24 February 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
JWJun Yeon Won
Jun Yeon Won
HPHaewook Park
Haewook Park
SLSeungeun Lee
Seungeun Lee
JSJeong-Whan Son
Jeong-Whan Son
YCYina Chung
Yina Chung
Jae Sung LeeJae Sung Lee
Jae Sung Lee
In study, we developed a positron emission tomography (PET) insert for simultaneous brain imaging within 7-Tesla (7T) magnetic resonance (MR) imaging scanners. The PET insert has 18 sectors, and each sector is assembled with two-layer depth-of-interaction (DOI)-capable high-resolution block detectors. The PET scanner features a 16.7-cm-long axial field-of-view (FOV) to provide entire human brain images without bed movement. The PET scanner early digitizes a large number of block detector signals at a front-end data acquisition (DAQ) board using a novel field-programmable gate array (FPGA)-only signal digitization method. All the digitized PET data from the front-end DAQ boards are transferred using gigabit transceivers via non-magnetic high-definition multimedia interface (HDMI) cables. A back-end DAQ system provides a common clock and synchronization signal for FPGAs over the HDMI cables. An active cooling system using copper heat pipes is applied for thermal regulation. All the 2.17-mm-pitch crystals with two-layer DOI information were clearly identified in the block detectors, exhibiting a system-level energy resolution of 12.6%. The PET scanner yielded clear hot-rod and Hoffman brain phantom images and demonstrated 3D PET imaging capability without bed movement. We also performed a pilot simultaneous PET/MR imaging study of a brain phantom. The PET scanner achieved a spatial resolution of 2.5 mm at the center FOV (NU 4) and a sensitivity of 18.9 kcps/MBq (NU 2) and 6.19% (NU 4) in accordance with the National Electrical Manufacturers Association (NEMA) standards.

5 July 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KKKyoung-Nam Kim
Kyoung-Nam Kim
DHDaniel Hernandez
Daniel Hernandez
JSJeung-Hoon Seo
Jeung-Hoon Seo
YNYoung Noh
Young Noh
YHYeji Han
Yeji Han
JCJun-Young Chung
Jun-Young Chung
The neuroimaging of humans using 7T magnetic resonance imaging (MRI) has been conducted using phased array (PA) coils with different numbers of receiving channels. PA coils with a high number of channels may offer parallel imaging (PI) with a high reduction (R)-factor, which is enabled via under-sampling and coil geometry (g) factor, increasing the radiofrequency signal sensitivity provided by a small coil. The goals of this study were to assess and validate the coil performance of PA coils with different numbers of receiver (Rx)-channels in and to propose the coil selection guidelines by visualizing 7T brain images. The combined magnetic flux density (||B1||) distributions of four configurations of PA coils—4-, 8-, 12-, and 16-channel Rx-only mode under the local transmit (Tx) mode of birdcage coils—were evaluated using electromagnetic (EM) calculations. These four configurations of PA coils and a local Tx coil were designed and built for a 7T MRI experiment. For 7T brain imaging experiments, all PA coils with (w/) and without (w/o) R-factors were compared in terms of signal-to-noise ratio (SNR) and spatial noise variation (SNV). EM simulation results clearly demonstrated that PA coils with a high number of Rx channels showed more homogeneously distributed ||B1|| fields than a PA coils with a low number of Rx coils. The results of this study demonstrate that a collection of smaller surface coils can contribute to high RF signal sensitivity in terms of the anatomical coverage of the brain and may facilitate PI. With further improvement in coil technology, researchers and clinicians will be provided with PA coils with different numbers of channels, which can ensure the optimum SNR and PI benefits for 7T brain MR imaging.

3 December 2020 in NMR in Biomedicine
Verified
Journal Article
Open access
PDF file
SKSang‐Young Kim
Sang‐Young Kim
JSJunghyun Song
Junghyun Song
JYJong‐Hyun Yoon
Jong‐Hyun Yoon
KKKyoung‐Nam Kim
Kyoung‐Nam Kim
JCJun-Young Chung
Jun-Young Chung
YNYoung Noh
Young Noh
Sodium is crucial for the maintenance of cell physiology, and its regulation of the sodium‐potassium pump has implications for various neurological conditions. The distribution of sodium concentrations in tissue can be quantitatively evaluated by means of sodium MRI (23Na‐MRI). Despite its usefulness in diagnosing particular disease conditions, tissue sodium concentration (TSC) estimated from 23Na‐MRI can be strongly biased by partial volume effects (PVEs) that are induced by broad point spread functions (PSFs) as well as tissue fraction effects. In this work, we aimed to propose a robust voxel‐wise partial volume correction (PVC) method for 23Na‐MRI. The method is based on a linear regression (LR) approach to correct for tissue fraction effects, but it utilizes a 3D kernel combined with a modified least trimmed square (3D‐mLTS) method in order to minimize regression‐induced inherent smoothing effects. We acquired 23Na‐MRI data with conventional Cartesian sampling at 7 T, and spill‐over effects due to the PSF were considered prior to correcting for tissue fraction effects using 3D‐mLTS. In the simulation, we found that the TSCs of gray matter (GM) and white matter (WM) were underestimated by 20% and 11% respectively without correcting tissue fraction effects, but the differences between ground truth and PVE‐corrected data after the PVC using the 3D‐mLTS method were only approximately 0.6% and 0.4% for GM and WM, respectively. The capability of the 3D‐mLTS method was further demonstrated with in vivo 23Na‐MRI data, showing significantly lower regression errors (ie root mean squared error) as compared with conventional LR methods (p < 0.001). The results of simulation and in vivo experiments revealed that 3D‐mLTS is superior for determining under‐ or overestimated TSCs while preserving anatomical details. This suggests that the 3D‐mLTS method is well suited for the accurate determination of TSC, especially in small focal lesions associated with pathological conditions.

1 April 2014 in Neuroscience Research
Verified
Journal Article
Closed access
SOSung Suk Oh
Sung Suk Oh
YHYeji Han
Yeji Han
JLJongho Lee
Jongho Lee
SYSeong Dae Yun
Seong Dae Yun
JKJoong Koo Kang
Joong Koo Kang
HPHyunWook Park
HyunWook Park

15 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JSJeunghoon Seo
Jeunghoon Seo
JCJun-Young Chung
Jun-Young Chung
Magnetic resonance imaging (MRI) systems must undergo quantitative evaluation through daily and periodic performance assessments. In general, the reference or standard radiofrequency (RF) coils for these performance assessments of 1.5 to 7.0 T MRI systems have been low-pass-type birdcage (LP-BC) RF coils. However, LP-BC RF coils are inappropriate for use as reference RF coils because of their relatively lower magnetic field (B1-field) sensitivity than other types of BC RF coils, especially in ultrahigh-field (UHF) MRI systems above 3.0 T. Herein, we propose a hybrid-type BC (Hybrid-BC) RF coil as a reference RF coil with improved B1-field sensitivity in UHF MRI system and applied it to an 11.7 T MRI system. An electromagnetic field (EM-field) analysis on the Hybrid-BC RF coil was performed to provide the proper dimensions for its use as a reference RF coil. Commercial finite difference time-domain program was used in EM-field simulation, and home-made analysis programs were used in analysis. The optimal specifications of the proposed Hybrid-BC RF coils for them to qualify as reference RF coils are proposed based on their B1+-field sensitivity under unnormalized conditions, as well as by considering their B1+-field uniformity and RF safety under normalized conditions.

26 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
COChangheun Oh
Changheun Oh
JCJun-Young Chung
Jun-Young Chung
YHYeji Han
Yeji Han
Recent advances in deep learning have contributed greatly to the field of parallel MR imaging, where a reduced amount of k-space data are acquired to accelerate imaging time. In our previous work, we have proposed a deep learning method to reconstruct MR images directly from k-space data acquired with Cartesian trajectories. However, MRI utilizes various non-Cartesian trajectories, such as radial trajectories, with various numbers of multi-channel RF coils according to the purpose of an MRI scan. Thus, it is important for a reconstruction network to efficiently unfold aliasing artifacts due to undersampling and to combine multi-channel k-space data into single-channel data. In this work, a neural network named ‘ETER-net’ is utilized to reconstruct an MR image directly from k-space data acquired with Cartesian and non-Cartesian trajectories and multi-channel RF coils. In the proposed image reconstruction network, the domain transform network converts k-space data into a rough image, which is then refined in the following network to reconstruct a final image. We also analyze loss functions including adversarial and perceptual losses to improve the network performance. For experiments, we acquired k-space data at a 3T MRI scanner with Cartesian and radial trajectories to show the learning mechanism of the direct mapping relationship between the k-space and the corresponding image by the proposed network and to demonstrate the practical applications. According to our experiments, the proposed method showed satisfactory performance in reconstructing images from undersampled single- or multi-channel k-space data with reduced image artifacts. In conclusion, the proposed method is a deep-learning-based MR reconstruction network, which can be used as a unified solution for parallel MRI, where k-space data are acquired with various scanning trajectories.