bocheng ding

Dr. bocheng ding


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BDbocheng ding
bocheng ding
WXWeiqing Xu
Weiqing Xu
RWRuichang Wu
Ruichang Wu
YFYunfei Feng
Yunfei Feng
LTLifang Tian
Lifang Tian
XLXiao-Jing Liu
Xiao-Jing Liu
Velocity map imaging (VMI) spectrometry is widely used to measure the momentum distribution of charged particles with the kinetic energy of a few tens of electronVolts. With the progress of femtosecond laser and X-ray free-electron laser, it becomes increasingly important to extend the electron kinetic energy to 1 keV. Here, we report on a recently built composite VMI spectrometer at the Shanghai soft X-ray free-electron laser, which can measure ion images and high-energy electron images simultaneously. In the SIMION simulation, we extended the electron kinetic energy to 1 keV with a resolution <2% while measuring the ions with the kinetic energy of 20 eV. The experimental performance is tested by measuring Ar 2p photoelectron spectra at Shanghai Synchrotron Radiation Facility, and O+ kinetic energy spectrum from dissociative ionization of O2 by 800 nm femtosecond laser. We reached a resolution of 1.5% at the electron kinetic energy of 500 eV. When the electron arm is set for 100 eV, a resolution of 4% is reached at the ion kinetic energy of 5.6 eV. This composite VMI spectrometer will support the experiment, such as X-ray multi-photon excitation/ionization, Auger electrons emission, attosecond streaking.

6 March 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YFYunfei Feng
Yunfei Feng
BDbocheng ding
bocheng ding
RWRuichang Wu
Ruichang Wu
JXJin Xin
Jin Xin
KWKefei Wu
Kefei Wu
XLXiao-Jing Liu
Xiao-Jing Liu
The velocity map imaging (VMI) technique is used to acquire the momentum distribution of charged particles. Here, we introduce two additional operation modes for our recently built velocity map imaging (VMI) spectrometer: the spatial mapping mode that magnifies the image of zero energy ions with different scales and the high-resolution momentum mapping mode that acquires the electron momentum distribution at the kinetic energy of about 100 eV. In simulations, the ion image is magnified with a factor of up to 7.6, and a relative resolution of 0.15% at 150 eV electron kinetic energy is predicted. Switching between these two modes helps reduce the alignment error to below 0.2 mm. In the test using the above-threshold ionization (ATI) of argon (Ar), the Ar+ ion image is magnified by a factor of up to 6.7, and a relative resolution of 1.3% at 44.6 eV electron kinetic energy is achieved.