Hani Tohme

Dr. Hani Tohme


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2023 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
HTHani Tohme
Hani Tohme
GLGhida Lawand
Ghida Lawand
MCMaja Chmielewska
Maja Chmielewska
JMJoseph Makhzoume
Joseph Makhzoume

12 May 2025 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
GLGhida Lawand
Ghida Lawand
HTHani Tohme
Hani Tohme
LALuis Azevedo
Luis Azevedo
WMWilliam Martin
William Martin
LGLuiz Gonzaga
Luiz Gonzaga
MRMarta Revilla-León
Marta Revilla-León

22 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HTHani Tohme
Hani Tohme
GLGhida Lawand
Ghida Lawand
RERita Eid
Rita Eid
Khaled E AhmedKhaled E Ahmed
Khaled E Ahmed
ZSZiad Salameh
Ziad Salameh
JMJoseph Makzoume
Joseph Makzoume
(1) Background: Stereophotogrammetry has recently been investigated showing high accuracy in complete implant supported cases but has scarcely been investigated in cases of tilted implants. The aim of this in vitro study was to compare the accuracy of digital impression techniques (intraoral scanning and photogrammetry) at the level of intraoral scan bodies in terms of angular deviations and 3D discrepancies. (2) Methods: A stone master cast representing an edentulous maxilla using four implant analogs was fabricated. The two anterior implants were parallel to each other, and the two posterior implants were at an angulation of 17 degrees. Digital intraoral scanning (DIOS) impressions were taken after connecting implant level scan bodies to the master cast and STL files were exported (n = 15). Digital photogrammetry (DPG) impressions were captured using a PiC Camera after tightening implant level PiC optical markers and STL files were exported (n = 15). Superimposition was carried out by a software for determining the accuracy of both. (3) Results: Significant angular discrepancies (ΔA) and 3D deviations of scan bodies were found among the groups in trueness with lower deviations for the DPG (p value < 0.001). However, trueness within ISBs varied between angular and 3D deviations and outcomes were not specific to determine the effect of implant angulation. In precision, no significant differences were detected within ISBs and among both groups in terms of angular deviation. However, DPG had less deviations than DIOS group in terms of 3D deviations (p value < 0.001). (4) Conclusion: Digital photogrammetry technique conveyed the utmost accuracy in both trueness and precision for the intraoral scan bodies among both impression methods assessed. In addition, implant angulation did not influence the precision of the impression techniques but affected their trueness without explicit conclusions.

19 October 2022 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Closed access
CKCynthia Kassis
Cynthia Kassis
Carina MehannaCarina Mehanna
Carina Mehanna
PKPierre Khoury
Pierre Khoury
HTHani Tohme
Hani Tohme
Carlos Cuevas-SuárezCarlos Cuevas-Suárez
Carlos Cuevas-Suárez
Louis Saba HardanLouis Saba Hardan
Louis Saba Hardan

7 October 2025 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
GLGhida Lawand
Ghida Lawand
LGLuiz Gonzaga
Luiz Gonzaga
Julien IssaJulien Issa
Julien Issa
MRMarta Revilla-León
Marta Revilla-León
HTHani Tohme
Hani Tohme
WMWilliam Martin
William Martin

21 February 2024 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
HTHani Tohme
Hani Tohme
MRMarta Revilla-León
Marta Revilla-León
LSLayal Bou Semaan
Layal Bou Semaan
GLGhida Lawand
Ghida Lawand