Cynthia Kassis

Cynthia Kassis


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2020 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
CKCynthia Kassis
Cynthia Kassis
PKPierre Khoury
Pierre Khoury
Carina MehannaCarina Mehanna
Carina Mehanna
NBNadim Z Baba
Nadim Z Baba
FCFadi Bou Chebel
Fadi Bou Chebel
LHLouis Hardan
Louis Hardan

13 August 2021 in Polymers
Verified
Journal Article
Open access
PDF file
GIGeorgi Iliev
Georgi Iliev
Louis Saba HardanLouis Saba Hardan
Louis Saba Hardan
CKCynthia Kassis
Cynthia Kassis
Rim BourgiRim Bourgi
Rim Bourgi
Carlos Cuevas-SuárezCarlos Cuevas-Suárez
Carlos Cuevas-Suárez
Naji KharoufNaji Kharouf
Naji Kharouf
This paper presents state of the art universal adhesive systems and the effect of shelf-life and storage conditions on their bond performance. Three topics are explored in this review: an introduction to the topic, the mechanisms responsible for the degradation of the hybrid layer, and the factors that play a role in the stability of universal adhesives. In addition, issues such as potential durability and clinical importance are discussed. Universal adhesive systems are promising but must be handled and stored according to the manufacturer’s instructions, with careful attention given to the details of shelf-life and storage conditions for maximal success. It appears that the components of universal adhesives play an important role in their stability. Furthermore, HEMA-free formulations using methacrylamides lead to longer shelf-life. Further research is needed to prove these hypotheses.

9 November 2021 in Polymers
Verified
Journal Article
Open access
PDF file
JAJoseph Assaf
Joseph Assaf
Louis Saba HardanLouis Saba Hardan
Louis Saba Hardan
CKCynthia Kassis
Cynthia Kassis
Rim BourgiRim Bourgi
Rim Bourgi
WDWalter Devoto
Walter Devoto
Monika Lukomska-SzymanskaMonika Lukomska-Szymanska
Monika Lukomska-Szymanska
The mechanical properties and the thickness of the resin cement agents used for bonding inlay bridges can modify the clinical performance of the restoration such as debonding or prosthetic materials fracture. Thus, the aim of this study was to evaluate the stress distribution and the maximum strain generated by resin cements with different elastic moduli and thicknesses used to cement resin-bonded fixed partial denture (RBFPD). A three-dimensional (3D) finite element analysis (FEA) was used, and a 3D model was created based on a Cone-Beam Computed Tomography system (CBCT). The model was analyzed by the Ansys software. The model fixation occurred at the root of the abutment teeth and an axial load of 300 N was applied on the occlusal surface of the pontic. The highest stress value was observed for the Variolink 0.4 group (1.76 × 106 Pa), while the lowest was noted for the Panavia 0.2 group (1.07 × 106 Pa). Furthermore, the highest total deformation value was found for the Variolink 0.2 group (3.36 × 10−4 m), while the lowest was observed for the Panavia 0.4 group (2.33 × 10−4 m). By means of this FEA, 0.2 mm layer Panavia F2.0 seemed to exhibit a more favorable stress distribution when used for cementation of posterior zirconium-dioxide-based RBFPD. However, both studied materials possessed clinically acceptable properties.

1 February 2013 in Journal of Oral Implantology
Verified
Journal Article
Closed access
JBJoseph Bassil
Joseph Bassil
NNNada Naaman
Nada Naaman
RLRaed Lattouf
Raed Lattouf
CKCynthia Kassis
Cynthia Kassis
SCSylvie Changotade
Sylvie Changotade
GGGaston Godeau
Gaston Godeau
The aim of the present study was to evaluate bone formation after maxillary sinus augmentation using bovine bone substitute material Bio-Oss alone by means of clinical, histological, and histomorphometrical examination of human biopsies. Deproteinized bovine bone (DPBB, Bio-Oss) was used to fill cavities after elevation of the sinus mucosa following major sinus pneumatization. Twenty patients with edentulous posterior maxillae were treated with 20 sinus augmentation procedures using a 2-stage technique. Residual lateral maxillary bone height was less than 3 mm. Forty-nine Straumann endosseous implants were used to complete the implant-prosthetic rehabilitation. Forty cylinder-shaped bone biopsies were taken from the augmented maxillary region 8 months after grafting during the second-stage surgery before implant placement. All implants were loaded 3 months after insertion, and no failures were recorded. Histomorphometrical analysis showed an average percentage of newly formed bone of 17.6% (±2.8%) and a proportion of residual bone substitute material of 29.9% (±4.9%) of the total biopsy area. Intimate contact between newly formed bone and Bio-Oss was detected along 28.2% (±6.8%) of the particle surfaces. The results also showed that in all cases, the DPBB granules had been interconnected by bridges of vital newly formed bone. Inorganic bovine bone appears to be biocompatible and osteoconductive, and it can be used with success as a bone substitute in maxillary sinus augmentation procedures.

28 September 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Rim BourgiRim Bourgi
Rim Bourgi
Louis Saba HardanLouis Saba Hardan
Louis Saba Hardan
Carlos Cuevas-SuárezCarlos Cuevas-Suárez
Carlos Cuevas-Suárez
WDWalter Devoto
Walter Devoto
CKCynthia Kassis
Cynthia Kassis
Youssef HaikelYoussef Haikel
Youssef Haikel
One of the major goals of adhesive dentistry is to improve the interaction of the already-existing adhesives with different substrates by using different application techniques. Thus, the objective of the present in vitro study was to assess the bond performance of four adhesive systems, Prime&Bond Universal (PBU), Clearfil SE Bond (CSE), OptiBond Universal (OBU), and OptiBond FL (OBFL), to dentin using various application modes: passive application (PA), active application (AA), Compo-Vibes modified application (CVM), and Compo-Vibes application (CV). Eighty extracted human molars were allocated into four groups based on the application modalities tested. The micro-tensile bond strength as well as fracture mode were tested in accordance with ISO/TS 11.405 after 24 h and 6 months of aging. Adhesive contact angle (CA) and scanning electron microscope analysis were also performed (n = 3). Statistical tests were performed with α = 0.05. After 24 h, a significant difference with a higher bond strength value was found for PBU in the AA modality and for CSE in the CVM modality (p < 0.05). However, no significant difference was shown between the techniques used among the other adhesives (OBFL and OBU). Moreover, at 24 h, only the PA demonstrated significant differences between the tested materials (p < 0.05). After 6 months, CSE, PBU, and OBU demonstrated significant differences between the techniques (p < 0.05), with a higher bond strength for CSE in AA and CVM modalities, for PBU in AA modality, and for OBU in AA and PA modalities. No significant differences were found between the techniques used among the OBFL (p > 0.05). In addition, only the CVM technique demonstrated significant differences between the tested materials after 6 months. CV and CVM showed a decreased value after aging for CSE and PBU, respectively. However, all the modalities decreased for OBU and OBFL after aging. All the adhesives showed marked resin infiltration into dentinal tubules in AA among all the modalities tested. Both universal adhesive systems (OBU and PBU) demonstrated statistically lower CA when compared to the other systems (CSE and OBFL) (p < 0.05) when applied in the PA mode. Concerning the AA mode, only CSE and OBFL were tested. The AA demonstrated lower CA values compared to the same adhesives in PA (p < 0.05). It could be concluded that the bond strength could be influenced by both materials and application techniques. It seems that the AA technique could be recommended as a gold standard for the application of an adhesive system to dentin. Plus, the CV and CVM modalities after 6 months of aging were considered stable for PBU and CSE, respectively. Consequently, the performance of these adhesive systems might vary when applied to other modalities. Future studies are needed to test this hypothesis.

19 October 2022 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Closed access
CKCynthia Kassis
Cynthia Kassis
Carina MehannaCarina Mehanna
Carina Mehanna
PKPierre Khoury
Pierre Khoury
HTHani Tohme
Hani Tohme
Carlos Cuevas-SuárezCarlos Cuevas-Suárez
Carlos Cuevas-Suárez
Louis Saba HardanLouis Saba Hardan
Louis Saba Hardan