Background: Lead-related tricuspid valve dysfunction (LDTVD) has not been studied in a large population and its management remains controversial. Methods: An analysis of the clinical data of 2678 patients undergoing transvenous lead extraction (TLE) in years 2008–2021 was conducted, with a separate group of 119 patients with LDTVD. Potential risk factors for LDTVD, improvement in valve function, and long-term prognosis after TLE were assessed. Results: LDTVD was diagnosed in 4.44% of patients referred for lead extraction due to different reasons. The most common mechanism of LDTVD was propping upward or clamping down the leaflet by the lead (85.71%). The probability of LDTVD was higher in female sex, patients with valvular heart disease, atrial fibrillation, heart failure, large right ventricle and high pulmonary artery systolic pressure, the presence of only pacing lead, and in case of collision of the lead with tricuspid valve and adhesion of the lead to the heart structures. The prognosis of patients with LDTVD was worse, however, patients with improved valve function after TLE showed a significantly better long-term survival. Conclusions: Lead dependent tricuspid valve dysfunction is a potentially serious condition that requires thorough diagnostics and thoughtful management. The risk factors for LDTVD are primarily related to the course of the lead and its adhesion to the heart structures. Improvement of tricuspid valve function after TLE is observed in 35.29% of patients Patients with LDTVD have a worse long-term survival, but the improvement in valve function following TLE contributes to a significant reduction in mortality.
Background: Damage to the tricuspid valve (TVD) is now considered either a major or minor complication of the transvenous lead extraction procedure (TLE). As yet, the risk factors and long-term survival after TLE in patients with TVD have not been analyzed in detail. Methods: This post hoc analysis used clinical data of 2631 patients (mean age 66.86 years, 39.64% females) who underwent TLE procedures performed in three high-volume centers. The risk factors and long-term survival of patients with worsening tricuspid valve (TV) function after TLE were analyzed. Results: In most procedures (90.31%), TLE had no negative influence on TV function, but in 9.69% of patients, a worsening of tricuspid regurgitation (TR) to varying degrees was noted, including significant dysfunction in 2.54% of patients. Risk factors of TLE relating to severe TVD were: TLE of pacing leads (5.264; p = 0.029), dwell time of the oldest extracted lead (OR = 1.076; p = 0.032), strong connective scar tissue connecting a lead with tricuspid apparatus (OR = 5.720; p < 0.001), and strong connective scar tissue connecting a lead with the right ventricle wall (OR = 8.312; p < 0.001). Long-term survival (1650 ± 1201 [1–5519] days) of patients with severe TR was comparable to patients without tricuspid damage related to TLE. Conclusions: Severe tricuspid valve damage related to TLE is relatively rare (2.5%). The main risk factors for the worsening of TV function are associated with a longer lead dwell time (more often the pacing lead), causing stronger connective tissue scars connecting the lead to the tricuspid apparatus and right ventricle. TVD is unlikely to affect long-term survival after TLE.
Background: Transvenous lead extraction (TLE) is a relatively safe procedure, but it may cause severe complications such as cardiac/vascular wall tear (CVWT) and tricuspid valve damage (TVD). Methods: The risk factors for CVWT and TVD were examined based on an analysis of data of 1500 extraction procedures performed in two high-volume centers. Results: The total number of major complications was 33 (2.2%) and included 22 (1.5%) CVWT and 12 (0.8%) TVD (with one case of combined complication). Patients with hemorrhagic complications were younger, more often women, less often presenting low left ventricular ejection fraction (LVEF) and those who received their first cardiac implantable electronic device (CIED) earlier than the control group. A typical patient with CVWT was a pacemaker carrier, having more leads (including abandoned leads and excessive loops) with long implant duration and a history of multiple CIED-related procedures. The risk factors for TVD were similar to those for CVWT, but the patients were older and received their CIED about nine years earlier. Any form of tissue scar and technical problems were much more common in the two groups of patients with major complications. Conclusions: The risk factors for CVWT and TVD are similar, and the most important ones are related to long lead dwell time and its consequences for the heart (various forms of fibrotic scarring). The occurrence of procedural complications does not affect long-term survival in patients undergoing lead extraction.
(1) Background: Transvenous lead extraction (TLE) can become far more complex when unanticipated difficulties arise. The aim was to develop a simple scoring system that allows for the prediction of the difficulty and complexity of this significant procedure. (2) Methods: Based on analysis of 3741 TLE procedures with and without complicating factors (extended fluoroscopy time, need for second-line instruments, and advanced techniques and instruments), a five-point Complex Indicator of Difficulty of (TLE) Procedure (CID-TLEP) scale was developed. Two or more points on the CID-TLEP scale indicate a higher level of procedure complexity. (3) Results: Patient age below 51 years at first CIED implantation, number of abandoned leads, number of previous procedures, passive fixation and multiple leads to be extracted, and a ratio of dwell time of oldest lead to patient age during TLE of >0.13 are significant predictors of higher levels of lead extraction complexity. The ROC analysis demonstrates that a point total (being the sum of the odds ratios of the above variables) of >9.697 indicates a 21.83% higher probability of complex TLE (sensitivity 74.08%, specificity 74.46%). Finally, a logistic function was calculated, and we constructed a simple equation for lead extraction complexity that can predict the probability of a difficult procedure. The risk of complex extraction (as a percentage) is calculated as [1/(1 + 55.34 · 0.754X)] · 100 (p < 0.001). (4) Conclusion: The LECOM score can effectively predict the risk of a difficult transvenous lead extraction procedure, and predicting the probability of a more complex procedure may help clinicians in planning lead removal and improving patient management.
Background: Transvenous lead extraction (TLE) is the preferred management strategy for complications related to cardiac implantable electronic devices. TLE sometimes can cause serious complications. Methods: Outcomes of TLE procedures using non-powered mechanical sheaths were analyzed in 1500 patients (mean age 68.11 years; 39.86% females) admitted to two high-volume centers. Results: Complete procedural success was achieved in 96.13% of patients; clinical success in 98.93%, no periprocedural death occurred. Mean lead dwell time in the study population was 112.1 months. Minor complications developed in 115 (7.65%), major complications in 33 (2.20%) patients. The most frequent minor complications were tricuspid valve damage (TVD) (3.20%) and pericardial effusion that did not necessitate immediate intervention (1.33%). The most common major complication was cardiac laceration/vascular tear (1.40%) followed by an increase in TVD by two or three grades to grade 4 (0.80%). Conclusions: Despite the long implant duration (112.1 months) satisfying results without procedure-related death can be obtained using mechanical tools. Lead remnants or severe tricuspid regurgitation was the principal cause of lack of clinical and procedural success. Worsening TR(Tricuspid regurgitation) (due to its long-term consequences), but not cardiac/vascular wall damage; is still the biggest TLE-related problem; when non-powered mechanical sheaths are used as first-line tools.
Background: our knowledge of lead-related venous stenosis/occlusion (LRVSO) remains limited and there is still controversy regarding the risk factors for LRVSO. Venography is mandatory before transvenous lead extraction (TLE). Methods: we performed a retrospective analysis of venograms in 2909 patients (39.43% females, average age 66.90 years) who underwent TLE between 2008 and 2021 at high-volume centers. Results: the severity of LRVSO was likely to be dependent on the number of leads in the system (OR = 1.345; p = 0.003), the number of abandoned leads (OR = 1.965; p < 0.001), the presence of coronary sinus leads (OR = 1.184; p = 0.056), male gender (OR = 1.349; p = 0.003) and patient age at first CIED implantation (OR = 1.008; p = 0.021). The presence of permanent atrial fibrillation (OR = 0.666; p < 0.001) and right ventricular diastolic diameter (OR = 0.978; p = 0.006) showed an inverse correlation with the degree of LRVSO. The combined three-model multivariate analysis provided better prediction of LRSVO using the above-mentioned factors than the CHA2DS2-VASc score. Conclusions: the severity of LRVSO is probably dependent on the mechanical impact of the implanted/abandoned leads on the vein wall, therefore the study has demonstrated the central role of system-/procedure-related risk factors. The thrombotic mechanism may be less important, especially long after implantation, and for this reason the combined prediction model for LRVSO in this study was more effective than the CHA2DS2-VASc score.