fluoronitriles are presented and their strengths and weaknesses are discussed with an emphasis on their dielectric properties (especially their dielectric strength), GWP, and boiling point with respect to the minimum operating temperature for HV power network applications.
A power transformer outage has a dramatic financial consequence not only for electric power systems utilities but also for interconnected customers. The service reliability of this important asset largely depends upon the condition of the oil-paper insulation. Therefore, by keeping the qualities of oil-paper insulation system in pristine condition, the maintenance planners can reduce the decline rate of internal faults. Accurate diagnostic methods for analyzing the condition of transformers are therefore essential. Currently, there are various electrical and physicochemical diagnostic techniques available for insulation condition monitoring of power transformers. This paper is aimed at the description, analysis and interpretation of modern physicochemical diagnostics techniques for assessing insulation condition in aged transformers. Since fields and laboratory experiences have shown that transformer oil contains about 70% of diagnostic information, the physicochemical analyses of oil samples can therefore be extremely useful in monitoring the condition of power transformers.
Synthetic esters have become more and more popular in last few decades, explaining the increasing number of units filled with this liquid year by year. They have been investigated under different aspects, both from the fundamental point of view and breakdown mechanisms, well as from the application point of view. However, their use in high voltage equipment is always a challenge and deeper knowledge of the various aspects that can be encountered in their exploitation is needed. The intent of this review paper is to present the recent research progress on synthetic ester liquid in relation to the selected issues, most important for ester development in the authors’ opinion. The described issues are the breakdown performance of synthetic esters, lightning impulse strength and pre-breakdown phenomena of synthetic esters, synthetic esters-based nanofluids, combined paper-synthetic ester based insulating systems, application of synthetic ester for retro-filling and drying of mineral oil-immersed transformers, DGA(dissolved gas analysis)-based diagnosis of synthetic esters filled transformers as well as static electrification of synthetic esters. The different sections are based both on the data available in the literature, but above all on the authors’ own experience from their research work on synthetic ester liquids for electrical application purposes.
This paper deals with a comparative study of AC and DC breakdown voltages of based mineral oil mixtures with natural and synthetic esters mainly used in high voltage power transformers. The goal was to analyze the performances of oil mixtures from the dielectric withstand point of view and to predict the behavior of transformers originally filled with mineral oil and re-filled with synthetic or natural ester oils when emptied for maintenance. The study concerns mixtures based on 20%, 50%, and 80% of natural and synthetic ester oils. AC breakdown voltages were measured using a sphere-sphere electrode system according to IEC 60156 specifications; the same specification was adopted for DC measurements since there is no standard specifications for this voltage waveform. A statistical analysis of the mean values, standard deviations, and histograms of breakdown voltage data was carried out. The Normal and Weibull distribution functions were used to analyze the experimental data and the best function that the data followed was used to estimate the breakdown voltage with risk of 1%, 10%, and 50% probability. It was shown that whatever the applied voltage waveforms, ester oils always have a significantly higher breakdown voltage than mineral oil. The addition of only 20% of natural or synthetic ester oil was sufficient to considerably increase the breakdown voltage of mineral oil. The dielectric strength of such a mixture is much higher than that of mineral oil alone and can reach that of ester oils. From the point of view of dielectric strength, the mixtures constitute an option for improving the performance of mineral oil. Thus, re-filling of transformers containing up to 20% mineral oil residues with ester oils, does not present any problem; it is even advantageous when considering only the breakdown voltage. Under AC, the mixtures with natural ester always follow the behavior of vegetable oil alone. With the exception of the 20% mixture of natural ester in DC, the breakdown voltage values of all the tested mixtures were in accordance with the normal distribution, which made it possible to define the breakdown voltages for the risk levels of 1%, 10%, and 50% of probability.
Power transformers play a critical role in electric power networks. Such transformers can suffer failures due to multiple stresses and aging. Thus, assessment of condition and diagnostic techniques are of great importance for improving power network reliability and service continuity. Several techniques are available to diagnose the faults within the power transformer. Frequency response analysis (FRA) method is a powerful technique for diagnosing transformer winding deformation and several other types of problems that are caused during manufacture, transportation, installation and/or service life. This paper provides a comprehensive review on FRA methods and their applications in diagnostics and fault identification for power transformers. The paper discusses theory and applications of FRA methods as well as various issues and challenges faced in the application of this method.
The problem of voltage collapse in power systems due to increased loads can be solved by adding renewable energy sources like wind and photovoltaic (PV) to some bus-bars. This option can reduce the cost of the generated energy and increase the system efficiency and reliability. In this paper, a modified smart technique using particle swarm optimization (PSO) has been introduced to select the hourly optimal load flow with renewable distributed generation (DG) integration under different operating conditions in the 30-bus IEEE system. Solar PV and wind power plants have been introduced to selected buses to evaluate theirs benefits as DG. Different solar radiation and wind speeds for the Dammam site in Saudi Arabia have been used as an example to study the feasibility of renewable energy integration and its effect on power system operation. Sensitivity analysis to the load and the other input data has been carried out to predict the sensitivity of the results to any deviation in the input data of the system. The obtained results from the proposed system prove that using of renewable energy sources as a DG reduces the generation and operation cost of the overall power system.