Christian Walter

Christian Walter


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2017 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
UHUlf Krister Hofmann
Ulf Krister Hofmann
RKRamona Luise Keller
Ramona Luise Keller
CWChristian Walter
Christian Walter
FMFalk Mittag
Falk Mittag
Imaging results are frequently considered as hallmarks of disease by spine surgeons to plan their future treatment strategy. Numerous classification systems have been proposed to quantify or grade lumbar magnetic resonance imaging (MRI) scans and thus objectify imaging findings. The clinical impact of the measured parameters remains, however, unclear. To evaluate the pathological significance of imaging findings in patients with multisegmental degenerative findings, clinicians can perform image-guided local infiltrations to target defined areas such as the facet joints. The aim of the present retrospective study was to evaluate the correlation of MRI facet joint degeneration and spinal stenosis measurements with improvement obtained by image-guided intraarticular facet joint infiltration. Fifty MRI scans of patients with chronic lumbar back pain were graded radiologically using a wide range of classification and measurement systems. The reported effect of facet joint injections at the site was recorded, and a comparative analysis performed. When we allocated patients according to their reported pain relief, 27 showed no improvement (0–30%), 16 reported good improvement (31–75%) and 7 reported excellent improvement (> 75%). MRI features assessed in this study did, however, not show any relevant correlation with reported pain after facet joint infiltration: Values for Kendall’s tau ranged from τ = − 0.190 for neuroforaminal stenosis grading as suggested by Lee, to τ = 0.133 for posterior disc height as proposed by Hasegawa. Despite the trend in evidence-based medicine to provide medical algorithms, our findings underline the continuing need for individualised spine care that, along with imaging techniques or targeted infiltrations, includes diagnostic dimensions such as good patient history and clinical examination to formulate a diagnosis. ClinicalTrials.gov , NCT03308149 , retrospectively registered October 2017

17 July 2020 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
CWChristian Walter
Christian Walter
SSSaskia Sachsenmaier
Saskia Sachsenmaier
MWMarkus Wünschel
Markus Wünschel
MTMartin Teufel
Martin Teufel
MGMarco Götze
Marco Götze
Background: Clubfoot is one of the most prevalent musculoskeletal congenital defects. Gold standard treatment of idiopathic clubfoot is the conservative Ponseti method, including the reduction of deformity with weekly serial plaster casting and percutaneous Achilles tenotomy. It is well known that parents of children with severe and chronic illnesses are mentally stressed, but in recent studies regarding clubfoot treatment, parents were only asked about their satisfaction with the treatment. Largely unknown is parental distress before and during plaster casting in clubfoot.Therefore, we want to determinate first, how pronounced the parents’ worries are before treatment and if they decrease during the therapy. Second, we hypothesized that parents faced with an extreme deformity (high Pirani score), reveal more distress, than parents whose children have a less pronounced deformity (low Pirani score). Therefore, we wanted to investigate whether the Pirani score correlates with the parents’ mental resilience in relation to the therapy of the child as a global distress parameter.Methods: To answer this question, we developed a questionnaire with the following emphases: Physical capacity, mental resilience, motion score, parents score, and child score with point scores 1 (not affected) to 6 (high affected). Subsequently, we interviewed 20 parents whose children were treated with clubfeet and determined the Pirani score of the infants at the beginning (T0) and at the end (TE) of the treatment with plaster casting.Results: High values were obtained in child score (Mean (M) = 3.11), motion score (M= 2.63), and mental resilience (M= 2.25). During treatment, mental resilience improved (p= 0.015) significantly. Spearman correlation coefficient between Pirani score (T0) and mental resilience (T0) is 0.21, so the initial hypothesis had to be rejected.Conclusion: The issues of the children are in the focus of parental worries concerning clubfoot treatment, especially the assumed future motion and the assumed ability to play with other children. Particular emphasis should be placed on educating parents about the excellent long-term results in the function of the treated feet especially as this topic shows the greatest parental distress.

9 August 2018 in Journal of Tissue Engineering and Regenerative Medicine
Verified
Journal Article
Closed access
PDF file
UHUlf Krister Hofmann
Ulf Krister Hofmann
JSJessica Steidle
Jessica Steidle
MDMarina Danalache
Marina Danalache
FBFlorian Bonnaire
Florian Bonnaire
CWChristian Walter
Christian Walter
Bernd RolauffsBernd Rolauffs
Bernd Rolauffs

31 January 2013 in Medical Engineering & Physics
Verified
Journal Article
Closed access
CWChristian Walter
Christian Walter
ULUlf Leichtle
Ulf Leichtle
ALAndrea Lorenz
Andrea Lorenz
FMFalk Mittag
Falk Mittag
NWNikolaus Wülker
Nikolaus Wülker
SRStephan Rothstock
Stephan Rothstock
Several quantitative methods for the in vitro characterization of cartilage quality are available. However, only a few of these methods allow surgical cartilage manipulations and the subsequent analysis of the friction properties of complete joints. This study introduces an alternative approach to the characterization of the friction properties of entire joint surfaces using the dissipated energy during motion of the joint surfaces. Seven sheep wrist joints obtained post mortem were proximally and distally fixed to a material testing machine. With the exception of the carpometacarpal articulation surface, all joint articulations were fixed with 'Kirschner' wires. Three cartilage defects were simulated with a surgically introduced groove (16 mm(2), 32 mm(2), 300 mm(2)) and compared to intact cartilage without an artificial defect. The mean dissipated energy per cycle was calculated from the hysteresis curve during ten torsional motion cycles (±10°) under constant axial preload (100-900 N). A significant increase in dissipated energy was observed with increasing cartilage defect size and axial load (p0.073), while all other defect conditions were significantly different (p=0.015). All defect sizes were significantly different (p=0.049) at 900 N axial load. We conclude that the method introduced here could be an alternative for the study of cartilage damage, and further applications based on the principles of this method could be developed for the evaluation of different cartilage treatments.

11 January 2020 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
CWChristian Walter
Christian Walter
ABAlexander Beck
Alexander Beck
CJChristopher Jacob
Christopher Jacob
UHUlf Krister Hofmann
Ulf Krister Hofmann
USUlrich Stöckle
Ulrich Stöckle
FSFabian Stuby
Fabian Stuby
Background: Lateral tibial split fractures (LTSF) usually require surgical therapy with screw or plate osteosynthesis. Excellent anatomical reduction of the fracture is thereby essential to avoid post-traumatic osteoarthritis. In clinical practice, a gap and step of 2 mm have been propagated as maximum tolerable limit. To date, biomechanical studies regarding tibial fractures have been limited to pressure measurement, but the relationship between dissipated energy (DE) as a friction parameter and reduction accuracy in LTSF has not been investigated. In past experiments, we developed a new method to measure DE in ovine knee joints. To determine weather non-anatomical fracture reduction with lateral gap or vertical step condition leads to relevant changes in DE in the human knee joint, we tested the applicability of the new method on human LTSFs and investigated whether the current limit of 2 mm gap and step is durable from a biomechanical point of view.Methods: Seven right human, native knee joint specimens were cyclically moved under 400 N axial load using a robotic system. During the cyclic motion, the flexion angle and the respective torque were recorded and the DE was calculated. First, DE was measured after an anterolateral approach had been performed (condition “native”). Then a LTSF was set with a chisel, reduced anatomically, fixed with two set screws and DE was measured (“even”). DE of further reductions was then measured with gaps of 1 mm and 2 mm, and a 2 mm step down or a 2 mm step up was measured.Results: We successfully established a measurement protocol for DE in human knee joints with LTSF. While gaps led to small though statistically significant increase (1 mm gap:ΔDE compared with native = 0.030 J/cycle, (+ 21%),p = 0.02; 2 mm gap:ΔDE = 0.032 J/cycle, (+ 22%),p = 0.009), this increase almost doubled when reducing in a step-down condition (ΔDE = 0.058 J/cycle, (+ 56%),p = 0.042) and even tripled in the step-up condition (ΔDE = 0.097 J/cycle, (+ 94%),p = 0.004).Conclusions: Based on our biomechanical findings, we suggest avoiding step conditions in the daily work in the operating theatre. Gap conditions can be handled a bit more generously.

1 January 2014 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
EBEvgenij Bobrowitsch
Evgenij Bobrowitsch
ALAndrea Lorenz
Andrea Lorenz
NWNikolaus Wülker
Nikolaus Wülker
CWChristian Walter
Christian Walter
Robots are very useful tools in orthopedic research. They can provide force/torque controlled specimen motion with high repeatability and precision. A method to analyze dissipative energy outcome in an entire joint was developed in our group. In a previous study, a sheep knee was flexed while axial load remained constant during the measurement of dissipated energy. We intend to apply this method for the investigation of osteoarthritis. Additionally, the method should be improved by simulation of in vivo knee dynamics. Thus, a new biomechanical testing tool will be developed for analyzing in vitro joint properties after different treatments. Discretization of passive knee flexion was used to construct a complex flexion movement by a robot and simulate altering axial load similar to in vivo sheep knee dynamics described in a previous experimental study. The robot applied an in vivo like axial force profile with high reproducibility during the corresponding knee flexion (total standard deviation of 0.025 body weight (BW)). A total residual error between the in vivo and simulated axial force was 0.16 BW. Posterior-anterior and medio-lateral forces were detected by the robot as a backlash of joint structures. Their curve forms were similar to curve forms of corresponding in vivo measured forces, but in contrast to the axial force, they showed higher total standard deviation of 0.118 and 0.203 BW and higher total residual error of 0.79 and 0.21 BW for posterior-anterior and medio-lateral forces respectively. We developed and evaluated an algorithm for the robotic simulation of complex in vivo joint dynamics using a joint specimen. This should be a new biomechanical testing tool for analyzing joint properties after different treatments.