A power transformer outage has a dramatic financial consequence not only for electric power systems utilities but also for interconnected customers. The service reliability of this important asset largely depends upon the condition of the oil-paper insulation. Therefore, by keeping the qualities of oil-paper insulation system in pristine condition, the maintenance planners can reduce the decline rate of internal faults. Accurate diagnostic methods for analyzing the condition of transformers are therefore essential. Currently, there are various electrical and physicochemical diagnostic techniques available for insulation condition monitoring of power transformers. This paper is aimed at the description, analysis and interpretation of modern physicochemical diagnostics techniques for assessing insulation condition in aged transformers. Since fields and laboratory experiences have shown that transformer oil contains about 70% of diagnostic information, the physicochemical analyses of oil samples can therefore be extremely useful in monitoring the condition of power transformers.

8 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
Janvier Sylvestre N'choJanvier Sylvestre N'cho
Janvier Sylvestre N'cho
Issouf FofanaIssouf Fofana
Issouf Fofana
Diagnostic and condition monitoring of power transformers are key actions to guarantee their safe operation. The subsequent benefits include reduced service interruptions and economic losses associated with their unavailability. Conventional test methods developed for the condition assessment of power transformers have certain limitations. To overcome such problems, fiber optic-based sensors for monitoring the condition of transformers have been developed. Flawlessly built-up fiber optic-based sensors provide online and offline assessment of various parameters like temperature, moisture, partial discharges, gas analyses, vibration, winding deformation, and oil levels, which are based on different sensing principles. In this paper a variety and assessment of different fiber optic-based diagnostic techniques for monitoring power transformers are discussed. It includes significant tutorial elements as well as some analyses.

2 October 2012 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Janvier Sylvestre N'choJanvier Sylvestre N'cho
Janvier Sylvestre N'cho
Issouf FofanaIssouf Fofana
Issouf Fofana
ABA. Beroual
A. Beroual
TAT. Aka-Ngnui
T. Aka-Ngnui
JSJ. Sabau
J. Sabau
Lifetime extension of power transformers is a subject of high importance for electric power systems utilities. The decision of replacing, refurbishing or repairing a service aged power transformer requires considering several factors, especially the cost and time to execute the work. The lifetime of the power transformer being related to the condition of the insulation system; one way of improving the situation is to reclaim insulating oil by Fuller's Earth treatment. This procedure is economically attractive because of increasing prices for both mineral and synthetic transformer coolants, effective cost and environmentally sounds. Reclamation rejuvenates the transformer oil by eliminating contaminants. In this paper, a series of experiments has been performed with service aged oils reclaimed in laboratory conditions. Fast, inexpensive and reliable laboratory testing procedures developed by ASTM (D 6802 and D6181) were also used to monitor decay products as traces impurities. The results obtained in laboratory conditions, indicate that a large number of reclamation passes (around 15 passes) are required to regenerate inservice aged oil to a grade close to new oil. It is also shown that not only the reclamation improves the gassing tendency of oil, but also the type of Fuller's Earth is very important for reclamation process. By upgrading the analytical chemistry of oil, the predictive maintenance of this non-renewable resource is modernized, its cost diminished and the service reliability of transformers enhanced. Currently, Fuller's Earth is only used once. After depletion it must be disposed of in a land fill. By using two organic solvents that are recoverable by atmospheric distillation, it is shown, in laboratory conditions, that this mineral absorbent can be reactivated and successfully reused many times.

10 October 2011 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Janvier Sylvestre N'choJanvier Sylvestre N'cho
Janvier Sylvestre N'cho
Issouf FofanaIssouf Fofana
Issouf Fofana
ABA. Beroual
A. Beroual
TAT. Aka-Ngnui
T. Aka-Ngnui
JSJ. Sabau
J. Sabau
Since gas evolvement deteriorates the dielectrical properties of insulating fluid, its ability to resist decomposition under electrical discharge is of paramount importance for the safety of power transformers under operating conditions. In this paper, a series of experiments have been performed under electrical discharge according to ASTM D6180. Various insulating fluids were considered. The samples include minerals oils, synthetic and natural esters, and silicone fluid. The results indicate that the gassing tendency of natural esters is much lower than their counterparts. No significant differences between synthetic esters and silicone fluid were observed. Severely hydrotreated and hydrocracked oils indicate a higher gassing tendency. It is also shown that service-aged oil gassing tendency decreases with reclamation passes. The reclamation of service aged oil by three commercially available Fuller's Earth (FE) showed a declined gassing tendency when FE helped reducing the DDF and turbidity. In addition, the theoretical premises that, oil born decay products contribute to the oil gassing, is experimentally confirmed under laboratory conditions. Extended stability test (3 times longer than the standard specification) also provide convincing evidences that each brand of mineral insulating oil might contain a limited amount of unstable hydrocarbons and volatile compounds. This finding indicates that when in service conditions these are gradually decomposed, the gassing tendency should go down.

6 August 2020 in IEEE Access
Verified
Journal Article
Open access
MUMOHAN RAO UNGARALA
MOHAN RAO UNGARALA
Issouf FofanaIssouf Fofana
Issouf Fofana
Janvier Sylvestre N'choJanvier Sylvestre N'cho
Janvier Sylvestre N'cho
From the recent past, biodegradable dielectric fluids are becoming popular across the global utilities for use in oil-filled transformers. To date, several utilities have started using biodegradable insulating fluids for new and retro-filled power and distribution transformers. The intent of this article is to compare and analyze various aspects that are involved in the successful operation and maintenance of mineral oil and ester filled transformers. The comparative analysis in this article is aimed at properties, condition monitoring, diagnostic, and reclamation aspects of ester filled transformers. The imperative and pertinent standards, including IEEE Std C57.106, IEEE Std C57.104, IEEE Std 637, IEEE Std C57.147, and IEEE Std C57.155 remain the target objectives for potential analysis. It is hoped that this critical analysis will be useful for utility and condition monitoring engineers in understanding several key aspects of ester fluids vis-à-vis traditional insulating fluids. The present analysis might also be useful for researchers and industry interested in alternative dielectric fluids for transformer insulation technology.

1 August 2011
Verified
Conference Paper
Closed access
Issouf FofanaIssouf Fofana
Issouf Fofana
Janvier Sylvestre N'choJanvier Sylvestre N'cho
Janvier Sylvestre N'cho
JOJ. C. Olivares-Galvan
J. C. Olivares-Galvan
RER. Escarela-Perez
R. Escarela-Perez
Pavlos GeorgilakisPavlos Georgilakis
Pavlos Georgilakis
The growing demands for improved fire safety, source material sustainability, environment friendliness, and asset life extension have driven the research and development efforts of natural/synthetic esters, less-flammable fluids. This contribution reports some investigations on commercially available ester fluids. Many comparisons are made to the quality test results of mineral oil, as this is something we are all familiar with. The stability under electrical stress and the stability to aging of the insulating fluids were investigated. The gassing performance characteristics of natural ester fluids are far superior to those of conventional mineral oil. A significant reduction in insulation aging rate was observed with synthetic ester fluids.