Yulie Wu

Dr. Yulie Wu


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2011 in Sensors
Verified
Journal Article
Open access
PDF file
YWYulie Wu
Yulie Wu
XXXi Xiang
Xi Xiang
YTYi Tao
Yi Tao
XWXiaomei Wu
Xiaomei Wu
XWXuezhong Wu
Xuezhong Wu
The zero bias stability, which is an important performance parameter for vibratory cylinder gyroscopes, is high sensitive to temperature change. It is considered that the varying temperature makes the vibration mode axes unstable, which has significant influence on the zero bias stability. This paper will investigate this problem in detail. First, the relationships between the angular positions of vibration mode axes and the zero bias are analyzed. Secondly, the thermal-modal model of the cylinder resonator with several defects such as mass imbalance, frequency split (FS), and geometry errors are developed by ANSYS. Simulation results show that with the increase of temperature, angular positions of the vibration mode axes obviously change, which leads to a dramatic zero bias drift. Finally, several major influence factors on the angular position stability of vibration mode axes, including frequency split, geometry errors, thermal elastic modulus coefficient (TEMC) and thermal expansion coefficient (TEC) are analyzed in detail. Simulation results in this paper will be helpful for deep understanding of the drift principle of zero bias induced by temperature for vibratory cylinder gyroscopes and also be helpful for further temperature compensation or control.

16 January 2015 in Sensors
Verified
Journal Article
Open access
PDF file
ZYZhang Yongmeng
Zhang Yongmeng
YWYulie Wu
Yulie Wu
XWXuezhong Wu
Xuezhong Wu
XXXi Xiang
Xi Xiang
JWJianqiu Wang
Jianqiu Wang
Non-contact testing is an important method for the study of the vibrating characteristic of cylindrical resonators. For the vibratory cylinder gyroscope excited by piezo-electric electrodes, mode testing of the cylindrical resonator is difficult. In this paper, a novel vibration testing method for cylindrical resonators is proposed. This method uses a MEMS microphone, which has the characteristics of small size and accurate directivity, to measure the vibration of the cylindrical resonator. A testing system was established, then the system was used to measure the vibration mode of the resonator. The experimental results show that the orientation resolution of the node of the vibration mode is better than 0.1°. This method also has the advantages of low cost and easy operation. It can be used in vibration testing and provide accurate results, which is important for the study of the vibration mode and thermal stability of vibratory cylindrical gyroscopes.

30 March 2016 in Journal of Central South University
Verified
Journal Article
Closed access
PDF file
XZXin Zhou
Xin Zhou
YWYulie Wu
Yulie Wu
XWXue-Zhong Wu
Xue-Zhong Wu
YZYong-Meng Zhang
Yong-Meng Zhang
YZYu Zheng
Yu Zheng

8 November 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
JPJunji Pu
Junji Pu
KZKai Zeng
Kai Zeng
YWYulie Wu
Yulie Wu
DXDingbang Xiao
Dingbang Xiao
In recent years, the optical accelerometer based on the optical trapping force effect has gradually attracted the attention of researchers for its high sensitivity and high measurement accuracy. However, due to its large size and the complexity of optical path adjustment, the optical force accelerometers reported are only suitable for the laboratory environment up to now. In this paper, a miniature optical force dual-axis accelerometer based on the miniature optical system and a particles cavity which is prepared by Micro-Electro-Mechanical Systems (MEMS) technology is proposed. The overall system of the miniature optical levitation including the miniature optical system and MEMS particles cavity is a cylindrical structure with a diameter of about 10 mm and a height of 33 mm (Φ 10 mm × 33 mm). Moreover, the size of this accelerometer is 200 mm × 100 mm × 100 mm. Due to the selected light source being a laser diode light source with elliptical distribution, it is sensitive to the external acceleration in both the long axis and the short axis. This accelerometer achieves a measurement range of ±0.17 g–±0.26 g and measurement resolution of 0.49 mg and 1.88 mg. The result shows that the short-term zero-bias stability of the two orthogonal axes of the optical force accelerometer is 4.4 mg and 9.2 mg, respectively. The main conclusion that can be drawn is that this optical force accelerometer could provide an effective solution for measuring acceleration with an optical force effect for compact engineering devices.

30 July 2016 in Sensors
Verified
Journal Article
Open access
PDF file
ZWZidan Wang
Zidan Wang
YWYulie Wu
Yulie Wu
XXXi Xiang
Xi Xiang
ZYZhang Yongmeng
Zhang Yongmeng
XWXuezhong Wu
Xuezhong Wu
For cylindrical shell gyroscopes, node position of their operating eigenmodes has an important influence on the gyroscopes’ performance. It is considered that the nodes are equally separated from each other by 90° when the resonator vibrates in the standing wave eigenmode. However, we found that, due to manufacturing errors and trimming, the nodes may not be equally distributed. This paper mainly analyzes the influences of unbalanced masses on the cylindrical resonators’ node position, by using FEM simulation and experimental measurement.

4 May 2017 in Sensors
Verified
Journal Article
Open access
PDF file
JSJiangkun Sun
Jiangkun Sun
YWYulie Wu
Yulie Wu
XXXi Xiang
Xi Xiang
ZYZhang Yongmeng
Zhang Yongmeng
XWXuezhong Wu
Xuezhong Wu
The cylindrical resonator gyroscope (CRG) is a typical Coriolis vibratory gyroscope whose performance is mostly influenced by the damping characteristic of the cylindrical resonator. However, the tremendous damping influences caused by pasting piezoelectric electrodes on the gyroscope, which degrades the performance to a large extent, have rarely been studied. In this paper, the dynamical model is established to analyze various forms of energy consumption. In addition, a FE COMSOL model is also created to discuss the damping influences of several significant parameters of the adhesive layer and piezoelectric electrodes, respectively, and then explicit influence laws are obtained. Simulation results demonstrate that the adhesive layer has some impact on the damping characteristic, but it not significant. The Q factor decreases about 30.31% in total as a result of pasting piezoelectric electrodes. What is more, it is discovered that piezoelectric electrodes with short length, locations away from the outside edges, proper width and well-chosen thickness are able to reduce the damping influences to a large extent. Afterwards, experiments of testing the Q factor are set up to validate the simulation values.