The Bonny Method of Guided Imagery and Music uses music and imagery to access and explore personal emotions associated with episodic memories. Understanding the neural mechanism of guided imagery and music (GIM) as combined stimuli for emotional processing informs clinical application. We performed functional magnetic resonance imaging (fMRI) to demonstrate neural mechanisms of GIM for negative emotional processing when personal episodic memory is recalled and re-experienced through GIM processes. Twenty-four healthy volunteers participated in the study, which used classical music and verbal instruction stimuli to evoke negative emotions. To analyze the neural mechanism, activated regions associated with negative emotional and episodic memory processing were extracted by conducting volume analyses for the contrast between GIM and guided imagery (GI) or music (M). The GIM stimuli showed increased activation over the M-only stimuli in five neural regions associated with negative emotional and episodic memory processing, including the left amygdala, left anterior cingulate gyrus, left insula, bilateral culmen, and left angular gyrus (AG). Compared with GI alone, GIM showed increased activation in three regions associated with episodic memory processing in the emotional context, including the right posterior cingulate gyrus, bilateral parahippocampal gyrus, and AG. No neural regions related to negative emotional and episodic memory processing showed more activation for M and GI than for GIM. As a combined multimodal stimulus, GIM may increase neural activations related to negative emotions and episodic memory processing. Findings suggest a neural basis for GIM with personal episodic memories affecting cortical and subcortical structures and functions.
Recent advances in deep learning have contributed greatly to the field of parallel MR imaging, where a reduced amount of k-space data are acquired to accelerate imaging time. In our previous work, we have proposed a deep learning method to reconstruct MR images directly from k-space data acquired with Cartesian trajectories. However, MRI utilizes various non-Cartesian trajectories, such as radial trajectories, with various numbers of multi-channel RF coils according to the purpose of an MRI scan. Thus, it is important for a reconstruction network to efficiently unfold aliasing artifacts due to undersampling and to combine multi-channel k-space data into single-channel data. In this work, a neural network named ‘ETER-net’ is utilized to reconstruct an MR image directly from k-space data acquired with Cartesian and non-Cartesian trajectories and multi-channel RF coils. In the proposed image reconstruction network, the domain transform network converts k-space data into a rough image, which is then refined in the following network to reconstruct a final image. We also analyze loss functions including adversarial and perceptual losses to improve the network performance. For experiments, we acquired k-space data at a 3T MRI scanner with Cartesian and radial trajectories to show the learning mechanism of the direct mapping relationship between the k-space and the corresponding image by the proposed network and to demonstrate the practical applications. According to our experiments, the proposed method showed satisfactory performance in reconstructing images from undersampled single- or multi-channel k-space data with reduced image artifacts. In conclusion, the proposed method is a deep-learning-based MR reconstruction network, which can be used as a unified solution for parallel MRI, where k-space data are acquired with various scanning trajectories.
Improvements in transmission and reception sensitivities of radiofrequency (RF) coils used in ultra-high field (UHF) magnetic resonance imaging (MRI) are needed to reduce specific absorption rates (SAR) and RF power deposition, albeit without applying high-power RF. Here, we propose a method to simultaneously improve transmission efficiency and reception sensitivity of a band-pass birdcage RF coil (BP-BC RF coil) by combining a multi-channel wireless RF element (MCWE) with a high permittivity material (HPM) in a 7.0 T MRI. Electromagnetic field (EM-field) simulations, performed using two types of phantoms, viz., a cylindrical phantom filled with oil and a human head model, were used to compare the effects of MCWE and HPM on BP-BC RF coils. EM-fields were calculated using the finite difference time-domain (FDTD) method and analyzed using Matlab software. Next, to improve RF transmission efficiency, we compared two HPM structures, namely, a hollow cylinder shape HPM (hcHPM) and segmented cylinder shape HPM (scHPM). The scHPM and MCWE model comprised 16 elements (16-rad BP-BC RF coil) and this coil configuration demonstrated superior RF transmission efficiency and reception sensitivity along with an acceptable SAR. We expect wider clinical application of this combination in 7.0 T MRIs, which were recently approved by the United States Food and Drug Administration.
3 February 2024 in Computers in Biology and Medicine
Medical images are acquired through diverse imaging systems, with each system employing specific image reconstruction techniques to transform sensor data into images. In MRI, sensor data (i.e., k-space data) is encoded in the frequency domain, and fully sampled k-space data is transformed into an image using the inverse Fourier Transform. However, in efforts to reduce acquisition time, k-space is often subsampled, necessitating a sophisticated image reconstruction method beyond a simple transform. The proposed approach addresses this challenge by training a model to learn domain transform, generating the final image directly from undersampled k-space input. Significantly, to improve the stability of reconstruction from randomly subsampled k-space data, folded images are incorporated as supplementary inputs in the dual-input ETER-net. Moreover, modifications are made to the formation of inputs for the bi-RNN stages to accommodate non-fixed k-space trajectories. Experimental validation, encompassing both regular and irregular sampling trajectories, validates the method's effectiveness. The results demonstrated superior performance, measured by PSNR, SSIM, and VIF, across acceleration factors of 4 and 8. In summary, the dual-input ETER-net emerges as an effective both regular and irregular sampling trajectories, and accommodating diverse acceleration factors.
It is challenging to extract the brain region from T2-weighted magnetic resonance infant brain images because conventional brain segmentation algorithms are generally optimized for adult brain images, which have different spatial resolution, dynamic changes of imaging intensity, brain size and shape from infant brain images. In this study, we propose a brain extraction algorithm for infant T2-weighted images. The proposed method utilizes histogram partitioning to separate brain regions from the background image. Then, fuzzy c-means thresholding is performed to obtain a rough brain mask for each image slice, followed by refinement steps. For slices that contain eye regions, an additional eye removal algorithm is proposed to eliminate eyes from the brain mask. By using the proposed method, accurate masks for infant T2-weighted brain images can be generated. For validation, we applied the proposed algorithm and conventional methods to T2 infant images (0–24 months of age) acquired with 2D and 3D sequences at 3T MRI. The Dice coefficients and Precision scores, which were calculated as quantitative measures, showed the highest values for the proposed method as follows: For images acquired with a 2D imaging sequence, the average Dice coefficients were 0.9650 ± 0.006 for the proposed method, 0.9262 ± 0.006 for iBEAT, and 0.9490 ± 0.006 for BET. For the data acquired with a 3D imaging sequence, the average Dice coefficient was 0.9746 ± 0.008 for the proposed method, 0.9448 ± 0.004 for iBEAT, and 0.9622 ± 0.01 for BET. The average Precision was 0.9638 ± 0.009 and 0.9565 ± 0.016 for the proposed method, 0.8981 ± 0.01 and 0.8968 ± 0.008 for iBEAT, and 0.9346 ± 0.014 and 0.9282 ± 0.019 for BET for images acquired with 2D and 3D imaging sequences, respectively, demonstrating that the proposed method could be efficiently used for brain extraction in T2-weighted infant images.
Magnetic resonance imaging (MRI) is a powerful medical imaging technique used for acquiring high-resolution anatomical and functional images of the human body. With the development of an 11.74 Tesla (T) human MRI system at our facility, we are designing novel radiofrequency (RF) coils optimized for brain imaging at ultra-high fields. To meet specific absorption rate (SAR) safety limits, this study focuses on localized imaging of individual brain lobes rather than whole-brain array designs. Conventional loop coils, while widely used, offer limited |B1|-field uniformity at 500 MHz—the Larmor frequency at 11.74 T, which can reduce image quality. Therefore, it is important to develop antennas and coils for highly uniform fields. As an alternative, we propose an elliptical microstrip design, which combines the compact resonant properties of microstrips with the enhanced field coverage provided by loop geometry. We simulated a three-element elliptical microstrip array and compared its performance with a conventional loop coil. The proposed design demonstrated improved magnetic field uniformity and coverage across targeted brain regions. Preliminary bench-top validation confirmed the feasibility of resonance tuning at 500 MHz, supporting its potential for future high-field MRI applications.